Maintenance methods and precautions of Henan fireproof door Maintenance methods and precautions of Henan fireproof door: 1. Door leaf and door frame shall be placed horizontally and stacked indoors with backing plates, and the frame and door leaf shall be stacked separately. 2. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 3. It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 4. Try to avoid outdoor sunshine for a long time to prevent the fire door from being heated. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. supply Steel Grade A fireproof door After splashing with water, wipe it with dry cloth to avoid local expansion. 6. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. 7. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. 8. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 9. Do not support the door for a long time without closing it, which will damage the door closer and make it lose its function. 10. Do not pull off the fireproof seal, or it will lose its function in case of fire. 11. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 12. When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. 13. The fire door closer must be replaced in case of oil leakage. Steel Grade A fireproof door Manufacturer Then, the Henan Fireproof Doors and Windows Editor summarized the above contents into the following points, and you must remember! Do not always open: it is prohibited to manually keep the normally closed fire doors set on the evacuation walkway, the front room of the smoke proof staircase or the shared front room open during the use process to become "normally open" fire doors. In case of a fire, such "normally open" fire doors can not prevent smoke and fire; Regular inspection: frequently check the integrity of the fire door, check whether the door closer and sequencer are in good use, whether the fire door can be closed automatically in order, and whether the screws on the hinge and hinge are loose. If damaged, immediately organize maintenance; Decoration: one-sided pursuit of decoration effect, canceling the fire door frame and setting only the door pocket made of ordinary wood, replacing the original frame of the door leaf with other materials, and adding decorative surface layer in a large range, thus damaging the fire retardant coating and failing to achieve fire retardant effect; Regular test: the normally open fire door shall be tested regularly to check whether its self closing control system, door closer, sequencer, release switch and other aspects are easy to use, whether it can effectively perform the self closing function in case of fire, and at the same time, it is necessary to resolutely prevent the random stacking of articles near the normally open fire door.

What are the requirements for the width of the door of Henan Refuge Room? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings: for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be set with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The [] of the room should adopt the Z-grade fire door, and the fire resistance integrity of the outer window should not be less than 1.00h. supply Steel Grade A fireproof door The total net width of the door, emergency exit, evacuation walkway and evacuation staircase of the residential building with the door of Henan refuge room shall be determined by calculation, and the net width of the door, emergency exit and evacuation staircase shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. Steel Grade A fireproof door Manufacturer The relevant requirements of the Code for Fire Protection Design of Buildings stipulate that: 1. For the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 evacuation [] or emergency exits in buildings of Class I and II fire resistance rating, the straight-line distance from any point of the interior to the evacuation door] or the emergency exit shall not be more than 30 m.

What are the requirements for the opening direction of the door of Henan Refuge Room? Fire doors play an important role in life. The opening direction of fire doors is very important. The Code for Fire Protection Design of Tall Buildings has clearly stipulated that the stairwell should be opened in the direction of evacuation, such as the stairwell should be opened in the direction of the staircase lobby, so as to facilitate the evacuation of people. supply Steel Grade A fireproof door In addition, the front room is generally a place of refuge and an evacuation passageway. In case of a fire, positive pressure air supply is required. If it is not installed in the above opening direction, the air pressure may open the fire door, causing fire and smoke leakage. 4. Classification 4.1 According to the number of door leaves, there are steel single fire door and steel double fire door. 4.2 According to the door leaf structure, there are steel fire door with glass lining, steel fire door without glass lining, steel fire door with bright window and steel fire door without bright window. Steel Grade A fireproof door Manufacturer According to the fire resistance limit, there are Class A fire doors, Class B fire doors and Class C fire doors.

The introduction of Henan fire rolling shutter door is a kind of fire prevention and heat insulation facilities suitable for large openings of buildings. The product has played a certain role in the design and installation of technology. supply Steel Grade A fireproof door Fire resistant rolling shutter doors are widely used in the fire partition area of industrial and civil buildings, which can effectively prevent the spread of fire and ensure the safety of life and property. They are indispensable fire prevention facilities in modern buildings. Installation requirements and instructions for fire shutter door 1. The upper part of the opening where the shutter door is installed shall not be equipped with ventilation pipes, water pipes, etc; 2. After the roller shutter door is installed, install the suspended ceiling. The edge of the suspended ceiling should be 50mm away from the curtain plate to avoid friction; 3. During commissioning and use, it is strictly prohibited to stand at the bottom. Steel Grade A fireproof door Manufacturer Electrical facilities shall not be removed without authorization; 4. According to the fire management regulations, the chain lubricating oil of the starting motor must not be missed during the routine fire safety inspection every quarter, which is also an important part of the omission of many property management units or fire protection units during the inspection.