Henan fire door selection method Fire door is particularly important as a family fire protection, but when you buy low-quality fire door, the fire door is no longer fireproof, what should you do? The fire department of our city investigated and destroyed a batch of inferior fire doors with honeycomb paper instead of fireproof filler materials. Here, the firefighters introduced some tips on how to select and purchase high-quality fire doors. According to the regulations, steel and wood fire doors can be divided into Class A, Class B and Class C according to the fire resistance limit. The fire resistance limit requirements are 90 minutes, 60 minutes and 30 minutes respectively. In addition, the wood used to make wood fire doors needs drying and flame retardant treatment, and the hardware used must also be fire hardware. major Steel Grade A fireproof door There are five ways to choose high-quality fire doors: one is to check the appearance, high-quality steel fire doors are firmly welded, and the welding spots are evenly distributed; The external surface shall be sprayed flat and smooth; There shall be product mark, quality inspection mark and quality certification (approval) mark at the specified position. Steel Grade A fireproof door Manufacturer The qualified wooden fireproof door shall be intact without damage, and the surface shall be clean without plane marks, burrs and hammer marks; Corner cutting and butt joint shall be tight and flat. The second way is to check the figures. The overall dimensions of qualified products should be less than or equal to the overall dimensions in the sample description, the door leaf thickness should be greater than or equal to the door leaf thickness in the sample description, the door frame sidewall width should be greater than or equal to the door frame sidewall width in the sample description, and the overall dimensions of fire-resistant glass should be less than or equal to the overall dimensions of fire-resistant glass in the sample description, The thickness of fireproof glass shall be equal to or greater than the thickness of fireproof glass in the sample description.

The advantages and problems in the development of fire doors in Henan Province Fire doors are more popular in recent years, so how much do you know about the maintenance, advantages and development of fire doors? The following section will provide you with a comprehensive knowledge of fire doors, so that you can better understand fire doors. major Steel Grade A fireproof door Fireproof door is a kind of movable fireproof partition. In addition to the function of ordinary door, it, together with the frame, can meet the requirements of fire resistance stability and integrity within a certain period of time. It has special functions of fire prevention, smoke separation and high temperature blocking. In case of fire, it should have self closing and signal feedback functions. (1) Advantages of fire doors In case of fire, Henan fire doors and windows can be automatically closed through the linkage control system when they are in the open shoulder state, effectively ensuring the reliable closing of fire door maintenance in the fire, so as to achieve its due role in smoke separation and fire resistance. There is no big difference between the maintenance of fire doors and the maintenance of normally closed fire doors in terms of production and basic configuration, but the door closers for the maintenance of normally closed fire doors are replaced with automatic fire release devices that are linked with the automatic fire alarm. At the same time, they can be installed with the control box produced by the manufacturer. Linkage is achieved by installing smoke detectors and smoke detectors on the left and right sides of the maintenance of fire doors, When the smoke detector detects the smoke signal and sends it to the host computer of the automatic fire alarm linkage control system, the linkage control system transmits 24v power to the fire door maintenance releaser to automatically close the fire door for maintenance. The closing or opening status of the fire door maintenance has signals fed back to the alarm host computer or control box. Steel Grade A fireproof door Manufacturer The automatic release device for fire door maintenance developed by Dong Shicong of Chengdu Huili University Research Institute can open the fire door maintenance for 0-180 degrees freely and close it smoothly, completely changing the disadvantage of inconvenient use of the normally closed fire door maintenance closer due to its large opening angle of 90 degrees, and once the fire door is closed for maintenance, the release device will not be reset, It has become a movable fire door maintenance that automatically opens, closes, opens and closes, overcoming the contradiction that normally closed fire doors must be manually closed or cannot be closed after being pushed to a certain limit (greater than 90 degrees) for maintenance; The lesson of blood proves that people who escape from a fire simply cannot close the opened fire door for maintenance due to panic and eagerness to escape.

What is the standard of Henan refuge door? Requirements for fire protection structure: 1) The floor of the evacuation floor must be cast-in-place reinforced concrete floor, and the fire resistance must be 2.00h or higher. major Steel Grade A fireproof door It is necessary to provide insulation on the floor. The fire resistance of the walls around the evacuation floor and the bulkheads in the evacuation floor shall not be less than 3.00h, and the bulkhead doors must be fire doors. Henan refuge bay door 2. As the equipment floor: 1) Gather various equipment and pipeline shafts into compartments. The flammable and combustible liquid or gas pipeline shall be located in the center, and the equipment pipeline area shall be separated from the fire prevention area and evacuation area. The fire prevention limit of the firewall is 3.00h or more. 2) The pipe shaft and machine room must be separated from the evacuation area, and the fire partition with a fire limit of 2.00h or more shall be used. Pipeline wells and equipment doors shall not be opened directly to the evacuation area. Steel Grade A fireproof door Manufacturer If you really need to enter the evacuation place, the distance from the entrance to the evacuation place must be at least 5m, and fire doors must be used in the evacuation room.

Henan fireproof door is generally set in the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Inspection doors of vertical pipe shafts such as cable shafts, pipe shafts, smoke exhaust ducts, garbage ducts, etc. Henan fire door (3) divides the fire compartment, controls the fire wall and the door on the fire partition of the building area of the compartment. major Steel Grade A fireproof door When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (4) Code (such as GB50016-2014 Code for Fire Protection Design of Buildings) or partition door with special requirements for fire and smoke prevention. For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. Steel Grade A fireproof door Manufacturer There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. Fire and burglar proof doors are often used as household doors in high-rise and high-grade residential buildings. GB 12955-2008 Requirements for Fire Resistance of Fire Doors Fire doors are an important part of fire fighting equipment and an important part of social fire prevention. Fire doors should be equipped with fire door closers or door closers that allow normally open fire doors to automatically close the door leaves in case of fire (except for special parts, such as pipeline shaft doors, etc.). That is to say, except for some special parts, such as pipeline well doors, which do not need to install door closers, other parts need to install fire door closers.

The main difference between Henan fireproof door and anti-theft door is that the anti-theft door has a good anti prying sealing performance. Generally, the door cannot be opened without a key after closing the door, and the filler in the door panel is not fireproof material. The security door must be marked with "FAM" and refer to the general technical conditions of security door GB17565-2007. Although the fireproof door is also made of steel, the door plate is filled with fireproof materials, and the thickness of the door plate also has different requirements. The steel door is an ordinary steel door. It also has a certain anti-theft function, but its anti prying performance is relatively poor. This type is common in street processing plants. major Steel Grade A fireproof door Only Shanghai and Chengdu have local standards for fire and burglar proof doors, and those in other places can only be called fire entry doors, that is, fire doors that reach the standard of fire rated A or B, and (filled with fire door cores) Class A and B standards are generally divided by fire resistance time. At the same time, it meets the anti prying requirements in the following aspects: the door frame is 1.5 thick, and the steel plates on the front and back of the door leaf are 0.8 thick. The lock has the anti prying function, that is, the lock body has both an oblique locking tongue and a square locking tongue. It has the function of quick opening. It is a good twist type, but it is not allowed to install a heaven and earth lock. Locks and cat eyes shall be provided with fire detection reports. Class B fire doors can be fitted with door collars, while Class A fire doors are not allowed. Steel Grade A fireproof door Manufacturer At the time of acceptance, the merchant must provide fire type approval certificate, fire detection report and metal door detection report. Fire detection report of locks and cat's eyes. The door leaf is opened in the direction of rapid evacuation and cannot be opened inward.