
Henan fire door technical requirements Wooden fire door is a door with certain fire resistance performance, which is made of fire-resistant wood or fire-resistant wood products as door frame, door leaf framework, door leaf panel. If the door leaf is filled with materials, it is filled with fire insulation materials that are non-toxic and harmless to human body, and equipped with fire hardware accessories. high quality Fire door The overlapping size of door leaf and door frame shall not be less than 12mm; The fit clearance between the door leaf and the hinge side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The fit clearance between the door leaf and the locked side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The clearance between the door leaf and the upper frame shall not be greater than 3mm; The gap between two or more door leaves shall not be greater than 3mm; The movable clearance between the door leaf and the lower frame or ground shall not be greater than 9mm; The gap between the door leaf and the door frame binding surface: the gap between the door leaf and the binding surface of the door frame on the hinge side, the lock side and the upper frame shall not be greater than 3mm; The plane height difference between the door leaf and the door frame: On the opening surface of the fire door, the plane height difference between the door frame and the door leaf of Tianjin Telescopic Barcode Reader should not be greater than 1mm. Wooden fireproof door refers to the door frame, door leaf framework and door leaf panel made of wood or wood products, and the fire resistance limit of the door reaches the specified value. Some small deviations between wooden fireproof doors cannot be wrong. Maybe it is a small detail problem that may fail to meet the standard. Fire door Manufacturer The materials used for Henan fire door are compared first. The fire door has a simple structure and is mainly composed of four parts: door closer, door panel materials (including 06 and 08), door frame materials, and fire panels. Grade A fireproof door is generally made of 08 material with good quality. Its normal service life is 5-8 years. The iron material of the door panel is thick. For the fireproof door with the same thickness, the weight of Grade A fireproof door is greater than that of Grade B.

The fireproof performance of Henan fireproof door is strong. With the development of the times, the fireproof door made of a kind of wood has played a role in fire prevention after processing. After the emergence of the fireproof door, it has gradually been applied to engineering and civil construction. high quality Fire door Next, the rolling shutter manufacturer will introduce the excellent fire performance of fire doors! In the high-rise and middle residential buildings, fire performance is very critical. As a related fire prevention function, it is better to have a better performance if the commercial house catches fire after installation. During the main use process, the advantages of performance and related fire prevention are also gradually emerging. As long as the fire protection performance is grasped, it is also critical in the safe passage. The key is to comprehensively grasp the advantages of such a fire door. Henan fire door is mandatory in the construction process for fire doors, because it is a kind of safety protection for the public. The quality of this door is very good, and from the appearance, the main thing is to grasp the relevant technology, to better grasp the advantages of this performance, can be used in many buildings, is to get permission, can be better reflected in this fire function. Because in the installation process, the installation is carried out by the relevant regular work installers. Fire door Manufacturer The operation process is also complex. The emergence of this kind of door industry is almost a unified brand everywhere.

Henan fire door development prospects 1. The fire door industry is also an emerging industry, with huge market capacity and market potential. 2. Due to the high qualification threshold of fire doors, there are not many manufacturers that can really enter the fire door industry, but also Grade C fire doors Grade C fire doors Henan fire doors. According to incomplete statistics, there are more than 1000 fire door enterprises. high quality Fire door This does not include those family workshop type processing units. The products produced by these processing units are of different grades, with prices ranging from hundreds to thousands of yuan. 3. The market pattern in the industry has not been formed yet. There are few large enterprises and brands, and there is no leading brand. The research, development and production of fire door products have played a positive role in ensuring the safety of people's lives and property. China's fire door market started late, but developed rapidly. In recent years, some European and American enterprises have actively participated in the competition in the Chinese fire door market, especially European enterprises, which are trying to make European fire doors occupy more of the Chinese market. Fire door Manufacturer In the face of competitors, we must face up to the current situation. On the one hand, we should learn from our competitors modestly, and on the other hand, we should strive to enhance our own strength. Fire door manufacturers in China are facing a huge challenge. Who can seize the opportunity in this challenge will become a winner in the market.

Henan fireproof rolling shutter door maintenance common faults and treatment methods The fireproof rolling shutter door is constantly applied to large supermarkets, shopping malls, underground garages, workshops and other crowded places. It is inevitable that there will be some small problems that need to be solved. I summarize a few points for your reference. 1、 The fire shutter door does not act: first, check the power supply to see if the power supply air switch of the fire shutter door has power. If there is no power, check the power supply. If there is power, the power indicator of the roller shutter control box should be green at this time. high quality Fire door If the indicator light is not on, then we should check whether the transformer in the control box (the resistance of the transformer is 270 ohms) is burned out. If the power indicator flashes green, it indicates that the power supply may be out of phase. If the power supply is not out of phase, it may be that the standby power board of the control box is burned out; It is also possible that both the power board and the standby power board are burned out. 2、 Henan fire shutter door power supply air switch cannot be pushed up: when delivering the gate, the air switch cannot be pushed up, first check whether there is a problem with the standby board, and the resistance of the output line of the standby board is about 300 ohms. In case of open circuit or short circuit, check whether the motor brake is burnt or whether the spare board is burnt. 3、 The operation button does not work properly: you should first press the Stop key, then press the Reset key, and then press the Up and Down keys. 4、 The indicator lights of the power control box or button panel are all on: at this time, first check whether there is a short circuit in the button line or a button may be pressed to death. If the above phenomenon does not exist, it may be that the chip on the power main board is broken, and then replace the chip. Fire door Manufacturer Pay attention to wearing the clothes in reverse (that is, the opening faces the opening).

Maintenance and cultivation of Henan fire rolling shutter All fire rolling shutters should be checked and tested once a week. The test content includes: fire rolling shutter escape function test. high quality Fire door After the fire roller shutter is in the linkage state and drops to the bottom, press any manual button on both sides of the fire roller shutter, and the fire roller shutter shall be able to rise to the limit position (or drop to the bottom again after a delay). The lifting, lowering and stopping test of the manual buttons on both sides of the fire shutter. The fire rolling shutter shall be able to operate according to the instructions, and the operation shall be stable without blocking, not to mention uneven running speed of the shutter, stacking of the shutter or derailment. Test of manual emergency device. The manual zipper is used to lift the fire shutter, and the manual quick release device is used to lower the fire shutter. The fire shutter shall be able to run smoothly. Simulate the fire signal for linkage test. It is required that the fire shutter should be able to descend according to the normal procedure, and the contents and parts displayed in the fire control room should be consistent with the actual situation. Check whether the sealing of fire shutter is intact and damaged. The inspection above Henan fire rolling shutter door shall be carefully recorded, and the problems found shall be solved in a timely manner without leaving hidden dangers. Check whether the appearance of the fire shutter is intact and whether the curtain surface is damaged. Henan fire shutter door The door leaf of Henan fire shutter door cannot move: sensor failure is the major cause of the fire shutter door leaf cannot move. When such a situation occurs, be sure to check whether the sensor signal light is normal. If it is not the fault of the sensor, it may be that the wire connector is loose, the belt falls off, the controller is burned, the foreign matter is stuck, the voltage is abnormal, and so on. Pay attention to check and eliminate them one by one. Fire door Manufacturer The door leaf of the fire rolling shutter jumps when opening and closing: the reason for this fault is very simple. If the track of the fire rolling shutter is jammed by foreign matters, it is necessary to check the tracks on both sides of the door leaf, remove the foreign matters, and the fault can be solved. The opening and closing speed of the fire shutter door leaf is too slow: customers often hear this situation. It may be that the speed adjustment of the national controller is too slow, or the belt is too loose, resulting in friction between the fire shutter door leaf and the guide rail. When handling, check these two parts. If the speed is too slow, adjust them faster. If the belt is too loose, tighten it in time.