The installation of Henan fire rolling shutter door is prone to some problems. One problem is the strength of the transmission device of the fire rolling shutter door. The strength of the roller shutter shaft is also an important parameter of the roller shutter door. At present, there are many unqualified products with this strength, The structure of the roller shutter shaft that seriously affects the use of the fire shutter door mainly refers to the depth of the roller shutter shaft and the shaft heads at both ends plugged into the steel pipe and the depth of the structural shaft head plugged into the steel pipe should be about 110 of the shaft length, and there should be two flanges and enough welds. major Fire resistant roller shutter The second problem is the depth of the guide rail. If the depth of the guide rail is not enough and the structure and materials are improper, once encountering a fire, the door curtain is easy to detach from the guide rail and cannot play a role in fire prevention. Fire resistant roller shutter Manufacturer The third problem is the pre rolling of the fire rolling shutter door. The fire rolling shutter door, especially the steel fire rolling shutter door, is relatively heavy, so a circle of pre rolling will be reserved on the reel to reduce the tension of the curtain weight on the screws. Prevent a curtain from cracking.

Do you know these characteristics of Henan fire rolling shutter door? Fire rolling shutter door is a rolling shutter door used to prevent the spread of fire. It is obviously different from ordinary rolling shutter door. There are also some characteristics that few people know. The manufacturer of fire rolling shutter door will tell you. major Fire resistant roller shutter First of all, the data transmission of the fireproof rolling shutter door is very fast and reliable. Yes, the fireproof rolling shutter door is not the kind of rolling shutter door that can only rise and fall as we see in the street shops. The manufacturer of the fireproof rolling shutter door has installed an integrated bus inside it, so that data can be transmitted. After receiving the fire information, the rolling shutter will immediately conduct automatic information processing and take emergency fire prevention measures. Henan fireproof rolling shutter door Secondly, the fireproof rolling shutter door has standby power supply. In case of a fire, the common power supply is cut off, and the standby power supply can still be opened normally, so as to ensure the lifting of the fireproof rolling shutter door, avoid the danger caused by emergencies, and effectively improve the safety factor. Henan fire shutter door Again, the manufacturer of fire shutter door has installed smoke and temperature sensing devices and equipment for it. Once a fire occurs, the device can quickly distinguish and detect, give an alarm and take fire prevention measures to remind people to control and defend, and reduce safety risks. Fire resistant roller shutter Manufacturer In addition, Henan fire rolling shutter door also has a manual operation device. Generally, the fire rolling shutter door is controlled by the power supply, but in the event of a fire and the power supply is cut off, the controller can automatically identify and quickly drop manually to play the role of fire protection.

Maintenance methods and precautions of Henan fireproof door Maintenance methods and precautions of Henan fireproof door: 1. Door leaf and door frame shall be placed horizontally and stacked indoors with backing plates, and the frame and door leaf shall be stacked separately. 2. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 3. It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 4. Try to avoid outdoor sunshine for a long time to prevent the fire door from being heated. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. major Fire resistant roller shutter After splashing with water, wipe it with dry cloth to avoid local expansion. 6. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. 7. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. 8. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 9. Do not support the door for a long time without closing it, which will damage the door closer and make it lose its function. 10. Do not pull off the fireproof seal, or it will lose its function in case of fire. 11. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 12. When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. 13. The fire door closer must be replaced in case of oil leakage. Fire resistant roller shutter Manufacturer Then, the Henan Fireproof Doors and Windows Editor summarized the above contents into the following points, and you must remember! Do not always open: it is prohibited to manually keep the normally closed fire doors set on the evacuation walkway, the front room of the smoke proof staircase or the shared front room open during the use process to become "normally open" fire doors. In case of a fire, such "normally open" fire doors can not prevent smoke and fire; Regular inspection: frequently check the integrity of the fire door, check whether the door closer and sequencer are in good use, whether the fire door can be closed automatically in order, and whether the screws on the hinge and hinge are loose. If damaged, immediately organize maintenance; Decoration: one-sided pursuit of decoration effect, canceling the fire door frame and setting only the door pocket made of ordinary wood, replacing the original frame of the door leaf with other materials, and adding decorative surface layer in a large range, thus damaging the fire retardant coating and failing to achieve fire retardant effect; Regular test: the normally open fire door shall be tested regularly to check whether its self closing control system, door closer, sequencer, release switch and other aspects are easy to use, whether it can effectively perform the self closing function in case of fire, and at the same time, it is necessary to resolutely prevent the random stacking of articles near the normally open fire door.

A brief talk on the problems encountered in the fire acceptance of Henan fire rolling shutter door 1. The curtain plate coating falls off and rusts, and the curtain plate has obvious pressure pits, concave convex, and penetrating holes. major Fire resistant roller shutter The rolling shutter is a complete fire protection product. If the shutter has problems, it will directly affect the fire resistance limit index of the rolling shutter. 2. The guide rail is deformed and the curtain board is stuck or falls unevenly. The fireproof rolling shutter door generally moves along the guide rail. If the guide rail is twisted or broken, the rolling shutter door will not be able to move to the specified position, which will not achieve the effect of fire separation. 3. On the roller shutter, the lower limit fails or the limit line is wrongly connected. Fire resistant roller shutter Manufacturer This often happens on the fire roller shutter of the atrium. Because the fire roller shutter of the atrium is sometimes installed outside the walkway of the upper floor, there is no floor under the roller shutter to close it, and a large gap is leaked, so the fire separation of the upper and lower floors cannot be reached.

Henan fireproof rolling shutter door is developing rapidly. Henan fireproof rolling shutter door style and measurement design considerations. The fireproof rolling shutter door is widely used in commercial buildings, workshops and underground garages. The specific installation standards are as follows: measurement design: step one: general classification of roller shutter installation. Self inspection of fire shutter: manual operation mode: whether a circular iron chain set in the storage box at one side of the shutter can be found to operate the lowering and rolling. major Fire resistant roller shutter When the installation form is wall side installation: when there are embedded parts (steel plates) in the building, after cleaning the installation datum plane, check and verify whether the size and external position of the embedded parts are suitable for the installation drawing design. If the design requirements are appropriate, this is the datum plane for the installation of large and small supports. Fire resistant roller shutter Manufacturer The facing bricks around the wall projections shall be cut and matched with the whole brick, and the edges shall be clean. (Check the date of delivery and the date of maintenance; carbon dioxide, dry powder and clean gas extinguishers are outdated if they have been delivered for 5 years or maintained for 2 years; foam extinguishers are outdated if they have been delivered for 3 years or maintained for 1 year, and they need to be sent to the fire extinguisher factory or professional maintenance unit for maintenance). Henan fireproof rolling shutter door After the Henan fireproof rolling shutter door is installed, the ceiling edge should be 50mm away from the curtain plate to avoid friction; c. The foundation dimensions of rolling shutter doors and parts shall be measured, which shall be consistent with the requirements of the design institute.

Henan fire door technical requirements Wooden fire door is a door with certain fire resistance performance, which is made of fire-resistant wood or fire-resistant wood products as door frame, door leaf framework, door leaf panel. If the door leaf is filled with materials, it is filled with fire insulation materials that are non-toxic and harmless to human body, and equipped with fire hardware accessories. major Fire resistant roller shutter The overlapping size of door leaf and door frame shall not be less than 12mm; The fit clearance between the door leaf and the hinge side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The fit clearance between the door leaf and the locked side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The clearance between the door leaf and the upper frame shall not be greater than 3mm; The gap between two or more door leaves shall not be greater than 3mm; The movable clearance between the door leaf and the lower frame or ground shall not be greater than 9mm; The gap between the door leaf and the door frame binding surface: the gap between the door leaf and the binding surface of the door frame on the hinge side, the lock side and the upper frame shall not be greater than 3mm; The plane height difference between the door leaf and the door frame: On the opening surface of the fire door, the plane height difference between the door frame and the door leaf of Tianjin Telescopic Barcode Reader should not be greater than 1mm. Wooden fireproof door refers to the door frame, door leaf framework and door leaf panel made of wood or wood products, and the fire resistance limit of the door reaches the specified value. Some small deviations between wooden fireproof doors cannot be wrong. Maybe it is a small detail problem that may fail to meet the standard. Fire resistant roller shutter Manufacturer The materials used for Henan fire door are compared first. The fire door has a simple structure and is mainly composed of four parts: door closer, door panel materials (including 06 and 08), door frame materials, and fire panels. Grade A fireproof door is generally made of 08 material with good quality. Its normal service life is 5-8 years. The iron material of the door panel is thick. For the fireproof door with the same thickness, the weight of Grade A fireproof door is greater than that of Grade B.