What problems should be paid attention to during the installation of Henan fire door? Henan fire door manufacturers should know that the use performance of fire doors comes from the quality problems of the fire doors themselves on the one hand, and the installation of fire doors on the other hand. If the fire doors are not installed according to the relevant standards, then their fire performance may be affected in the use process. major anti-theft door Here are some precautions for installation. 1. When installing door frames and leaves, attention shall be paid to the opening direction of the door, which must be opened in the direction of evacuation. 2. Stealing work and materials is strictly prohibited. Some construction units speed up construction. There are serious problems of cutting work and materials when installing fire doors. Some do not install door closers or sequencers; Some fire doors should be equipped with 3 hinges, and they only have 2 or 1 hinge; Some fireproof door hinges with 4 screw holes are only installed with 2 screws, reducing the fixing strength; Some even install non fireproof hardware fittings and door locks; Some do not install fireproof sealing strips; Some fireproof doors are equipped with ordinary glass or fireproof glass that exceeds the specified area, etc. It is important to know that these jerry building will be reflected in the use of fireproof doors later. anti-theft door Manufacturer Fire doors have special functions of fire prevention, smoke separation, fire spread suppression and evacuation protection, so they should have good airtightness. Therefore, attention should be paid to some details or sealing problems during installation.

In order to protect life and property in time and effectively in case of fire, the fire door of Henan refuge room adopts double-sided fireproof board according to the fire protection design requirements of high-rise building refuge room, so as to achieve dual internal and external fire prevention treatment. The Class A 1.50h and Class B 1.00h fully meet the fire protection requirements, which can strive for greater rescue opportunities for people in case of fire, Make sure there is enough time for rescue. major anti-theft door The fire door of the refuge room is rarely noticed, but it is related to everyone's life safety. When a fire occurs, the fire protection of the refuge bay i] can play the role of fire isolation, isolating the highly toxic smoke and high temperature outside the refuge bay. Provide shelter for people in high-rise buildings and provide more opportunities for emergency rescue. For residential buildings with a building height of more than 54m, each household shall have a refuge room, and the door of the room shall be straight with Class B fireproof door, and the fire resistance integrity of the external window shall not be less than 1.00h. In terms of the current hardbound house configuration in China, a refuge room will be provided for high-rise buildings above 54 meters- The fire resistance limit of the fire door of the general refuge room is about 1h according to the fire control requirements, so that people can escape into the relatively safe environment of the refuge room within one hour of the fire. In recent years, with the growing development of high-rise buildings, skyscrapers have sprung up, and fire doors in shelters have gradually been recognized. anti-theft door Manufacturer In order to meet the requirements of high-end buildings for the fire door of refuge room and the surrounding decoration style. Fire doors in shelters are also new. Style panels are more diverse. It is no longer as rigid and dull as the old fire door.

The main difference between Henan fireproof door and anti-theft door is that the anti-theft door has a good anti prying sealing performance. Generally, the door cannot be opened without a key after closing the door. The filler in the door panel is not fireproof material. major anti-theft door The security door must be marked with "FAM" and refer to the general technical conditions of security door GB17565-2007. Although the fireproof door is also made of steel, the door plate is filled with fireproof materials, and the thickness of the door plate also has different requirements. The steel door is an ordinary steel door. It also has a certain anti-theft function, but its anti prying performance is relatively poor. This type is common in street processing plants. Only Shanghai and Chengdu have local standards for fire and burglar proof doors, and those in other places can only be called fire entry doors, that is, fire doors that reach the standard of fire rated A or B, and (filled with fire door cores) Class A and B standards are generally divided by fire resistance time. At the same time, it meets the anti prying requirements in the following aspects: the door frame is 1.5 thick, and the steel plates on the front and back of the door leaf are 0.8 thick. The lock has the anti prying function, that is, the lock body has both an oblique locking tongue and a square locking tongue. It has the function of quick opening. It is a good twist type, but it is not allowed to install a heaven and earth lock. Locks and cat eyes shall be provided with fire detection reports. Class B fire doors can be fitted with door collars, while Class A fire doors are not allowed. anti-theft door Manufacturer At the time of acceptance, the merchant must provide fire type approval certificate, fire detection report and metal door detection report. Fire detection report of locks and cat's eyes. The door leaf is opened in the direction of rapid evacuation and cannot be opened inward.

The fireproof performance of Henan fireproof door is strong. With the development of the times, the fireproof door made of a kind of wood has played a role in fire prevention after processing. After the emergence of the fireproof door, it has gradually been applied to engineering and civil construction. major anti-theft door Next, the rolling shutter manufacturer will introduce the excellent fire performance of fire doors! In the high-rise and middle residential buildings, fire performance is very critical. As a related fire prevention function, it is better to have a better performance if the commercial house catches fire after installation. During the main use process, the advantages of performance and related fire prevention are also gradually emerging. As long as the fire protection performance is grasped, it is also critical in the safe passage. The key is to comprehensively grasp the advantages of such a fire door. Henan fire door is mandatory in the construction process for fire doors, because it is a kind of safety protection for the public. The quality of this door is very good, and from the appearance, the main thing is to grasp the relevant technology, to better grasp the advantages of this performance, can be used in many buildings, is to get permission, can be better reflected in this fire function. Because in the installation process, the installation is carried out by the relevant regular work installers. anti-theft door Manufacturer The operation process is also complex. The emergence of this kind of door industry is almost a unified brand everywhere.

The operation method of Henan fire doors is recognized by the laboratory of the Ministry of Economy of the Ministry of Fire Protection. According to the new version of the standard for fire doors GB_12955-2008 implemented on January 1, 2009, those who pass the fire resistance test method of fire doors and obtain the registration certificate and authorization mark issued by the Bureau of Standards and Inspection of the Ministry of Economy are called fire doors. major anti-theft door The fire door defined in the American NFPA and IBC codes is "the combination of any fire door leaf, door frame, hardware and other accessories that can jointly provide a certain degree of fire protection at the opening." Operation method Henan fire door widely carries out publicity and education on the use, maintenance and management of fire prevention facilities within the jurisdiction of the fire department in charge, Efforts should be made to improve people's awareness of fire protection and self-protection; Extensive publicity, education and training on fire protection and umbrella protection knowledge shall be carried out for units installed with fire door maintenance, so as to make every employee understand the basic knowledge of the use, maintenance and management of fire door maintenance, and consciously participate in the maintenance and management of the Gate of Life, so as to keep them in a state of combat readiness at all times; The fire door maintenance purpose, function and good use status and basic requirements for use shall be posted on the fire door maintenance, and the words "normally closed fire door maintenance, please close at any time" shall be written on the conspicuous position of the normally closed fire door maintenance, so that customers and the masses can understand the basic knowledge of fire door maintenance. anti-theft door Manufacturer Carry out publicity activities to protect fire-fighting facilities and equipment, and mobilize everyone to participate in the protection of fire-fighting facilities such as fire door maintenance.

The installation and installation of Henan fireproof rolling shutter door requires that the fireproof rolling shutter door is widely used in shopping malls, shopping malls and underground garages, but the specific installation steps should not mention laymen. major anti-theft door Even the fireproof rolling shutter door can not be explained in detail. The following is a detailed description of the installation of Henan fireproof rolling shutter door step by step: step 1: install the guide rail. 1. Determine the installation position of the guide rail on both sides of the fireproof rolling shutter door, set out the guide rail reference line with hammer line, and set out the cross line of the fixing bolt of the guide rail connector. The guide rail is not less than 75cm above the ceiling. 2. Punch the holes for fixing expansion bolts of connectors on the wall column with a percussion drill. The spacing between connectors shall not be more than 600mm, and both ends shall be 100mm away from the guide rail opening. Fix several connecting pieces up and down first, stick the guide rail, correct its verticality and spot weld it, and then repeat the verticality of the guide rail after fixing the guide rail. The verticality of each meter shall not exceed 5mm, and the verticality of the whole length shall not exceed 20mm. The depth of the composite curtain embedded in the guide rail (see GBl4102-2005). 3. Install the rest of the connecting pieces. Spot welding shall be adopted between the connecting piece and the guide rail. The spot welding points between each connecting piece and a guide rail shall not be less than 5 points, and the width of the spot welding shall not be less than 5mm. The welding point shall never be penetrated. anti-theft door Manufacturer Stainless steel welding rod shall be used when stainless steel guide rail is used.