Henan fireproof rolling shutter door is developing rapidly. Henan fireproof rolling shutter door style and measurement design considerations. The fireproof rolling shutter door is widely used in commercial buildings, workshops and underground garages. The specific installation standards are as follows: measurement design: step one: general classification of roller shutter installation. Self inspection of fire shutter: manual operation mode: whether a circular iron chain set in the storage box at one side of the shutter can be found to operate the lowering and rolling. major Steel Grade A fireproof door When the installation form is wall side installation: when there are embedded parts (steel plates) in the building, after cleaning the installation datum plane, check and verify whether the size and external position of the embedded parts are suitable for the installation drawing design. If the design requirements are appropriate, this is the datum plane for the installation of large and small supports. Steel Grade A fireproof door direct deal The facing bricks around the wall projections shall be cut and matched with the whole brick, and the edges shall be clean. (Check the date of delivery and the date of maintenance; carbon dioxide, dry powder and clean gas extinguishers are outdated if they have been delivered for 5 years or maintained for 2 years; foam extinguishers are outdated if they have been delivered for 3 years or maintained for 1 year, and they need to be sent to the fire extinguisher factory or professional maintenance unit for maintenance). Henan fireproof rolling shutter door After the Henan fireproof rolling shutter door is installed, the ceiling edge should be 50mm away from the curtain plate to avoid friction; c. The foundation dimensions of rolling shutter doors and parts shall be measured, which shall be consistent with the requirements of the design institute.

Can the door of Henan Refuge Room be removed? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings, for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be equipped with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The door of the room should be Class B fireproof door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Steel Grade A fireproof door The total net width of each door, emergency exit, evacuation walkway and evacuation staircase of the residential building shall be determined by calculation, and the net width of the door and emergency exit shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation outer door shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. The relevant requirements of the Code for Fire Protection Design of Henan Refuge Room Door Buildings stipulate that: 1. Evacuation in buildings with Class I and II fire resistance rating] or the linear distance from any point in the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 emergency exits to the nearest evacuation] or the emergency exit shall not be more than 30m. 2. When the evacuation door] cannot directly connect to the outdoor ground or the evacuation staircase, an evacuation corridor with a length of no more than 10m shall be used to connect to the nearest emergency exit. Steel Grade A fireproof door direct deal When the place is equipped with automatic sprinkler system, the safe evacuation distance from any indoor point to the near emergency exit can be increased by 25%.

What is the reason why the products of Henan fire shutter manufacturers are popular? Have you heard of fire shutter doors? This is a popular product in warehouses, street shops, garages and other places. It is also the main product of fire shutter manufacturers. major Steel Grade A fireproof door In fact, there are many kinds of rolling shutter doors, but why are fire resistant rolling shutter doors so popular? Henan fire shutter door From the fire shutter door itself, we can see that its design can be accurate to mm. The curtain has 36 colors to choose from, which is very beautiful, durable, high toughness, and excellent corrosion resistance. The fireproof rolling shutter door manufacturer uses 6063t5 fireproof materials to process and make it outstanding in anti strike and anti scratch performance, effectively avoiding malicious intrusion, and making the protection more effective. The manufacturer also uses the electrostatic powder spraying process to treat the exterior, enhance its corrosion resistance, anti-aging, weather resistance, and extend its service life. Steel Grade A fireproof door direct deal The friends who have used ordinary rolling shutter doors in Henan know that rolling shutter doors are made of metal, which will produce noise during operation and affect people's life and work. However, the rolling shutter door produced by the fire shutter door manufacturer uses a silent operation system to reduce noise and reduce the impact on life. Its anti-theft function is more prominent, and its reliable balance system and powerful driving device also make it more lightweight. These advantages are the reasons why it is popular.

Thickness requirements and guide rail problems of Henan fire rolling shutter door For the fire rolling shutter door itself, we will actually notice that it is actually a kind of common fire prevention equipment in buildings, and the thickness of the roller shutter on the fire rolling shutter door in Henan. major Steel Grade A fireproof door First of all, as for the thickness of the curtain, it actually refers to the thickness of a steel plate used for the curtain, which is actually used in practice. In terms of the current form of Henan fire shutter door, for some manufacturers of Henan fire shutter door, there will be a series of problems of jerry building. For many manufacturers, we will actually notice that when they test, they use qualified steel plates, but when they produce, In fact, the steel plate used is relatively thin. When installing this kind of roller shutter, it is not convenient to measure its thickness, so many unqualified products are easy to muddle through. Steel Grade A fireproof door direct deal In this respect, for the materials on the fire shutter door, the fire shutter itself will not meet the requirements. At this time, it will actually reduce its service life and fire resistance time to a certain extent.

Henan fireproof door installation method The fireproof door is divided into steel fireproof door and wooden fireproof door according to the material. There are some differences in the installation method of the two fireproof doors. major Steel Grade A fireproof door The fire rating is slightly different. You must pay attention to the details when installing. First of all, when installing the wooden fireproof door, the size of the door frame should be 20mm smaller than the opening, and the lower foot of the door frame should be buried 20mm below the ground. The door frame should be firmly fixed with the wall, and perpendicular to the corner. The vertical frame and bracing frame shall be straight and at the same angle to avoid planing and sawing. There shall be no less than 3 fixed points on both sides of the door frame, and the spacing shall not be greater than 800mm. Secondly, during the installation of the steel fire door, considering the bending deformation of the door frame, it is necessary to support the door frame with wooden braces in the width direction of the door frame. The lower foot of the door frame is buried 20 mm below the ground, and then the door frame is welded with the embedded parts on the wall. Then make a hole in the wall at the upper corner of the door frame, and pour concrete of cement, sand and expanded perlite (1:2:5), which can be used after the concrete has set. Steel Grade A fireproof door direct deal Requirements for airtightness of fire doors: there are clear requirements for the size of the gap at each overlap of fire doors: for steel fire doors, the overlap between the leaf and the door frame shall not be less than 10mm, and the gap between the leaf and the door frame on both sides shall not be more than 4mm. The gap after the installation of the fire door cannot be too large, otherwise the airtightness of the fire door is difficult to guarantee, and it is difficult to reflect its role in restraining fire and smoke spread under fire conditions.