Henan fire door technical requirements Wooden fire door is a door with certain fire resistance performance, which is made of fire-resistant wood or fire-resistant wood products as door frame, door leaf framework, door leaf panel. If the door leaf is filled with materials, it is filled with fire insulation materials that are non-toxic and harmless to human body, and equipped with fire hardware accessories. supply Fire resistant rolling shutter door The overlapping size of door leaf and door frame shall not be less than 12mm; The fit clearance between the door leaf and the hinge side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The fit clearance between the door leaf and the locked side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The clearance between the door leaf and the upper frame shall not be greater than 3mm; The gap between two or more door leaves shall not be greater than 3mm; The movable clearance between the door leaf and the lower frame or ground shall not be greater than 9mm; The gap between the door leaf and the door frame binding surface: the gap between the door leaf and the binding surface of the door frame on the hinge side, the lock side and the upper frame shall not be greater than 3mm; The plane height difference between the door leaf and the door frame: On the opening surface of the fire door, the plane height difference between the door frame and the door leaf of Tianjin Telescopic Barcode Reader should not be greater than 1mm. Wooden fireproof door refers to the door frame, door leaf framework and door leaf panel made of wood or wood products, and the fire resistance limit of the door reaches the specified value. Some small deviations between wooden fireproof doors cannot be wrong. Maybe it is a small detail problem that may fail to meet the standard. Fire resistant rolling shutter door Price The materials used for Henan fire door are compared first. The fire door has a simple structure and is mainly composed of four parts: door closer, door panel materials (including 06 and 08), door frame materials, and fire panels. Grade A fireproof door is generally made of 08 material with good quality. Its normal service life is 5-8 years. The iron material of the door panel is thick. For the fireproof door with the same thickness, the weight of Grade A fireproof door is greater than that of Grade B.

The use and maintenance of henan fire rolling shutter door henan fire rolling shutter door is a very important fire protection facility for fire compartment and fire partition in public places. supply Fire resistant rolling shutter door It is also a fire protection product with comprehensive mechanical and electrical performance, so the installed fire shutter should always be kept in normal condition. During the use of Henan fire rolling shutter door, special equipment shall be used and kept by special personnel, and have certain basic knowledge of electricians and machinery. During the operation of fire rolling shutter door, the operator shall not leave the operation site without authorization, and shall pay close attention to the opening and closing conditions and implementation conditions. No one is allowed to stand or walk under the shutter when opening and closing. To prevent travel switch failure, roller shutter stuck, motor blocked and other accidents. The steel fire shutter of fire compartment and fire partition is not frequently used at ordinary times. In case of fire in the area, the shutter should be put into use effectively. The automatic control fire shutter with linkage control and central control center control must be carried out according to a set of control command procedures. Fire rolling shutter door.jpg The basic function of Henan fire rolling shutter door is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. This product is very good at preventing ultraviolet rays. The temperature is relatively high in summer, and one of these products can prevent ultraviolet rays. The ultraviolet radiation is destructive to human skin, so it seems very important. This product has helped me. This product still has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. Fire resistant rolling shutter door Price We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

What problems should be paid attention to during the installation of Henan fire door? Henan fire door manufacturers should know that the use performance of fire doors comes from the quality problems of the fire doors themselves on the one hand, and the installation of fire doors on the other hand. If the fire doors are not installed according to the relevant standards, then their fire performance may be affected in the use process. supply Fire resistant rolling shutter door Here are some precautions for installation. 1. When installing door frames and leaves, attention shall be paid to the opening direction of the door, which must be opened in the direction of evacuation. 2. Stealing work and materials is strictly prohibited. Some construction units speed up construction. There are serious problems of cutting work and materials when installing fire doors. Some do not install door closers or sequencers; Some fire doors should be equipped with 3 hinges, and they only have 2 or 1 hinge; Some fireproof door hinges with 4 screw holes are only installed with 2 screws, reducing the fixing strength; Some even install non fireproof hardware fittings and door locks; Some do not install fireproof sealing strips; Some fireproof doors are equipped with ordinary glass or fireproof glass that exceeds the specified area, etc. It is important to know that these jerry building will be reflected in the use of fireproof doors later. Fire resistant rolling shutter door Price Fire doors have special functions of fire prevention, smoke separation, fire spread suppression and evacuation protection, so they should have good airtightness. Therefore, attention should be paid to some details or sealing problems during installation.

Can the door of Henan Refuge Room be removed? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings, for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be equipped with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The door of the room should be Class B fireproof door, and the fire resistance integrity of the outer window should not be less than 1.00h. supply Fire resistant rolling shutter door The total net width of each door, emergency exit, evacuation walkway and evacuation staircase of the residential building shall be determined by calculation, and the net width of the door and emergency exit shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation outer door shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. The relevant requirements of the Code for Fire Protection Design of Henan Refuge Room Door Buildings stipulate that: 1. Evacuation in buildings with Class I and II fire resistance rating] or the linear distance from any point in the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 emergency exits to the nearest evacuation] or the emergency exit shall not be more than 30m. 2. When the evacuation door] cannot directly connect to the outdoor ground or the evacuation staircase, an evacuation corridor with a length of no more than 10m shall be used to connect to the nearest emergency exit. Fire resistant rolling shutter door Price When the place is equipped with automatic sprinkler system, the safe evacuation distance from any indoor point to the near emergency exit can be increased by 25%.

Maintenance and cultivation of Henan fire rolling shutter All fire rolling shutters should be checked and tested once a week. The test content includes: fire rolling shutter escape function test. supply Fire resistant rolling shutter door After the fire roller shutter is in the linkage state and drops to the bottom, press any manual button on both sides of the fire roller shutter, and the fire roller shutter shall be able to rise to the limit position (or drop to the bottom again after a delay). The lifting, lowering and stopping test of the manual buttons on both sides of the fire shutter. The fire rolling shutter shall be able to operate according to the instructions, and the operation shall be stable without blocking, not to mention uneven running speed of the shutter, stacking of the shutter or derailment. Test of manual emergency device. The manual zipper is used to lift the fire shutter, and the manual quick release device is used to lower the fire shutter. The fire shutter shall be able to run smoothly. Simulate the fire signal for linkage test. It is required that the fire shutter should be able to descend according to the normal procedure, and the contents and parts displayed in the fire control room should be consistent with the actual situation. Check whether the sealing of fire shutter is intact and damaged. The inspection above Henan fire rolling shutter door shall be carefully recorded, and the problems found shall be solved in a timely manner without leaving hidden dangers. Check whether the appearance of the fire shutter is intact and whether the curtain surface is damaged. Henan fire shutter door The door leaf of Henan fire shutter door cannot move: sensor failure is the major cause of the fire shutter door leaf cannot move. When such a situation occurs, be sure to check whether the sensor signal light is normal. If it is not the fault of the sensor, it may be that the wire connector is loose, the belt falls off, the controller is burned, the foreign matter is stuck, the voltage is abnormal, and so on. Pay attention to check and eliminate them one by one. Fire resistant rolling shutter door Price The door leaf of the fire rolling shutter jumps when opening and closing: the reason for this fault is very simple. If the track of the fire rolling shutter is jammed by foreign matters, it is necessary to check the tracks on both sides of the door leaf, remove the foreign matters, and the fault can be solved. The opening and closing speed of the fire shutter door leaf is too slow: customers often hear this situation. It may be that the speed adjustment of the national controller is too slow, or the belt is too loose, resulting in friction between the fire shutter door leaf and the guide rail. When handling, check these two parts. If the speed is too slow, adjust them faster. If the belt is too loose, tighten it in time.