
Maintenance methods and precautions of Henan fireproof door Maintenance methods and precautions of Henan fireproof door: 1. Door leaf and door frame shall be placed horizontally and stacked indoors with backing plates, and the frame and door leaf shall be stacked separately. 2. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 3. It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 4. Try to avoid outdoor sunshine for a long time to prevent the fire door from being heated. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. supply anti-theft door After splashing with water, wipe it with dry cloth to avoid local expansion. 6. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. 7. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. 8. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 9. Do not support the door for a long time without closing it, which will damage the door closer and make it lose its function. 10. Do not pull off the fireproof seal, or it will lose its function in case of fire. 11. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 12. When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. 13. The fire door closer must be replaced in case of oil leakage. anti-theft door direct deal Then, the Henan Fireproof Doors and Windows Editor summarized the above contents into the following points, and you must remember! Do not always open: it is prohibited to manually keep the normally closed fire doors set on the evacuation walkway, the front room of the smoke proof staircase or the shared front room open during the use process to become "normally open" fire doors. In case of a fire, such "normally open" fire doors can not prevent smoke and fire; Regular inspection: frequently check the integrity of the fire door, check whether the door closer and sequencer are in good use, whether the fire door can be closed automatically in order, and whether the screws on the hinge and hinge are loose. If damaged, immediately organize maintenance; Decoration: one-sided pursuit of decoration effect, canceling the fire door frame and setting only the door pocket made of ordinary wood, replacing the original frame of the door leaf with other materials, and adding decorative surface layer in a large range, thus damaging the fire retardant coating and failing to achieve fire retardant effect; Regular test: the normally open fire door shall be tested regularly to check whether its self closing control system, door closer, sequencer, release switch and other aspects are easy to use, whether it can effectively perform the self closing function in case of fire, and at the same time, it is necessary to resolutely prevent the random stacking of articles near the normally open fire door.

Analysis on the influence of fire resistance time of henan fire rolling shutter door on the coming of fire hazard in building fire protection design, ensuring safe evacuation of personnel is the primary premise of fire protection design, and the important standard of fire safety evacuation is time. supply anti-theft door China has made detailed regulations on the setting of evacuation width, evacuation distance, various fire-fighting facilities and other elements in various fire technical specifications. These are hard standards for fire design and review, but in fact, these requirements are not isolated from each other and created out of thin air. They all serve to ensure the safe evacuation of people, The setting requirements in the specification mostly come from the calculation of the fire safety evacuation time, so understanding the fire safety evacuation time is the basis and premise for the design and installation of fire rolling shutter doors. The so-called safe evacuation of Henan fire shutter door refers to the evacuation of people to a safe area before the fire develops to threaten the safety of people, that is, to make the safe evacuation time less than the time of danger, which is the benchmark of evacuation design, and all other design elements should serve this goal. The main factors that can cause danger to people in fire are high temperature, toxic smoke, building structure collapse and so on. The high temperature is mainly caused by thermal convection and radiation. When the air temperature reaches 100 ℃, ordinary people can only endure it for more than 10 minutes. When the temperature exceeds 200 ℃, people will die within 5 minutes. The harmful gases in the smoke mainly include carbon monoxide, carbon dioxide, formaldehyde, acetaldehyde, hydrogen cyanide, etc. The common carbon monoxide content in the air as long as 1%, people will lose consciousness after breathing several times, which will lead to death. At present, a large number of polyethylene, polystyrene and other building materials will produce toxic smoke after combustion. Smoke will not only cause poisoning, but also reduce the visibility of people in dense smoke due to the dimming effect of smoke. When the visibility is less than 0.5m, the moving speed of people is equivalent to the walking speed when they lose their vision. anti-theft door direct deal Henan fireproof rolling shutter door usually has a fire resistance limit much higher than the time of smoke spreading and flowing, but if flammable and combustible decoration materials are used in the evacuation passageway, it may also burn rapidly.

A brief talk on the problems encountered in the fire acceptance of Henan fire rolling shutter door 1. The curtain plate coating falls off and rusts, and the curtain plate has obvious pressure pits, concave convex, and penetrating holes. supply anti-theft door The rolling shutter is a complete fire protection product. If the shutter has problems, it will directly affect the fire resistance limit index of the rolling shutter. 2. The guide rail is deformed and the curtain board is stuck or falls unevenly. The fireproof rolling shutter door generally moves along the guide rail. If the guide rail is twisted or broken, the rolling shutter door will not be able to move to the specified position, which will not achieve the effect of fire separation. 3. On the roller shutter, the lower limit fails or the limit line is wrongly connected. anti-theft door direct deal This often happens on the fire roller shutter of the atrium. Because the fire roller shutter of the atrium is sometimes installed outside the walkway of the upper floor, there is no floor under the roller shutter to close it, and a large gap is leaked, so the fire separation of the upper and lower floors cannot be reached.

The installation of Henan fire rolling shutter door is prone to some problems. One problem is the strength of the transmission device of the fire rolling shutter door. The strength of the roller shutter shaft is also an important parameter of the roller shutter door. At present, there are many unqualified products with this strength, The structure of the roller shutter shaft that seriously affects the use of the fire shutter door mainly refers to the depth of the roller shutter shaft and the shaft heads at both ends plugged into the steel pipe and the depth of the structural shaft head plugged into the steel pipe should be about 110 of the shaft length, and there should be two flanges and enough welds. supply anti-theft door The second problem is the depth of the guide rail. If the depth of the guide rail is not enough and the structure and materials are improper, once encountering a fire, the door curtain is easy to detach from the guide rail and cannot play a role in fire prevention. anti-theft door direct deal The third problem is the pre rolling of the fire rolling shutter door. The fire rolling shutter door, especially the steel fire rolling shutter door, is relatively heavy, so a circle of pre rolling will be reserved on the reel to reduce the tension of the curtain weight on the screws. Prevent a curtain from cracking.