Analysis on the influence of fire resistance time of henan fire rolling shutter door on the coming of fire hazard in building fire protection design, ensuring safe evacuation of personnel is the primary premise of fire protection design, and the important standard of fire safety evacuation is time. high quality Class A fireproof window China has made detailed regulations on the setting of evacuation width, evacuation distance, various fire-fighting facilities and other elements in various fire technical specifications. These are hard standards for fire design and review, but in fact, these requirements are not isolated from each other and created out of thin air. They all serve to ensure the safe evacuation of people, The setting requirements in the specification mostly come from the calculation of the fire safety evacuation time, so understanding the fire safety evacuation time is the basis and premise for the design and installation of fire rolling shutter doors. The so-called safe evacuation of Henan fire shutter door refers to the evacuation of people to a safe area before the fire develops to threaten the safety of people, that is, to make the safe evacuation time less than the time of danger, which is the benchmark of evacuation design, and all other design elements should serve this goal. The main factors that can cause danger to people in fire are high temperature, toxic smoke, building structure collapse and so on. The high temperature is mainly caused by thermal convection and radiation. When the air temperature reaches 100 ℃, ordinary people can only endure it for more than 10 minutes. When the temperature exceeds 200 ℃, people will die within 5 minutes. The harmful gases in the smoke mainly include carbon monoxide, carbon dioxide, formaldehyde, acetaldehyde, hydrogen cyanide, etc. The common carbon monoxide content in the air as long as 1%, people will lose consciousness after breathing several times, which will lead to death. At present, a large number of polyethylene, polystyrene and other building materials will produce toxic smoke after combustion. Smoke will not only cause poisoning, but also reduce the visibility of people in dense smoke due to the dimming effect of smoke. When the visibility is less than 0.5m, the moving speed of people is equivalent to the walking speed when they lose their vision. Class A fireproof window Price Henan fireproof rolling shutter door usually has a fire resistance limit much higher than the time of smoke spreading and flowing, but if flammable and combustible decoration materials are used in the evacuation passageway, it may also burn rapidly.

The type, type, specification, size, opening direction, device position and anti-corrosion solution of Henan fire rolling shutter door shall meet the design requirements. high quality Class A fireproof window The accessories of the roller shutter door are complete, the position is accurate, the device is stable, and the function should meet the use requirements and various performance requirements of Luoyang roller shutter door. The rolling shutter must be firmly installed, and the number, position, embedding method and connection method with the frame of the embedded parts must meet the design requirements. The appearance of the rolling shutter door shall be clean without scratches and bruises. Eight advantages of Henan fireproof rolling shutter door: energy saving: two key technologies realize energy saving. First of all, the door opening design and double door interlock greatly shorten the door opening cycle. For clean rooms, the shortening of the door opening cycle can reduce the indoor air loss and improve the insulation capacity. In addition, there are double rows of encrypted sealing brushes inside the column of the fast door, and the pvc base card design makes installation and replacement convenient. Cost saving: The fast door is equipped with a LCD display, which will prompt when the door fails to operate, and the code or Chinese display will be displayed. This can avoid costly downtime and time-consuming technical maintenance, which greatly saves costs. Complete types: fast doors include explosion-proof fast doors, wind resistant fast doors, zippered fast doors (also called anti-collision automatic reset fast doors). Rich functions: Henan explosion-proof rolling shutter door can be linked with the air shower room, goods elevator, mechanical arm, assembly line, etc. High efficiency: according to the actual situation and requirements of customers on the site, provide a variety of control switches to improve the efficiency of daily operation. There are radar induction door opening, rope pulling door opening, geomagnetic induction door opening, remote control door opening, card swiping door access control door opening and other door opening methods. Safety: The bottom of Henan fast rolling shutter door is air tight and soft, and the door curtain is soft. There are safety photoelectric devices on both sides of the track. When there are people or obstacles under the door body, the door body will not fall, to ensure that people will not be touched by the door body. Class A fireproof window Price After sales guarantee: the control system of the fast door can timely identify the fault of Henan fast rolling shutter door, and then solve the problem in time. Yuou Door&Window Technology has a special after-sales maintenance department, which can respond within 12 hours if there is a fault.

Henan fire door is an important part of fire fighting equipment. Fire door is an important part of fire fighting equipment and an important part of social fire prevention. Therefore, the quality and use of fire door is the key to the success of fire prevention. high quality Class A fireproof window The fire resistance limit of Class C fireproof door is 0.6h) 1. The inspection door on the wall of equipment tube well, ventilation duct and garbage duct shall be Class C fireproof door. 2. The front door of the garbage way shall be Class C fireproof door. 3. When the cable shaft and pipe shaft are set in the front room of the smoke proof staircase and the shared front room, the inspection door on the shaft wall shall be Class C fireproof door. 4. The door connecting the substation and distribution substation should be Class C fireproof door. The door directly leading to the outdoor of the substation shall be Class C fireproof door. 5. The cable well and pipe well shall be separated from each other every 2~3 floors by incombustible materials equivalent to the fire resistance limit of the floor. The inspection door on the shaft wall shall be Class C fire door. 6. The garbage hopper shall be made of incombustible and corrosion-resistant materials and can be closed and sealed by itself; Garbage hoppers of high-rise buildings and super high-rise buildings shall be located in the front room of the garbage chute, which shall be equipped with Class C fireproof doors. 7. The telecommunication room shall adopt outward opening Class C fireproof door with a width of more than 0.7m. 8. The oxygen busbar room with the oxygen delivery capacity not exceeding 60m3/h can be set in the user's workshop with the fire resistance rating not lower than Grade III and close to the external wall. The wall with the height of 2.5m and the fire resistance rating not lower than 1.5h and the Grade C fire door should be used to separate it from other parts of the workshop. 9. The partition wall of the collection warehouse and exhibition room shall be non combustible. The compartments in the fire compartment shall be separated by partition walls with a fire resistance rating of not less than 3h and Class B fire doors. The enclosure structure of closed shaft shall be non combustible and Class C fireproof door. 10. The fire resistance limit of partition walls between production rooms with explosion risk shall not be less than 1.5h. Class A fireproof window Price The door is Class C fireproof door. 11. When the oxygen generation station building or liquid oxygen gasification station building and oxygen filling station building are arranged in the same building, the noncombustible partition wall with a fire resistance rating of not less than 1.5h and Class C fire door shall be used, and they shall be connected through the walkway. 12. The doors on the partition walls between the oxygen compressor room and the bottle filling room, as well as the purification room, the oxygen storage bag room, the oxygen storage tank room, the liquid oxygen storage tank room and other rooms shall be Class C fireproof doors.

Relevant requirements for fire protection of the door of Henan Refuge Room What kind of products are qualified when the door of Henan Refuge Room passes the fire protection? Here are some examples: 1. Filling materials: the filling materials must meet the requirements of combustion performance A1 specified in GB8624-2006. At the same time, it meets the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 2. Material thickness: door leaf material shall be no less than 0.8mm, door panel material shall be no less than 0.8mm, door frame plate shall be no less than 1.2mm, hinge plate shall be no less than 3.0mm, reinforcement without screw holes shall be no less than 1.2mm, and reinforcement with screw holes shall be no less than 3.00mm. high quality Class A fireproof window The door of Henan refuge room 3. The adhesive shall meet the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 4. Dimensional deviation: the height of the door leaf shall not exceed 2mm, the width of the door leaf shall not exceed 2mm, the thickness of the door leaf shall be between - 1mm and+2mm, the height of the clipping opening in the door frame shall not exceed 3mm, the width of the clipping opening in the door frame shall not exceed 2mm, and the width of the side wall of the door frame shall not exceed 2mm. 5. Geometric tolerance: the length difference between the two diagonals of the door leaf shall be less than or equal to 3mm, The distortion of the door leaf shall be less than or equal to 5mm, the curvature of the door leaf in the width direction shall be less than 2%, the curvature of the door leaf in the height direction shall be less than 2%, and the length difference between the two diagonals of the inner cutting opening shall be less than or equal to 3mm. 6. Fit tolerance: the overlap size between Manshan and the door frame is less than or equal to 12mm, the fit clearance between the door leaf and the door frame at the hinge side shall not be greater than the size tolerance specified in the design drawing, and the fit clearance between the door leaf and the door frame at the lock side shall not be greater than the size tolerance specified in the design drawing. Class A fireproof window Price The clearance between the door leaf and the upper frame shall be less than or equal to 3mm, the clearance between the double leaf and multi leaf door leaves shall be less than or equal to 3mm, the clearance between the door leaf and the lower frame or the ground shall be less than or equal to 9mm, the clearance between the binding surface of the door leaf and the side of the door frame with hinges shall be less than or equal to 3mm, the clearance between the binding surface of the door leaf and the side of the door frame with locks shall be less than or equal to 3mm, and the clearance between the binding surface of the door leaf and the upper frame of the door frame shall be less than or equal to 3mm, The plane height difference between the door frame and the door leaf is less than or equal to 1mm.

Henan fire door refers to the door that can meet the requirements of fire resistance stability, integrity and heat insulation within a certain period of time. high quality Class A fireproof window It is a fire compartment with certain fire resistance, which is located in fire compartment, evacuation staircase, vertical shaft, etc. In addition to the function of ordinary doors, fire doors can also prevent the spread of fire and smoke, which can prevent the spread of fire within a certain period of time and ensure the evacuation of people. Henan fire doors are certified by the Ministry of Economy of the Ministry of Fire Protection of the People's Republic of China. According to the new version of the standard for fire doors GB_12955-2008 implemented on January 1, 2009, those who pass the fire resistance test of fire doors and have obtained the registration certificate and authorized logo issued by the Bureau of Standards and Inspection of the Ministry of Economy are called fire doors. Class A fireproof window Price The fire door defined in the American NFPA and IBC codes is "any combination of fire door leaves, door frames, hardware and other accessories that can jointly provide a certain degree of fire protection at the opening."