Luoyang professional fireproof roller shutter manufacturer direct sales

Your current location: home page > Hot information

Luoyang professional fireproof roller shutter manufacturer direct sales

2022-07-18
 Luoyang professional fireproof roller shutter manufacturer direct sales

The role of Henan fire doors in fire protection We often see on the ground of some large or local places that no one is allowed to stand under the fire facilities or shelves are placed. major Fire resistant roller shutter Then, the primary use of assembling fire doors is that if a fire occurs in a certain place, the rolling shutter door can stop the extension of the fire when it is put down. Usually, the fire doors in such large buildings have automatic central control systems. Once a fire occurs, you can automatically implement a series of behaviors, and the fire doors will automatically lower the fire. The following is the employment process of the automatic control system of the fire door. When a fire occurs, the smoke sensor installed on the roof receives the flag of the smoke and alarms to the central control system. After identification, the control system of the fire center connects the power supply of the fire door in the fire alarm location area, so that the fire shutter in the fire area will fall to the ground at the required rate. When the roller shutter passes to a position about 1.5 meters above the ground, stop the activity, so as to facilitate the evacuation and evacuation of employees on site. After the associated employees withdraw together, the fire door will continue to go down until it is closed. The descending rate of the fire door and the time of stay during the period can be adjusted according to the number of employees. Fire resistant roller shutter direct deal It is not only such places that are equipped with fire doors, but also in some staircases, corridors and other places. Since fire is rarely generated and some fire prevention settings are easy to use, the conditions must be inspected regularly by dedicated staff.

 Luoyang professional fireproof roller shutter manufacturer direct sales

Henan fire door development prospects 1. The fire door industry is also an emerging industry, with huge market capacity and market potential. 2. Due to the high qualification threshold of fire doors, there are not many manufacturers that can really enter the fire door industry, but also Grade C fire doors Grade C fire doors Henan fire doors. According to incomplete statistics, there are more than 1000 fire door enterprises. major Fire resistant roller shutter This does not include those family workshop type processing units. The products produced by these processing units are of different grades, with prices ranging from hundreds to thousands of yuan. 3. The market pattern in the industry has not been formed yet. There are few large enterprises and brands, and there is no leading brand. The research, development and production of fire door products have played a positive role in ensuring the safety of people's lives and property. China's fire door market started late, but developed rapidly. In recent years, some European and American enterprises have actively participated in the competition in the Chinese fire door market, especially European enterprises, which are trying to make European fire doors occupy more of the Chinese market. Fire resistant roller shutter direct deal In the face of competitors, we must face up to the current situation. On the one hand, we should learn from our competitors modestly, and on the other hand, we should strive to enhance our own strength. Fire door manufacturers in China are facing a huge challenge. Who can seize the opportunity in this challenge will become a winner in the market.

 Luoyang professional fireproof roller shutter manufacturer direct sales

What is the difference between the normally open and normally closed fire doors of Henan fire doors? The differences between the normally open and normally closed fire doors are as follows: 1. Different meanings. The normally open fire doors are usually open, and they are automatically closed by the control system only in case of fire. It is generally used in the passage or corridor of public places. major Fire resistant roller shutter Normally closed fire doors are closed under normal conditions and in case of fire, and need to be pushed open when someone walks around, so as to prevent smoke and fire and prevent the spread of fire. 2. The price is different, and the price of the normally open fire door is higher, and the system is strong. The price of normally closed fire doors is relatively low. Henan fireproof doors and windows 3. The composition is different. The normally open fireproof door consists of door leaf, door frame, door closer, sealing strip, release switch and other parts. The normally closed fireproof door is equipped with sequencer in addition to the above parts. 4. The control mode is different. The normally open fire door is controlled by the fire door release switch. The normally closed fire door does not need to be set with electric automatic control. It is mainly closed by the door closer and sequencer, that is, mechanical. Precautions for Henan fire door fire door 1. The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2. The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3. No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. Henan fireproof doors and windows 4. When installing the fireproof door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted, and then it can be connected and anchored. 5. The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. Fire resistant roller shutter direct deal Henan fireproof doors and windows 6. Door closers must be installed on fireproof doors, and sequencers must be installed on opposite doors. 7. The handle, fire lock and other hardware accessories on the fire door must be complete. 8. It is required that the clearance from the ground plane shall not be greater than 5mm.

 Luoyang professional fireproof roller shutter manufacturer direct sales

The operation method of Henan fire doors is recognized by the laboratory of the Ministry of Economy of the Ministry of Fire Protection. According to the new version of the standard for fire doors GB_12955-2008 implemented on January 1, 2009, those who pass the fire resistance test method of fire doors and obtain the registration certificate and authorization mark issued by the Bureau of Standards and Inspection of the Ministry of Economy are called fire doors. major Fire resistant roller shutter The fire door defined in the American NFPA and IBC codes is "the combination of any fire door leaf, door frame, hardware and other accessories that can jointly provide a certain degree of fire protection at the opening." Operation method Henan fire door widely carries out publicity and education on the use, maintenance and management of fire prevention facilities within the jurisdiction of the fire department in charge, Efforts should be made to improve people's awareness of fire protection and self-protection; Extensive publicity, education and training on fire protection and umbrella protection knowledge shall be carried out for units installed with fire door maintenance, so as to make every employee understand the basic knowledge of the use, maintenance and management of fire door maintenance, and consciously participate in the maintenance and management of the Gate of Life, so as to keep them in a state of combat readiness at all times; The fire door maintenance purpose, function and good use status and basic requirements for use shall be posted on the fire door maintenance, and the words "normally closed fire door maintenance, please close at any time" shall be written on the conspicuous position of the normally closed fire door maintenance, so that customers and the masses can understand the basic knowledge of fire door maintenance. Fire resistant roller shutter direct deal Carry out publicity activities to protect fire-fighting facilities and equipment, and mobilize everyone to participate in the protection of fire-fighting facilities such as fire door maintenance.

 Luoyang professional fireproof roller shutter manufacturer direct sales

Henan fireproof door installation method The fireproof door is divided into steel fireproof door and wooden fireproof door according to the material. There are some differences in the installation method of the two fireproof doors. major Fire resistant roller shutter The fire rating is slightly different. You must pay attention to the details when installing. First of all, when installing the wooden fireproof door, the size of the door frame should be 20mm smaller than the opening, and the lower foot of the door frame should be buried 20mm below the ground. The door frame should be firmly fixed with the wall, and perpendicular to the corner. The vertical frame and bracing frame shall be straight and at the same angle to avoid planing and sawing. There shall be no less than 3 fixed points on both sides of the door frame, and the spacing shall not be greater than 800mm. Secondly, during the installation of the steel fire door, considering the bending deformation of the door frame, it is necessary to support the door frame with wooden braces in the width direction of the door frame. The lower foot of the door frame is buried 20 mm below the ground, and then the door frame is welded with the embedded parts on the wall. Then make a hole in the wall at the upper corner of the door frame, and pour concrete of cement, sand and expanded perlite (1:2:5), which can be used after the concrete has set. Fire resistant roller shutter direct deal Requirements for airtightness of fire doors: there are clear requirements for the size of the gap at each overlap of fire doors: for steel fire doors, the overlap between the leaf and the door frame shall not be less than 10mm, and the gap between the leaf and the door frame on both sides shall not be more than 4mm. The gap after the installation of the fire door cannot be too large, otherwise the airtightness of the fire door is difficult to guarantee, and it is difficult to reflect its role in restraining fire and smoke spread under fire conditions.