What are the requirements for the width of the door of Henan Refuge Room? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings: for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be set with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The [] of the room should adopt the Z-grade fire door, and the fire resistance integrity of the outer window should not be less than 1.00h. major anti-theft door The total net width of the door, emergency exit, evacuation walkway and evacuation staircase of the residential building with the door of Henan refuge room shall be determined by calculation, and the net width of the door, emergency exit and evacuation staircase shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. anti-theft door Price The relevant requirements of the Code for Fire Protection Design of Buildings stipulate that: 1. For the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 evacuation [] or emergency exits in buildings of Class I and II fire resistance rating, the straight-line distance from any indoor point to the evacuation door] or emergency exit shall not be more than 30 m.

Maintenance methods and precautions of Henan fireproof door Maintenance methods and precautions of Henan fireproof door: 1. Door leaf and door frame shall be placed horizontally and stacked indoors with backing plates, and the frame and door leaf shall be stacked separately. 2. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 3. It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 4. Try to avoid outdoor sunshine for a long time to prevent the fire door from being heated. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. major anti-theft door After splashing with water, wipe it with dry cloth to avoid local expansion. 6. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. 7. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. 8. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 9. Do not support the door for a long time without closing it, which will damage the door closer and make it lose its function. 10. Do not pull off the fireproof seal, or it will lose its function in case of fire. 11. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 12. When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. 13. The fire door closer must be replaced in case of oil leakage. anti-theft door Price Then, the Henan Fireproof Doors and Windows Editor summarized the above contents into the following points, and you must remember! Do not always open: it is prohibited to manually keep the normally closed fire doors set on the evacuation walkway, the front room of the smoke proof staircase or the shared front room open during the use process to become "normally open" fire doors. In case of a fire, such "normally open" fire doors can not prevent smoke and fire; Regular inspection: frequently check the integrity of the fire door, check whether the door closer and sequencer are in good use, whether the fire door can be closed automatically in order, and whether the screws on the hinge and hinge are loose. If damaged, immediately organize maintenance; Decoration: one-sided pursuit of decoration effect, canceling the fire door frame and setting only the door pocket made of ordinary wood, replacing the original frame of the door leaf with other materials, and adding decorative surface layer in a large range, thus damaging the fire retardant coating and failing to achieve fire retardant effect; Regular test: the normally open fire door shall be tested regularly to check whether its self closing control system, door closer, sequencer, release switch and other aspects are easy to use, whether it can effectively perform the self closing function in case of fire, and at the same time, it is necessary to resolutely prevent the random stacking of articles near the normally open fire door.

What is the difference between the normally open and normally closed fire doors of Henan fire doors? The differences between the normally open and normally closed fire doors are as follows: 1. Different meanings. The normally open fire doors are usually open, and they are automatically closed by the control system only in case of fire. It is generally used in the passage or corridor of public places. major anti-theft door Normally closed fire doors are closed under normal conditions and in case of fire, and need to be pushed open when someone walks around, so as to prevent smoke and fire and prevent the spread of fire. 2. The price is different, and the price of the normally open fire door is higher, and the system is strong. The price of normally closed fire doors is relatively low. Henan fireproof doors and windows 3. The composition is different. The normally open fireproof door consists of door leaf, door frame, door closer, sealing strip, release switch and other parts. The normally closed fireproof door is equipped with sequencer in addition to the above parts. 4. The control mode is different. The normally open fire door is controlled by the fire door release switch. The normally closed fire door does not need to be set with electric automatic control. It is mainly closed by the door closer and sequencer, that is, mechanical. Precautions for Henan fire door fire door 1. The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2. The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3. No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. Henan fireproof doors and windows 4. When installing the fireproof door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted, and then it can be connected and anchored. 5. The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. anti-theft door Price Henan fireproof doors and windows 6. Door closers must be installed on fireproof doors, and sequencers must be installed on opposite doors. 7. The handle, fire lock and other hardware accessories on the fire door must be complete. 8. It is required that the clearance from the ground plane shall not be greater than 5mm.

The advantages and problems in the development of fire doors in Henan Province Fire doors are more popular in recent years, so how much do you know about the maintenance, advantages and development of fire doors? The following section will provide you with a comprehensive knowledge of fire doors, so that you can better understand fire doors. major anti-theft door Fireproof door is a kind of movable fireproof partition. In addition to the function of ordinary door, it, together with the frame, can meet the requirements of fire resistance stability and integrity within a certain period of time. It has special functions of fire prevention, smoke separation and high temperature blocking. In case of fire, it should have self closing and signal feedback functions. (1) Advantages of fire doors In case of fire, Henan fire doors and windows can be automatically closed through the linkage control system when they are in the open shoulder state, effectively ensuring the reliable closing of fire door maintenance in the fire, so as to achieve its due role in smoke separation and fire resistance. There is no big difference between the maintenance of fire doors and the maintenance of normally closed fire doors in terms of production and basic configuration, but the door closers for the maintenance of normally closed fire doors are replaced with automatic fire release devices that are linked with the automatic fire alarm. At the same time, they can be installed with the control box produced by the manufacturer. Linkage is achieved by installing smoke detectors and smoke detectors on the left and right sides of the maintenance of fire doors, When the smoke detector detects the smoke signal and sends it to the host computer of the automatic fire alarm linkage control system, the linkage control system transmits 24v power to the fire door maintenance releaser to automatically close the fire door for maintenance. The closing or opening status of the fire door maintenance has signals fed back to the alarm host computer or control box. anti-theft door Price The automatic release device for fire door maintenance developed by Dong Shicong of Chengdu Huili University Research Institute can open the fire door maintenance for 0-180 degrees freely and close it smoothly, completely changing the disadvantage of inconvenient use of the normally closed fire door maintenance closer due to its large opening angle of 90 degrees, and once the fire door is closed for maintenance, the release device will not be reset, It has become a movable fire door maintenance that automatically opens, closes, opens and closes, overcoming the contradiction that normally closed fire doors must be manually closed or cannot be closed after being pushed to a certain limit (greater than 90 degrees) for maintenance; The lesson of blood proves that people who escape from a fire simply cannot close the opened fire door for maintenance due to panic and eagerness to escape.

Whether Henan fireproof door should be made of wood or steel? I think that many people's understanding of wooden fireproof door is still in the process of questioning whether wooden fireproof door can be safe against fire. There is no need to talk about whether steel fireproof door or wooden fireproof door is better. Usually people subconsciously think that steel fireproof door is better than wooden fireproof door. major anti-theft door According to the Code for Construction Quality Acceptance of Decoration Engineering? GB50210-2001? As far as wood fire doors are concerned, they belong to special doors. Therefore, wood fire doors can not only provide fire safety, but also are widely used in various industrial buildings and some public buildings because of their elegant appearance design, convenient installation and good decorative arts. But it is also beautiful and generous. In the final analysis, what about the wooden fire door with fire safety characteristics? Which is better, steel fire door or wood fire door? Let's have a look at their advantages and differences: wooden fireproof doors refer to those doors whose fire resistance rating exceeds the requirements of GB50045-95? Code for Fire Protection Design of High rise Residential Industrial Buildings with wood or wood handicrafts as door frames, door frame framework drawings, door frame control panels. anti-theft door Price Wooden fireproof doors are divided into full panel and half glass series products, as well as specifications and models of single and double leaves.