The role of Henan fire doors in fire protection We often see on the ground of some large or local places that no one is allowed to stand under the fire facilities or shelves are placed. major Class A fireproof window Then, the primary use of assembling fire doors is that if a fire occurs in a certain place, the rolling shutter door can stop the extension of the fire when it is put down. Usually, the fire doors in such large buildings have automatic central control systems. Once a fire occurs, you can automatically implement a series of behaviors, and the fire doors will automatically lower the fire. The following is the employment process of the automatic control system of the fire door. When a fire occurs, the smoke sensor installed on the roof receives the flag of the smoke and alarms to the central control system. After identification, the control system of the fire center connects the power supply of the fire door in the fire alarm location area, so that the fire shutter in the fire area will fall to the ground at the required rate. When the roller shutter passes to a position about 1.5 meters above the ground, stop the activity, so as to facilitate the evacuation and evacuation of employees on site. After the associated employees withdraw together, the fire door will continue to go down until it is closed. The descending rate of the fire door and the time of stay during the period can be adjusted according to the number of employees. Class A fireproof window Manufacturer It is not only such places that are equipped with fire doors, but also in some staircases, corridors and other places. Since fire is rarely generated and some fire prevention settings are easy to use, the conditions must be inspected regularly by dedicated staff.

Placement requirements, maintenance methods and precautions of Henan fire door at ordinary times Maintenance methods and precautions of fire door at ordinary times. major Class A fireproof window When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 2. Do not pull off the fireproof seal, or it will lose its function in case of fire. Henan fireproof doors and windows cannot be left open for a long time, which will damage the door closer and make it lose its function. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 3. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 4. Henan fireproof doors and windows shall be protected from outdoor sunshine for a long time to prevent the fireproof door from being heated. Class A fireproof window Manufacturer It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. After splashing with water, wipe it with dry cloth to avoid local expansion. The fire door closer must be replaced in case of oil leakage.

Why is Henan fire rolling shutter an indispensable facility? Why is fire rolling shutter an indispensable facility. major Class A fireproof window The types of fire rolling shutter doors in Henan mainly include composite steel fire rolling shutter (fire and smoke prevention), inorganic super grade fire rolling shutter (double track double shutter), steel composite water spray steam fog fire rolling shutter, steel composite lateral fire rolling shutter, steel composite horizontal fire rolling shutter, inorganic super grade folding fire rolling shutter and fire rolling shutter with various doors. The fireproof rolling shutter door, as well as the firewall, functions as a horizontal fireproof partition. It is composed of 13 parts, such as shutter, base plate, guide rail, support, reel, box, control box, door rolling machine, limiter, door header, manual quick release switch device, button switch and safety device, and is generally installed at the position that is not convenient for firewall separation. For example, open elevator halls, escalators, wide business halls of department stores, exhibition halls of exhibition buildings, and parts of buildings with large openings that cannot use fireproof doors and windows. Fire resisting rolling shutter door has been widely used in building engineering to make fire separation. Class A fireproof window Manufacturer Henan fireproof rolling shutter door is an indispensable fire prevention facility in modern high-rise buildings. In addition to the function of ordinary door, the fireproof door has the special functions of fire prevention, smoke separation, suppression of fire spread, and protection of personnel evacuation. It is widely used in high-rise buildings, large shopping malls and other crowded places.

Can the door of Henan Refuge Room be removed? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings, for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be equipped with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The door of the room should be Class B fireproof door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Class A fireproof window The total net width of each door, emergency exit, evacuation walkway and evacuation staircase of the residential building shall be determined by calculation, and the net width of the door and emergency exit shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation outer door shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. The relevant requirements of the Code for Fire Protection Design of Henan Refuge Room Door Buildings stipulate that: 1. Evacuation in buildings with Class I and II fire resistance rating] or the linear distance from any point in the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 emergency exits to the nearest evacuation] or the emergency exit shall not be more than 30m. 2. When the evacuation door] cannot directly connect to the outdoor ground or the evacuation staircase, an evacuation corridor with a length of no more than 10m shall be used to connect to the nearest emergency exit. Class A fireproof window Manufacturer When the place is equipped with automatic sprinkler system, the safe evacuation distance from any indoor point to the near emergency exit can be increased by 25%.