Relevant requirements for fire protection of the door of Henan Refuge Room What kind of products are qualified when the door of Henan Refuge Room passes the fire protection? Here are some examples: 1. Filling materials: the filling materials must meet the requirements of combustion performance A1 specified in GB8624-2006. At the same time, it meets the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 2. Material thickness: door leaf material shall be no less than 0.8mm, door panel material shall be no less than 0.8mm, door frame plate shall be no less than 1.2mm, hinge plate shall be no less than 3.0mm, reinforcement without screw holes shall be no less than 1.2mm, and reinforcement with screw holes shall be no less than 3.00mm. supply Refuge bay door The door of Henan refuge room 3. The adhesive shall meet the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 4. Dimensional deviation: the height of the door leaf shall not exceed 2mm, the width of the door leaf shall not exceed 2mm, the thickness of the door leaf shall be between - 1mm and+2mm, the height of the clipping opening in the door frame shall not exceed 3mm, the width of the clipping opening in the door frame shall not exceed 2mm, and the width of the side wall of the door frame shall not exceed 2mm. 5. Geometric tolerance: the length difference between the two diagonals of the door leaf shall be less than or equal to 3mm, The distortion of the door leaf shall be less than or equal to 5mm, the curvature of the door leaf in the width direction shall be less than 2%, the curvature of the door leaf in the height direction shall be less than 2%, and the length difference between the two diagonals of the inner cutting opening shall be less than or equal to 3mm. 6. Fit tolerance: the overlap size between Manshan and the door frame is less than or equal to 12mm, the fit clearance between the door leaf and the door frame at the hinge side shall not be greater than the size tolerance specified in the design drawing, and the fit clearance between the door leaf and the door frame at the lock side shall not be greater than the size tolerance specified in the design drawing. Refuge bay door direct deal The clearance between the door leaf and the upper frame shall be less than or equal to 3mm, the clearance between the double leaf and multi leaf door leaves shall be less than or equal to 3mm, the clearance between the door leaf and the lower frame or the ground shall be less than or equal to 9mm, the clearance between the binding surface of the door leaf and the side of the door frame with hinges shall be less than or equal to 3mm, the clearance between the binding surface of the door leaf and the side of the door frame with locks shall be less than or equal to 3mm, and the clearance between the binding surface of the door leaf and the upper frame of the door frame shall be less than or equal to 3mm, The plane height difference between the door frame and the door leaf is less than or equal to 1mm.

The advantages and problems in the development of fire doors in Henan Province Fire doors are more popular in recent years, so how much do you know about the maintenance, advantages and development of fire doors? The following section will provide you with a comprehensive knowledge of fire doors, so that you can better understand fire doors. supply Refuge bay door Fireproof door is a kind of movable fireproof partition. In addition to the function of ordinary door, it, together with the frame, can meet the requirements of fire resistance stability and integrity within a certain period of time. It has special functions of fire prevention, smoke separation and high temperature blocking. In case of fire, it should have self closing and signal feedback functions. (1) Advantages of fire doors In case of fire, Henan fire doors and windows can be automatically closed through the linkage control system when they are in the open shoulder state, effectively ensuring the reliable closing of fire door maintenance in the fire, so as to achieve its due role in smoke separation and fire resistance. There is no big difference between the maintenance of fire doors and the maintenance of normally closed fire doors in terms of production and basic configuration, but the door closers for the maintenance of normally closed fire doors are replaced with automatic fire release devices that are linked with the automatic fire alarm. At the same time, they can be installed with the control box produced by the manufacturer. Linkage is achieved by installing smoke detectors and smoke detectors on the left and right sides of the maintenance of fire doors, When the smoke detector detects the smoke signal and sends it to the host computer of the automatic fire alarm linkage control system, the linkage control system transmits 24v power to the fire door maintenance releaser to automatically close the fire door for maintenance. The closing or opening status of the fire door maintenance has signals fed back to the alarm host computer or control box. Refuge bay door direct deal The automatic release device for fire door maintenance developed by Dong Shicong of Chengdu Huili University Research Institute can open the fire door maintenance for 0-180 degrees freely and close it smoothly, completely changing the disadvantage of inconvenient use of the normally closed fire door maintenance closer due to its large opening angle of 90 degrees, and once the fire door is closed for maintenance, the release device will not be reset, It has become a movable fire door maintenance that automatically opens, closes, opens and closes, overcoming the contradiction that normally closed fire doors must be manually closed or cannot be closed after being pushed to a certain limit (greater than 90 degrees) for maintenance; The lesson of blood proves that people who escape from a fire simply cannot close the opened fire door for maintenance due to panic and eagerness to escape.

How to choose Henan fire door with good quality? Only the brand quality is excellent, can the fire door material reach a high strength and durable scale, or reach a high strength and airtight condition at the same time of fire prevention characteristics, or reach a difficult deformation quality under tropical burns, so as to eliminate the need for fire prevention. supply Refuge bay door In terms of material selection, it is also advisable to adopt wood and steel materials, and fire door body made of pure materials. The price of different materials is different, and it is possible to reach the standard with both fire prevention talents. Therefore, only manufacturers with strong brand advantages can reach a comfortable level in terms of quality conditions of fire doors, and may adopt high-quality and inexpensive fire doors. Fire doors are divided into wooden fire doors and steel fire doors in shopping malls. Some consumers have a misunderstanding that the fire resistance effect of wooden fire doors will be poor rather than steel. It is necessary to change this poor idea as soon as possible. Only wooden fire doors can pass good fire resistance treatment. Refuge bay door direct deal Its flame retardant effect will be no less than that of steel fire doors. The appearance of wooden fire doors is more elegant than that of steel doors. The assembly is convenient, not to mention the existing flame retardant effect and the elegant use of decorations.

The application of fire doors in Henan Province Fire doors are often required to be used in our lives. As everyone's life rhythm continues to accelerate, we do not pay attention to some minor abnormalities, which causes fires from time to time. supply Refuge bay door At the same time, there are many peers who are not familiar with its use and precautions. Literally, it is a kind of fire prevention device. Usually, it is installed in our kitchen or in the place where gas is installed. Because this kind of place is compared with the situation of simple fire, once any fire accident occurs, it may help everyone quickly get rid of the danger. When using this fire protection device, everyone must have the necessary knowledge of some precautions for its use, so that everyone can quickly control it. During the use, it is suggested that everyone should get to know the relevant information on the official website, or directly look at the use instructions of the settings. Such information is extremely important for users. It may help everyone not to list the signs of being at sixes and sevens during other unexpected periods. If everyone does not control the precautions for such use, it may not play the role of fire protection during dangerous periods. Refuge bay door direct deal Fire door is common in our life, and it is also one of the necessary settings. Without it, everyone's life is forced during the period. Therefore, it is very helpful for everyone to control some information about it or pay attention to its use! Everyone may as well use some other methods to get to know it.