上海龙凤shlf1314足浴

Hello! Welcome to the website of Henan Rui'andun Door Industry Co., Ltd!

 Henan fireproof door

contact us

Tel.: 0371-85127888

Fax: 0371-62495556

Mobile: 17788121396

Email: [email protected]

website: www.00151.cn

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City

Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

Your current location: home page > Hot information

Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

2022-10-07
 Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

Control Procedure for Internal Quality Management System of Henan Refuge Room Door Manufacturer 1. Purpose To conduct regular internal quality audits to verify the quality activities and related results. Stone composite procedure documents: CCCF-HZFH-02 (A/O) Rules for the Implementation of Compulsory Product Certification, Fire Protection Products, Fire Resistant Components of Buildings and other quality documents, and take corrective measures in a timely manner, So as to make the quality management system operate effectively and ensure that the product consistency meets the requirements of relevant approval rules. 2. The scope is applicable to the audit of our internal quality management system. 3. Responsibilities: The quality director shall lead the internal quality audit work, and the audit team leader shall organize the internal quality audit work under the centralized management of the office, with the cooperation of each department. Henan Refuge Room 4. Procedure (1) Audit frequency The internal quality management system of each department shall be audited at least once a year according to the following procedures. major Steel fire resistance rolling shutter door In case of major quality accident or other special reasons, the quality director shall decide to conduct targeted additional audit. (2) The Audit Planning Office shall propose the "Annual Internal Quality Management System Audit Plan" every year according to the actual situation and importance of audit activities, which shall be approved and implemented by the quality director. (3) Auditors The auditors shall have the qualification of internal auditors and have no direct responsibility for the audited activities, and shall be appointed by the General Manager. For the temporary additional audit, the quality director shall specify the audit team leader and auditors. (4) Before each audit, the office shall prepare the "audit schedule plan", which shall be approved by the person in charge of quality. The audit team leader reviews the documents and assigns tasks to the auditors, who prepare the audit checklist. (5) Audited department and audit schedule; Purpose, scope and basis of audit; Audit content and specific time arrangement; Division of auditors, etc. Steel fire resistance rolling shutter door direct deal The audit schedule shall be sent by the audit team leader to the audited department one week in advance. After receiving the audit schedule, the audited department can notify the audit team leader in advance if there is any objection. After negotiation, it can make appropriate adjustments.

 Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

The type, type, specification, size, opening direction, device position and anti-corrosion solution of Henan fire rolling shutter door shall meet the design requirements. major Steel fire resistance rolling shutter door The accessories of the roller shutter door are complete, the position is accurate, the device is stable, and the function should meet the use requirements and various performance requirements of Luoyang roller shutter door. The rolling shutter must be firmly installed, and the number, position, embedding method and connection method with the frame of the embedded parts must meet the design requirements. The appearance of the rolling shutter door shall be clean without scratches and bruises. Eight advantages of Henan fireproof rolling shutter door: energy saving: two key technologies realize energy saving. First of all, the door opening design and double door interlock greatly shorten the door opening cycle. For clean rooms, the shortening of the door opening cycle can reduce the indoor air loss and improve the insulation capacity. In addition, there are double rows of encrypted sealing brushes inside the column of the fast door, and the pvc base card design makes installation and replacement convenient. Cost saving: The fast door is equipped with a LCD display, which will prompt when the door fails to operate, and the code or Chinese display will be displayed. This can avoid costly downtime and time-consuming technical maintenance, which greatly saves costs. Complete types: fast doors include explosion-proof fast doors, wind resistant fast doors, zippered fast doors (also called anti-collision automatic reset fast doors). Rich functions: Henan explosion-proof rolling shutter door can be linked with the air shower room, goods elevator, mechanical arm, assembly line, etc. High efficiency: according to the actual situation and requirements of customers on the site, provide a variety of control switches to improve the efficiency of daily operation. There are radar induction door opening, rope pulling door opening, geomagnetic induction door opening, remote control door opening, card swiping door access control door opening and other door opening methods. Safety: The bottom of Henan fast rolling shutter door is air tight and soft, and the door curtain is soft. There are safety photoelectric devices on both sides of the track. When there are people or obstacles under the door body, the door body will not fall, to ensure that people will not be touched by the door body. Steel fire resistance rolling shutter door direct deal After sales guarantee: the control system of the fast door can timely identify the fault of Henan fast rolling shutter door, and then solve the problem in time. Yuou Door&Window Technology has a special after-sales maintenance department, which can respond within 12 hours if there is a fault.

 Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

How to choose Henan fire door with good quality? Only the brand quality is excellent, can the fire door material reach a high strength and durable scale, or reach a high strength and airtight condition at the same time of fire prevention characteristics, or reach a difficult deformation quality under tropical burns, so as to eliminate the need for fire prevention. major Steel fire resistance rolling shutter door In terms of material selection, it is also advisable to adopt wood and steel materials, and fire door body made of pure materials. The price of different materials is different, and it is possible to reach the standard with both fire prevention talents. Therefore, only manufacturers with strong brand advantages can reach a comfortable level in terms of quality conditions of fire doors, and may adopt high-quality and inexpensive fire doors. Fire doors are divided into wooden fire doors and steel fire doors in shopping malls. Some consumers have a misunderstanding that the fire resistance effect of wooden fire doors will be poor rather than steel. It is necessary to change this poor idea as soon as possible. Only wooden fire doors can pass good fire resistance treatment. Steel fire resistance rolling shutter door direct deal Its flame retardant effect will be no less than that of steel fire doors. The appearance of wooden fire doors is more elegant than that of steel doors. The assembly is convenient, not to mention the existing flame retardant effect and the elegant use of decorations.

 Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

The introduction of Henan fire rolling shutter door is a kind of fire prevention and heat insulation facilities suitable for large openings of buildings. The product has played a certain role in the design and installation of technology. major Steel fire resistance rolling shutter door Fire resistant rolling shutter doors are widely used in the fire partition area of industrial and civil buildings, which can effectively prevent the spread of fire and ensure the safety of life and property. They are indispensable fire prevention facilities in modern buildings. Installation requirements and instructions for fire shutter door 1. The upper part of the opening where the shutter door is installed shall not be equipped with ventilation pipes, water pipes, etc; 2. After the roller shutter door is installed, install the suspended ceiling. The edge of the suspended ceiling should be 50mm away from the curtain plate to avoid friction; 3. During commissioning and use, it is strictly prohibited to stand at the bottom. Steel fire resistance rolling shutter door direct deal Electrical facilities shall not be removed without authorization; 4. According to the fire management regulations, the chain lubricating oil of the starting motor must not be missed during the routine fire safety inspection every quarter, which is also an important part of the omission of many property management units or fire protection units during the inspection.

 Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

Can the door of Henan Refuge Room be removed? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings, for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be equipped with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The door of the room should be Class B fireproof door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Steel fire resistance rolling shutter door The total net width of each door, emergency exit, evacuation walkway and evacuation staircase of the residential building shall be determined by calculation, and the net width of the door and emergency exit shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation outer door shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. The relevant requirements of the Code for Fire Protection Design of Henan Refuge Room Door Buildings stipulate that: 1. Evacuation in buildings with Class I and II fire resistance rating] or the linear distance from any point in the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 emergency exits to the nearest evacuation] or the emergency exit shall not be more than 30m. 2. When the evacuation door] cannot directly connect to the outdoor ground or the evacuation staircase, an evacuation corridor with a length of no more than 10m shall be used to connect to the nearest emergency exit. Steel fire resistance rolling shutter door direct deal When the place is equipped with automatic sprinkler system, the safe evacuation distance from any indoor point to the near emergency exit can be increased by 25%.

 Liaoning professional steel fireproof rolling shutter door manufacturer direct sales

Maintenance and cultivation of Henan fire rolling shutter All fire rolling shutters should be checked and tested once a week. The test content includes: fire rolling shutter escape function test. major Steel fire resistance rolling shutter door After the fire roller shutter is in the linkage state and drops to the bottom, press any manual button on both sides of the fire roller shutter, and the fire roller shutter shall be able to rise to the limit position (or drop to the bottom again after a delay). The lifting, lowering and stopping test of the manual buttons on both sides of the fire shutter. The fire rolling shutter shall be able to operate according to the instructions, and the operation shall be stable without blocking, not to mention uneven running speed of the shutter, stacking of the shutter or derailment. Test of manual emergency device. The manual zipper is used to lift the fire shutter, and the manual quick release device is used to lower the fire shutter. The fire shutter shall be able to run smoothly. Simulate the fire signal for linkage test. It is required that the fire shutter should be able to descend according to the normal procedure, and the contents and parts displayed in the fire control room should be consistent with the actual situation. Check whether the sealing of fire shutter is intact and damaged. The inspection above Henan fire rolling shutter door shall be carefully recorded, and the problems found shall be solved in a timely manner without leaving hidden dangers. Check whether the appearance of the fire shutter is intact and whether the curtain surface is damaged. Henan fire shutter door The door leaf of Henan fire shutter door cannot move: sensor failure is the major cause of the fire shutter door leaf cannot move. When such a situation occurs, be sure to check whether the sensor signal light is normal. If it is not the fault of the sensor, it may be that the wire connector is loose, the belt falls off, the controller is burned, the foreign matter is stuck, the voltage is abnormal, and so on. Pay attention to check and eliminate them one by one. Steel fire resistance rolling shutter door direct deal The door leaf of the fire rolling shutter jumps when opening and closing: the reason for this fault is very simple. If the track of the fire rolling shutter is jammed by foreign matters, it is necessary to check the tracks on both sides of the door leaf, remove the foreign matters, and the fault can be solved. The opening and closing speed of the fire shutter door leaf is too slow: customers often hear this situation. It may be that the speed adjustment of the national controller is too slow, or the belt is too loose, resulting in friction between the fire shutter door leaf and the guide rail. When handling, check these two parts. If the speed is too slow, adjust them faster. If the belt is too loose, tighten it in time.

24H

free hotline

0371-85127888 

 Henan Refuge Room Gate

Tel.: 0371-63206926

Email: [email protected]

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City