Analysis on the influence of fire resistance time of henan fire rolling shutter door on the coming of fire hazard in building fire protection design, ensuring safe evacuation of personnel is the primary premise of fire protection design, and the important standard of fire safety evacuation is time. supply Fire resistant rolling shutter door China has made detailed regulations on the setting of evacuation width, evacuation distance, various fire-fighting facilities and other elements in various fire technical specifications. These are hard standards for fire design and review, but in fact, these requirements are not isolated from each other and created out of thin air. They all serve to ensure the safe evacuation of people, The setting requirements in the specification mostly come from the calculation of the fire safety evacuation time, so understanding the fire safety evacuation time is the basis and premise for the design and installation of fire rolling shutter doors. The so-called safe evacuation of Henan fire shutter door refers to the evacuation of people to a safe area before the fire develops to threaten the safety of people, that is, to make the safe evacuation time less than the time of danger, which is the benchmark of evacuation design, and all other design elements should serve this goal. The main factors that can cause danger to people in fire are high temperature, toxic smoke, building structure collapse and so on. The high temperature is mainly caused by thermal convection and radiation. When the air temperature reaches 100 ℃, ordinary people can only endure it for more than 10 minutes. When the temperature exceeds 200 ℃, people will die within 5 minutes. The harmful gases in the smoke mainly include carbon monoxide, carbon dioxide, formaldehyde, acetaldehyde, hydrogen cyanide, etc. The common carbon monoxide content in the air as long as 1%, people will lose consciousness after breathing several times, which will lead to death. At present, a large number of polyethylene, polystyrene and other building materials will produce toxic smoke after combustion. Smoke will not only cause poisoning, but also reduce the visibility of people in dense smoke due to the dimming effect of smoke. When the visibility is less than 0.5m, the moving speed of people is equivalent to the walking speed when they lose their vision. Fire resistant rolling shutter door direct deal Henan fireproof rolling shutter door usually has a fire resistance limit much higher than the time of smoke spreading and flowing, but if flammable and combustible decoration materials are used in the evacuation passageway, it may also burn rapidly.

The installation of Henan fire rolling shutter door is prone to some problems. One problem is the strength of the transmission device of the fire rolling shutter door. The strength of the roller shutter shaft is also an important parameter of the roller shutter door. At present, there are many unqualified products with this strength, The structure of the roller shutter shaft that seriously affects the use of the fire shutter door mainly refers to the depth of the roller shutter shaft and the shaft heads at both ends plugged into the steel pipe and the depth of the structural shaft head plugged into the steel pipe should be about 110 of the shaft length, and there should be two flanges and enough welds. supply Fire resistant rolling shutter door The second problem is the depth of the guide rail. If the depth of the guide rail is not enough and the structure and materials are improper, once encountering a fire, the door curtain is easy to detach from the guide rail and cannot play a role in fire prevention. Fire resistant rolling shutter door direct deal The third problem is the pre rolling of the fire rolling shutter door. The fire rolling shutter door, especially the steel fire rolling shutter door, is relatively heavy, so a circle of pre rolling will be reserved on the reel to reduce the tension of the curtain weight on the screws. Prevent a curtain from cracking.

The advantages and disadvantages of the products of Henan fire rolling shutter manufacturers The fire rolling shutter is usually located at the poor entrance of the building, which plays a role in fire prevention, heat insulation and smoke dispersion. The fireproof rolling shutter door is a useful time to isolate the fire source when a fire occurs and provide a useful escape for employees. supply Fire resistant rolling shutter door However, the inferior fire rolling shutter door will not only not intercept the fire source, but also increase the fire. Therefore, the advantages and disadvantages of the fire rolling shutter door are also quite important. Henan fire rolling shutter door The rolling shutter door will stop landing when landing to the required height, which is to avoid people who have not had time to escape being trapped inside the rolling shutter door. Fire resistant rolling shutter door direct deal If the inferior rolling shutter doors were all lowered, the surviving victims would be trapped inside and become unnecessary casualties. Recommended reading: The fire hour and temperature resistance limit of some fire rolling shutter doors are strictly defined in the fire rolling shutter door specification. Therefore, excellent guaranteed fire rolling shutter doors must be used when adopting and purchasing rolling shutter doors.

Control Procedure for Internal Quality Management System of Henan Refuge Room Door Manufacturer 1. Purpose To conduct regular internal quality audits to verify the quality activities and related results. Stone composite procedure documents: CCCF-HZFH-02 (A/O) Rules for the Implementation of Compulsory Product Certification, Fire Protection Products, Fire Resistant Components of Buildings and other quality documents, and take corrective measures in a timely manner, So as to make the quality management system operate effectively and ensure that the product consistency meets the requirements of relevant approval rules. 2. The scope is applicable to the audit of our internal quality management system. 3. Responsibilities: The quality director shall lead the internal quality audit work, and the audit team leader shall organize the internal quality audit work under the centralized management of the office, with the cooperation of each department. Henan Refuge Room 4. Procedure (1) Audit frequency The internal quality management system of each department shall be audited at least once a year according to the following procedures. supply Fire resistant rolling shutter door In case of major quality accident or other special reasons, the quality director shall decide to conduct targeted additional audit. (2) The Audit Planning Office shall propose the "Annual Internal Quality Management System Audit Plan" every year according to the actual situation and importance of audit activities, which shall be approved and implemented by the quality director. (3) Auditors The auditors shall have the qualification of internal auditors and have no direct responsibility for the audited activities, and shall be appointed by the General Manager. For the temporary additional audit, the quality director shall specify the audit team leader and auditors. (4) Before each audit, the office shall prepare the "audit schedule plan", which shall be approved by the person in charge of quality. The audit team leader reviews the documents and assigns tasks to the auditors, who prepare the audit checklist. (5) Audited department and audit schedule; Purpose, scope and basis of audit; Audit content and specific time arrangement; Division of auditors, etc. Fire resistant rolling shutter door direct deal The audit schedule shall be sent by the audit team leader to the audited department one week in advance. After receiving the audit schedule, the audited department can notify the audit team leader in advance if there is any objection. After negotiation, it can make appropriate adjustments.

Henan fire door technical requirements Wooden fire door is a door with certain fire resistance performance, which is made of fire-resistant wood or fire-resistant wood products as door frame, door leaf framework, door leaf panel. If the door leaf is filled with materials, it is filled with fire insulation materials that are non-toxic and harmless to human body, and is equipped with fire hardware accessories. supply Fire resistant rolling shutter door The overlapping size of door leaf and door frame shall not be less than 12mm; The fit clearance between the door leaf and the hinge side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The fit clearance between the door leaf and the locked side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The clearance between the door leaf and the upper frame shall not be greater than 3mm; The gap between two or more door leaves shall not be greater than 3mm; The movable clearance between the door leaf and the lower frame or ground shall not be greater than 9mm; The gap between the door leaf and the door frame binding surface: the gap between the door leaf and the binding surface of the door frame on the hinge side, the lock side and the upper frame shall not be greater than 3mm; The plane height difference between the door leaf and the door frame: On the opening surface of the fire door, the plane height difference between the door frame and the door leaf of Tianjin Telescopic Barcode Reader should not be greater than 1mm. Wooden fireproof door refers to the door frame, door leaf framework and door leaf panel made of wood or wood products, and the fire resistance limit of the door reaches the specified value. Some small deviations between wooden fireproof doors cannot be wrong. Maybe it is a small detail problem, which may fail to meet the standard. Fire resistant rolling shutter door direct deal The materials used for Henan fire door are compared first. The fire door has a simple structure and is mainly composed of four parts: door closer, door panel materials (including 06 and 08), door frame materials, and fire panels. Grade A fireproof door is generally made of 08 material with good quality. Its normal service life is 5-8 years. The iron material of the door panel is thick. For the fireproof door with the same thickness, the weight of Grade A fireproof door is greater than that of Grade B.

Precautions for Henan fire doors There are many types of fire doors, such as glazed fire doors, stainless steel fire doors, and ordinary steel fire doors. However, the installation methods are basically the same, depending on the site conditions. Some common installation parameters must be noted. 1、 The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2、 The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3、 No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. 4、 When installing the fire door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted. The connection and anchorage can be carried out after there is no error. 5、 The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. 6、 Door closers must be installed on fire doors, and sequencers must be installed on opposite doors. 7、 Hardware accessories such as handle and fire lock on the fire door must be complete; 8、 It is required that the clearance from the ground plane shall not be greater than 5mm. Henan fire door steel fire door is moderate in price, but it is heavy, hard to open, monotonous in style, and not beautiful enough, so it is mostly used in industrial buildings and general grade civil buildings, or parts of buildings that have low aesthetic requirements and low pedestrian flow at ordinary times (such as machine rooms, garages, etc.). supply Fire resistant rolling shutter door On the contrary, wood fire doors have light deadweight, flexible opening and closing, good decorative appearance and many patterns, but their prices are high, and they are mostly used in middle and high grade civil buildings or important occasions in buildings. Generally, the applicable size of large opening for each fireproof door is about 3.3m high, 1.1m wide for single leaf and 3.0m wide for double leaf. In engineering design, in addition to setting fire doors in strict accordance with the occasions, positions, widths, grades and opening directions required by the specifications, attention should also be paid to the fact that fire doors are generally set on the evacuation path (such as stairwells, antechambers, walkways, etc.), and that a little carelessness in the design of building plane details may cause the door leaf to block the evacuation path and reduce its effective width after opening, Violation of basic requirements for personnel evacuation. Fire resistant rolling shutter door direct deal This phenomenon is particularly prominent at the turning point of the evacuation path and in high-rise residential buildings, which should be paid attention to and avoided.