
Henan fireproof door installation method The fireproof door is divided into steel fireproof door and wooden fireproof door according to the material. There are some differences in the installation method of the two fireproof doors. supply Fire resistant roller shutter The fire rating is slightly different. You must pay attention to the details when installing. First of all, when installing the wooden fireproof door, the size of the door frame should be 20mm smaller than the opening, and the lower foot of the door frame should be buried 20mm below the ground. The door frame should be firmly fixed with the wall, and perpendicular to the corner. The vertical frame and bracing frame shall be straight and at the same angle to avoid planing and sawing. There shall be no less than 3 fixed points on both sides of the door frame, and the spacing shall not be greater than 800mm. Secondly, during the installation of the steel fire door, considering the bending deformation of the door frame, it is necessary to support the door frame with wooden braces in the width direction of the door frame. The lower foot of the door frame is buried 20 mm below the ground, and then the door frame is welded with the embedded parts on the wall. Then make a hole in the wall at the upper corner of the door frame, and pour concrete of cement, sand and expanded perlite (1:2:5), which can be used after the concrete has set. Fire resistant roller shutter Manufacturer Requirements for airtightness of fire doors: there are clear requirements for the size of the gap at each overlap of fire doors: for steel fire doors, the overlap between the leaf and the door frame shall not be less than 10mm, and the gap between the leaf and the door frame on both sides shall not be more than 4mm. The gap after the installation of the fire door cannot be too large, otherwise the airtightness of the fire door is difficult to guarantee, and it is difficult to reflect its role in restraining fire and smoke spread under fire conditions.

Henan fire door is an important part of fire fighting equipment. Fire door is an important part of fire fighting equipment and an important part of social fire prevention. Therefore, the quality and use of fire door is the key to the success of fire prevention. supply Fire resistant roller shutter The fire resistance limit of Class C fireproof door is 0.6h) 1. The inspection door on the wall of equipment tube well, ventilation duct and garbage duct shall be Class C fireproof door. 2. The front door of the garbage way shall be Class C fireproof door. 3. When the cable shaft and pipe shaft are set in the front room of the smoke proof staircase and the shared front room, the inspection door on the shaft wall shall be Class C fireproof door. 4. The door connecting the substation and distribution substation should be Class C fireproof door. The door directly leading to the outdoor of the substation shall be Class C fireproof door. 5. The cable well and pipe well shall be separated from each other every 2~3 floors by incombustible materials equivalent to the fire resistance limit of the floor. The inspection door on the shaft wall shall be Class C fire door. 6. The garbage hopper shall be made of incombustible and corrosion-resistant materials and can be closed and sealed by itself; Garbage hoppers of high-rise buildings and super high-rise buildings shall be located in the front room of the garbage chute, which shall be equipped with Class C fireproof doors. 7. The telecommunication room shall adopt outward opening Class C fireproof door with a width of more than 0.7m. 8. The oxygen busbar room with the oxygen delivery capacity not exceeding 60m3/h can be set in the user's workshop with the fire resistance rating not lower than Grade III and close to the external wall. The wall with the height of 2.5m and the fire resistance rating not lower than 1.5h and the Grade C fire door should be used to separate it from other parts of the workshop. 9. The partition wall of the collection warehouse and exhibition room shall be non combustible. The compartments in the fire compartment shall be separated by partition walls with a fire resistance rating of not less than 3h and Class B fire doors. The enclosure structure of closed shaft shall be non combustible and Class C fireproof door. 10. The fire resistance limit of partition walls between production rooms with explosion risk shall not be less than 1.5h. Fire resistant roller shutter Manufacturer The door is Class C fireproof door. 11. When the oxygen generation station building or liquid oxygen gasification station building and oxygen filling station building are arranged in the same building, the noncombustible partition wall with a fire resistance rating of not less than 1.5h and Class C fire door shall be used, and they shall be connected through the walkway. 12. The doors on the partition walls between the oxygen compressor room and the bottle filling room, as well as the purification room, the oxygen storage bag room, the oxygen storage tank room, the liquid oxygen storage tank room and other rooms shall be Class C fireproof doors.

Why is Henan fire rolling shutter an indispensable facility? Why is fire rolling shutter an indispensable facility. supply Fire resistant roller shutter The types of fire rolling shutter doors in Henan mainly include composite steel fire rolling shutter (fire and smoke prevention), inorganic super grade fire rolling shutter (double track double shutter), steel composite water spray steam fog fire rolling shutter, steel composite lateral fire rolling shutter, steel composite horizontal fire rolling shutter, inorganic super grade folding fire rolling shutter and fire rolling shutter with various doors. The fireproof rolling shutter door, as well as the firewall, functions as a horizontal fireproof partition. It is composed of 13 parts, such as shutter, base plate, guide rail, support, reel, box, control box, door rolling machine, limiter, door header, manual quick release switch device, button switch and safety device, and is generally installed at the position that is not convenient for firewall separation. For example, open elevator halls, escalators, wide business halls of department stores, exhibition halls of exhibition buildings, and parts of buildings with large openings that cannot use fireproof doors and windows. Fire resisting rolling shutter door has been widely used in building engineering to make fire separation. Fire resistant roller shutter Manufacturer Henan fireproof rolling shutter door is an indispensable fire prevention facility in modern high-rise buildings. In addition to the function of ordinary door, the fireproof door has the special functions of fire prevention, smoke separation, suppression of fire spread, and protection of personnel evacuation. It is widely used in high-rise buildings, large shopping malls and other crowded places.

What are the requirements for the opening direction of the door of Henan Refuge Room? Fire doors play an important role in life. The opening direction of fire doors is very important. The Code for Fire Protection Design of Tall Buildings has clearly stipulated that the stairwell should be opened in the direction of evacuation, such as the stairwell should be opened in the direction of the staircase lobby, so as to facilitate the evacuation of people. supply Fire resistant roller shutter In addition, the front room is generally a place of refuge and an evacuation passageway. In case of a fire, positive pressure air supply is required. If it is not installed in the above opening direction, the air pressure may open the fire door, causing fire and smoke leakage. 4. Classification 4.1 According to the number of door leaves, there are steel single fire door and steel double fire door. 4.2 According to the door leaf structure, there are steel fire door with glass lining, steel fire door without glass lining, steel fire door with bright window and steel fire door without bright window. Fire resistant roller shutter Manufacturer According to the fire resistance limit, there are Class A fire doors, Class B fire doors and Class C fire doors.

The classification and function of Henan fire rolling shutter door The fire rolling shutter door plays the same role as the firewall in horizontal fire separation. It is composed of 13 parts, such as shutter, base plate, guide rail, support, reel, box, control box, door roller, limiter, door header, manual quick release switch device, button switch and safety device, It is generally installed at the position that is inconvenient to be separated by firewall. supply Fire resistant roller shutter For example, open elevator halls, escalators, wide business halls of department stores, exhibition halls of exhibition buildings, and parts of buildings with large openings that cannot use fireproof doors and windows. Fire resisting rolling shutter door has been widely used in building engineering to make fire separation. Fire resistant roller shutter Manufacturer Fire resisting rolling shutter door is an indispensable fire prevention facility in modern high-rise buildings. In addition to the function of ordinary door, fire resisting door has special functions of fire prevention, smoke separation, suppression of fire spread, and protection of personnel evacuation. It is widely used in high-rise buildings, large shopping malls and other crowded venues. Classified fire rolling shutter doors mainly include composite steel fire rolling shutter (fire and smoke prevention), inorganic super grade fire rolling shutter (double track double shutter), steel composite water spray steam fog fire rolling shutter, steel composite lateral fire rolling shutter, steel composite horizontal fire rolling shutter, inorganic super grade folding fire rolling shutter and fire rolling shutter with various doors.