上海龙凤shlf1314足浴

Hello! Welcome to the website of Henan Rui'andun Door Industry Co., Ltd!

 Henan fireproof door

contact us

Tel.: 0371-85127888

Fax: 0371-62495556

Mobile: 17788121396

Email: [email protected]

website: www.00151.cn

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City

Price of fire shutter supplied by Zhumadian

Your current location: home page > Hot information

Price of fire shutter supplied by Zhumadian

2022-12-14
 Price of fire shutter supplied by Zhumadian

The operation method of Henan fire doors is recognized by the laboratory of the Ministry of Economy of the Ministry of Fire Protection. According to the new version of the standard for fire doors GB_12955-2008 implemented on January 1, 2009, those who pass the fire resistance test method of fire doors and obtain the registration certificate and authorization mark issued by the Bureau of Standards and Inspection of the Ministry of Economy are called fire doors. supply Fire resistant roller shutter The fire door defined in the American NFPA and IBC codes is "the combination of any fire door leaf, door frame, hardware and other accessories that can jointly provide a certain degree of fire protection at the opening." Operation method Henan fire door widely carries out publicity and education on the use, maintenance and management of fire prevention facilities within the jurisdiction of the fire department in charge, Efforts should be made to improve people's awareness of fire protection and self-protection; Extensive publicity, education and training on fire protection and umbrella protection knowledge shall be carried out for units installed with fire door maintenance, so as to make every employee understand the basic knowledge of the use, maintenance and management of fire door maintenance, and consciously participate in the maintenance and management of the Gate of Life, so as to keep them in a state of combat readiness at all times; The fire door maintenance purpose, function and good use status and basic requirements for use shall be posted on the fire door maintenance, and the words "normally closed fire door maintenance, please close at any time" shall be written on the conspicuous position of the normally closed fire door maintenance, so that customers and the masses can understand the basic knowledge of fire door maintenance. Fire resistant roller shutter Price Carry out publicity activities to protect fire-fighting facilities and equipment, and mobilize everyone to participate in the protection of fire-fighting facilities such as fire door maintenance.

 Price of fire shutter supplied by Zhumadian

Henan fire door is an important part of fire fighting equipment. Fire door is an important part of fire fighting equipment and an important part of social fire prevention. Therefore, the quality and use of fire door is the key to the success of fire prevention. supply Fire resistant roller shutter The fire resistance limit of Class C fireproof door is 0.6h) 1. The inspection door on the wall of equipment tube well, ventilation duct and garbage duct shall be Class C fireproof door. 2. The front door of the garbage way shall be Class C fireproof door. 3. When the cable shaft and pipe shaft are set in the front room of the smoke proof staircase and the shared front room, the inspection door on the shaft wall shall be Class C fireproof door. 4. The door connecting the substation and distribution substation should be Class C fireproof door. The door directly leading to the outdoor of the substation shall be Class C fireproof door. 5. The cable well and pipe well shall be separated from each other every 2~3 floors by incombustible materials equivalent to the fire resistance limit of the floor. The inspection door on the shaft wall shall be Class C fire door. 6. The garbage hopper shall be made of incombustible and corrosion-resistant materials and can be closed and sealed by itself; Garbage hoppers of high-rise buildings and super high-rise buildings shall be located in the front room of the garbage chute, which shall be equipped with Class C fireproof doors. 7. The telecommunication room shall adopt outward opening Class C fireproof door with a width of more than 0.7m. 8. The oxygen busbar room with the oxygen delivery capacity not exceeding 60m3/h can be set in the user's workshop with the fire resistance rating not lower than Grade III and close to the external wall. The wall with the height of 2.5m and the fire resistance rating not lower than 1.5h and the Grade C fire door should be used to separate it from other parts of the workshop. 9. The partition wall of the collection warehouse and exhibition room shall be non combustible. The compartments in the fire compartment shall be separated by partition walls with a fire resistance rating of not less than 3h and Class B fire doors. The enclosure structure of closed shaft shall be non combustible and Class C fireproof door. 10. The fire resistance limit of partition walls between production rooms with explosion risk shall not be less than 1.5h. Fire resistant roller shutter Price The door is Class C fireproof door. 11. When the oxygen generation station building or liquid oxygen gasification station building and oxygen filling station building are arranged in the same building, the noncombustible partition wall with a fire resistance rating of not less than 1.5h and Class C fire door shall be used, and they shall be connected through the walkway. 12. The doors on the partition walls between the oxygen compressor room and the bottle filling room, as well as the purification room, the oxygen storage bag room, the oxygen storage tank room, the liquid oxygen storage tank room and other rooms shall be Class C fireproof doors.

 Price of fire shutter supplied by Zhumadian

Relevant requirements for fire protection of the door of Henan Refuge Room What kind of products are qualified when the door of Henan Refuge Room passes the fire protection? Here are some examples: 1. Filling materials: the filling materials must meet the requirements of combustion performance A1 specified in GB8624-2006. At the same time, it meets the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 2. Material thickness: door leaf material shall be no less than 0.8mm, door panel material shall be no less than 0.8mm, door frame plate shall be no less than 1.2mm, hinge plate shall be no less than 3.0mm, reinforcement without screw holes shall be no less than 1.2mm, and reinforcement with screw holes shall be no less than 3.00mm. supply Fire resistant roller shutter The door of Henan refuge room 3. The adhesive shall meet the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 4. Dimensional deviation: the height of the door leaf shall not exceed 2mm, the width of the door leaf shall not exceed 2mm, the thickness of the door leaf shall be between - 1mm and+2mm, the height of the clipping opening in the door frame shall not exceed 3mm, the width of the clipping opening in the door frame shall not exceed 2mm, and the width of the side wall of the door frame shall not exceed 2mm. 5. Geometric tolerance: the length difference between the two diagonals of the door leaf shall be less than or equal to 3mm, The distortion of the door leaf shall be less than or equal to 5mm, the curvature of the door leaf in the width direction shall be less than 2%, the curvature of the door leaf in the height direction shall be less than 2%, and the length difference between the two diagonals of the inner cutting opening shall be less than or equal to 3mm. 6. Fit tolerance: the overlap size between Manshan and the door frame is less than or equal to 12mm, the fit clearance between the door leaf and the door frame at the hinge side shall not be greater than the size tolerance specified in the design drawing, and the fit clearance between the door leaf and the door frame at the lock side shall not be greater than the size tolerance specified in the design drawing. Fire resistant roller shutter Price The clearance between the door leaf and the upper frame shall be less than or equal to 3mm, the clearance between the double leaf and multi leaf door leaves shall be less than or equal to 3mm, the clearance between the door leaf and the lower frame or the ground shall be less than or equal to 9mm, the clearance between the binding surface of the door leaf and the side of the door frame with hinges shall be less than or equal to 3mm, the clearance between the binding surface of the door leaf and the side of the door frame with locks shall be less than or equal to 3mm, and the clearance between the binding surface of the door leaf and the upper frame of the door frame shall be less than or equal to 3mm, The plane height difference between the door frame and the door leaf is less than or equal to 1mm.

 Price of fire shutter supplied by Zhumadian

Placement requirements, maintenance methods and precautions of Henan fire door at ordinary times Maintenance methods and precautions of fire door at ordinary times. supply Fire resistant roller shutter When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 2. Do not pull off the fireproof seal, or it will lose its function in case of fire. Henan fireproof doors and windows cannot be left open for a long time, which will damage the door closer and make it lose its function. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 3. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 4. Henan fireproof doors and windows shall be protected from outdoor sunshine for a long time to prevent the fireproof door from being heated. Fire resistant roller shutter Price It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. After splashing with water, wipe it with dry cloth to avoid local expansion. The fire door closer must be replaced in case of oil leakage.

24H

free hotline

0371-85127888 

 Henan Refuge Room Gate

Tel.: 0371-63206926

Email: [email protected]

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City