Henan fireproof door is generally set in the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Inspection doors of vertical pipe shafts such as cable shafts, pipe shafts, smoke exhaust ducts, garbage ducts, etc. Henan fire door (3) divides the fire compartment, controls the fire wall and the door on the fire partition of the building area of the compartment. major Fire resistant roller shutter When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (4) Code (such as GB50016-2014 Code for Fire Protection Design of Buildings) or partition door with special requirements for fire and smoke prevention. For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. Fire resistant roller shutter direct deal There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. Fire and burglar proof doors are often used as household doors in high-rise and high-grade residential buildings. GB 12955-2008 Requirements for Fire Resistance of Fire Doors Fire doors are an important part of fire fighting equipment and an important part of social fire prevention. Fire doors should be equipped with fire door closers or door closers that allow normally open fire doors to automatically close the door leaves in case of fire (except for special parts, such as pipeline shaft doors, etc.). That is to say, except for some special parts, such as pipeline well doors, which do not need to install door closers, other parts need to install fire door closers.

The use and maintenance of henan fire rolling shutter door henan fire rolling shutter door is a very important fire protection facility for fire compartment and fire partition in public places. major Fire resistant roller shutter It is also a fire protection product with comprehensive mechanical and electrical performance, so the installed fire shutter should always be kept in normal condition. During the use of Henan fire rolling shutter door, special equipment shall be used and kept by special personnel, and have certain basic knowledge of electricians and machinery. During the operation of fire rolling shutter door, the operator shall not leave the operation site without authorization, and shall pay close attention to the opening and closing conditions and implementation conditions. No one is allowed to stand or walk under the shutter when opening and closing. To prevent travel switch failure, roller shutter stuck, motor blocked and other accidents. The steel fire shutter of fire compartment and fire partition is not frequently used at ordinary times. In case of fire in the area, the shutter should be put into use effectively. The automatic control fire shutter with linkage control and central control center control must be carried out according to a set of control command procedures. Fire rolling shutter door.jpg The basic function of Henan fire rolling shutter door is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. This product is very good at preventing ultraviolet rays. The temperature is relatively high in summer, and one of these products can prevent ultraviolet rays. The ultraviolet radiation is destructive to human skin, so it seems very important. This product has helped me. This product has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. Fire resistant roller shutter direct deal We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

Precautions for Henan fire doors There are many types of fire doors, such as glazed fire doors, stainless steel fire doors, and ordinary steel fire doors. However, the installation methods are basically the same, depending on the site conditions. Some common installation parameters must be noted. 1、 The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2、 The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3、 No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. 4、 When installing the fire door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted. The connection and anchorage can be carried out after there is no error. 5、 The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. 6、 Door closers must be installed on fire doors, and sequencers must be installed on opposite doors. 7、 Hardware accessories such as handle and fire lock on the fire door must be complete; 8、 It is required that the clearance from the ground plane shall not be greater than 5mm. Henan fire door steel fire door is moderate in price, but it is heavy, hard to open, monotonous in style, and not beautiful enough, so it is mostly used in industrial buildings and general grade civil buildings, or parts of buildings that have low aesthetic requirements and low pedestrian flow at ordinary times (such as machine rooms, garages, etc.). major Fire resistant roller shutter On the contrary, wood fire doors have light deadweight, flexible opening and closing, good decorative appearance and many patterns, but their prices are high, and they are mostly used in middle and high grade civil buildings or important occasions in buildings. Generally, the applicable size of large opening for each fireproof door is about 3.3m high, 1.1m wide for single leaf and 3.0m wide for double leaf. In engineering design, in addition to setting fire doors in strict accordance with the occasions, positions, widths, grades and opening directions required by the specifications, attention should also be paid to the fact that fire doors are generally set on the evacuation path (such as stairwells, antechambers, walkways, etc.), and that a little carelessness in the design of building plane details may cause the door leaf to block the evacuation path and reduce its effective width after opening, Violation of basic requirements for personnel evacuation. Fire resistant roller shutter direct deal This phenomenon is particularly prominent at the turning point of the evacuation path and in high-rise residential buildings, which should be paid attention to and avoided.

Henan fire rolling shutter door is generally installed in the place determined by the process. In addition to the firewall, the fire rolling shutter door should be installed in the two fire compartments where there is no firewall. It is generally located at the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Divide the fire compartment and control the fire wall and the door on the fire partition in the building area of the compartment. When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (3) Code (such as GB50045-95 Code for Fire Protection Design of High rise Civil Buildings) or partition door with special requirements for fire and smoke prevention. major Fire resistant roller shutter For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. Fire resistant roller shutter direct deal The limited area of Henan fire shutter door special grade fire shutter In the use of special grade fire shutter, because it is mainly used in the rapid formation of fire separation areas, and is mostly set in applications with large space, as a visible fire separation device, generally in the production of fire shutter, fire shutter will be painted with a more striking color, It can not only make the fireproof rolling shutter have a better decorative effect after being folded, but also can remind people of the escape route in fire accidents through eye-catching and penetrating colors in the fire compartment, so as to buy time for effective escape.

Can the door of Henan Refuge Room be removed? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings, for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be equipped with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The door of the room should be Class B fireproof door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Fire resistant roller shutter The total net width of each door, emergency exit, evacuation walkway and evacuation staircase of the residential building shall be determined by calculation, and the net width of the door and emergency exit shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation outer door shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. The relevant requirements of the Code for Fire Protection Design of Henan Refuge Room Door Buildings stipulate that: 1. Evacuation in buildings with Class I and II fire resistance rating] or the linear distance from any point in the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 emergency exits to the nearest evacuation] or the emergency exit shall not be more than 30m. 2. When the evacuation door] cannot directly connect to the outdoor ground or the evacuation staircase, an evacuation corridor with a length of no more than 10m shall be used to connect to the nearest emergency exit. Fire resistant roller shutter direct deal When the place is equipped with automatic sprinkler system, the safe evacuation distance from any indoor point to the near emergency exit can be increased by 25%.