Henan fireproof door installation method The fireproof door is divided into steel fireproof door and wooden fireproof door according to the material. There are some differences in the installation method of the two fireproof doors. major Fire resistant roller shutter The fire rating is slightly different. You must pay attention to the details when installing. First of all, when installing the wooden fireproof door, the size of the door frame should be 20mm smaller than the opening, and the lower foot of the door frame should be buried 20mm below the ground. The door frame should be firmly fixed with the wall, and perpendicular to the corner. The vertical frame and bracing frame shall be straight and at the same angle to avoid planing and sawing. There shall be no less than 3 fixed points on both sides of the door frame, and the spacing shall not be greater than 800mm. Secondly, during the installation of the steel fire door, considering the bending deformation of the door frame, it is necessary to support the door frame with wooden braces in the width direction of the door frame. The lower foot of the door frame is buried 20 mm below the ground, and then the door frame is welded with the embedded parts on the wall. Then make a hole in the wall at the upper corner of the door frame, and pour concrete of cement, sand and expanded perlite (1:2:5), which can be used after the concrete has set. Fire resistant roller shutter direct deal Requirements for airtightness of fire doors: there are clear requirements for the size of the gap at each overlap of fire doors: for steel fire doors, the overlap between the leaf and the door frame shall not be less than 10mm, and the gap between the leaf and the door frame on both sides shall not be more than 4mm. The gap after the installation of the fire door cannot be too large, otherwise the airtightness of the fire door is difficult to guarantee, and it is difficult to reflect its role in restraining fire and smoke spread under fire conditions.

Henan fire door selection method Fire door is particularly important as a family fire protection, but when you buy low-quality fire door, the fire door is no longer fireproof, what should you do? The fire department of our city investigated and destroyed a batch of inferior fire doors with honeycomb paper instead of fireproof filler materials. Here, the firefighters introduced some tips on how to select and purchase high-quality fire doors. According to the regulations, steel and wood fire doors can be divided into Class A, Class B and Class C according to the fire resistance limit. The fire resistance limit requirements are 90 minutes, 60 minutes and 30 minutes respectively. In addition, the wood used to make wood fire doors needs drying and flame retardant treatment, and the hardware used must also be fire hardware. major Fire resistant roller shutter There are five ways to choose high-quality fire doors: one is to check the appearance, high-quality steel fire doors are firmly welded, and the welding spots are evenly distributed; The external surface shall be sprayed flat and smooth; There shall be product mark, quality inspection mark and quality certification (approval) mark at the specified position. Fire resistant roller shutter direct deal The qualified wooden fireproof door shall be intact without damage, and the surface shall be clean without plane marks, burrs and hammer marks; Corner cutting and butt joint shall be tight and flat. The second way is to check the figures. The overall dimensions of qualified products should be less than or equal to the overall dimensions in the sample description, the door leaf thickness should be greater than or equal to the door leaf thickness in the sample description, the door frame sidewall width should be greater than or equal to the door frame sidewall width in the sample description, and the overall dimensions of fire-resistant glass should be less than or equal to the overall dimensions of fire-resistant glass in the sample description, The thickness of fireproof glass shall be equal to or greater than the thickness of fireproof glass in the sample description.

Henan fireproof rolling shutter door is developing rapidly. Henan fireproof rolling shutter door style and measurement design considerations. The fireproof rolling shutter door is widely used in commercial buildings, workshops and underground garages. The specific installation standards are as follows: measurement design: step one: general classification of roller shutter installation. Self inspection of fire shutter: manual operation mode: whether a circular iron chain set in the storage box at one side of the shutter can be found to operate the lowering and rolling. major Fire resistant roller shutter When the installation form is wall side installation: when there are embedded parts (steel plates) in the building, after cleaning the installation datum plane, check and verify whether the size and external position of the embedded parts are suitable for the installation drawing design. If the design requirements are appropriate, this is the datum plane for the installation of large and small supports. Fire resistant roller shutter direct deal The facing bricks around the wall projections shall be cut and matched with the whole brick, and the edges shall be clean. (Check the date of delivery and the date of maintenance; carbon dioxide, dry powder and clean gas extinguishers are outdated if they have been delivered for 5 years or maintained for 2 years; foam extinguishers are outdated if they have been delivered for 3 years or maintained for 1 year, and they need to be sent to the fire extinguisher factory or professional maintenance unit for maintenance). Henan fireproof rolling shutter door After the Henan fireproof rolling shutter door is installed, the ceiling edge should be 50mm away from the curtain plate to avoid friction; c. The foundation dimensions of rolling shutter doors and parts shall be measured, which shall be consistent with the requirements of the design institute.

Henan fire door development prospects 1. The fire door industry is also an emerging industry, with huge market capacity and market potential. 2. Due to the high qualification threshold of fire doors, there are not many manufacturers that can really enter the fire door industry, but also Grade C fire doors Grade C fire doors Henan fire doors. According to incomplete statistics, there are more than 1000 fire door enterprises. major Fire resistant roller shutter This does not include those family workshop type processing units. The products produced by these processing units are of different grades, with prices ranging from hundreds to thousands of yuan. 3. The market pattern in the industry has not been formed yet. There are few large enterprises and brands, and there is no leading brand. The research, development and production of fire door products have played a positive role in ensuring the safety of people's lives and property. China's fire door market started late, but developed rapidly. In recent years, some European and American enterprises have actively participated in the competition in the Chinese fire door market, especially European enterprises, which are trying to make European fire doors occupy more of the Chinese market. Fire resistant roller shutter direct deal In the face of competitors, we must face up to the current situation. On the one hand, we should learn from our competitors modestly, and on the other hand, we should strive to enhance our own strength. Fire door manufacturers in China are facing a huge challenge. Who can seize the opportunity in this challenge will become a winner in the market.

The operation method of Henan fire doors is recognized by the laboratory of the Ministry of Economy of the Ministry of Fire Protection. According to the new version of the standard for fire doors GB_12955-2008 implemented on January 1, 2009, those who pass the fire resistance test method of fire doors and obtain the registration certificate and authorization mark issued by the Bureau of Standards and Inspection of the Ministry of Economy are called fire doors. major Fire resistant roller shutter The fire door defined in the American NFPA and IBC codes is "the combination of any fire door leaf, door frame, hardware and other accessories that can jointly provide a certain degree of fire protection at the opening." Operation method Henan fire door widely carries out publicity and education on the use, maintenance and management of fire prevention facilities within the jurisdiction of the fire department in charge, Efforts should be made to improve people's awareness of fire protection and self-protection; Extensive publicity, education and training on fire protection and umbrella protection knowledge shall be carried out for units installed with fire door maintenance, so as to make every employee understand the basic knowledge of the use, maintenance and management of fire door maintenance, and consciously participate in the maintenance and management of the Gate of Life, so as to keep them in a state of combat readiness at all times; The fire door maintenance purpose, function and good use status and basic requirements for use shall be posted on the fire door maintenance, and the words "normally closed fire door maintenance, please close at any time" shall be written on the conspicuous position of the normally closed fire door maintenance, so that customers and the masses can understand the basic knowledge of fire door maintenance. Fire resistant roller shutter direct deal Carry out publicity activities to protect fire-fighting facilities and equipment, and mobilize everyone to participate in the protection of fire-fighting facilities such as fire door maintenance.

The installation of Henan fire rolling shutter door is prone to some problems. One problem is the strength of the transmission device of the fire rolling shutter door. The strength of the roller shutter shaft is also an important parameter of the roller shutter door. At present, there are many unqualified products with this strength, The structure of the roller shutter shaft that seriously affects the use of the fire shutter door mainly refers to the depth of the roller shutter shaft and the shaft heads at both ends plugged into the steel pipe and the depth of the structural shaft head plugged into the steel pipe should be about 110 of the shaft length, and there should be two flanges and enough welds. major Fire resistant roller shutter The second problem is the depth of the guide rail. If the depth of the guide rail is not enough and the structure and materials are improper, once encountering a fire, the door curtain is easy to detach from the guide rail and cannot play a role in fire prevention. Fire resistant roller shutter direct deal The third problem is the pre rolling of the fire rolling shutter door. The fire rolling shutter door, especially the steel fire rolling shutter door, is relatively heavy, so a circle of pre rolling will be reserved on the reel to reduce the tension of the curtain weight on the screws. Prevent a curtain from cracking.