Maintenance methods and precautions of Henan fireproof door Maintenance methods and precautions of Henan fireproof door: 1. Door leaf and door frame shall be placed horizontally and stacked indoors with backing plates, and the frame and door leaf shall be stacked separately. 2. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 3. It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 4. Try to avoid outdoor sunshine for a long time to prevent the fire door from being heated. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. high quality Class A fireproof window After splashing with water, wipe it with dry cloth to avoid local expansion. 6. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. 7. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. 8. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 9. Do not support the door for a long time without closing it, which will damage the door closer and make it lose its function. 10. Do not pull off the fireproof seal, or it will lose its function in case of fire. 11. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 12. When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. 13. The fire door closer must be replaced in case of oil leakage. Class A fireproof window Manufacturer Then, the Henan Fireproof Doors and Windows Editor summarized the above contents into the following points, and you must remember! Do not always open: it is prohibited to manually keep the normally closed fire doors set on the evacuation walkway, the front room of the smoke proof staircase or the shared front room open during the use process to become "normally open" fire doors. In case of a fire, such "normally open" fire doors can not prevent smoke and fire; Regular inspection: frequently check the integrity of the fire door, check whether the door closer and sequencer are in good use, whether the fire door can be closed automatically in order, and whether the screws on the hinge and hinge are loose. If damaged, immediately organize maintenance; Decoration: one-sided pursuit of decoration effect, canceling the fire door frame and setting only the door pocket made of ordinary wood, replacing the original frame of the door leaf with other materials, and adding decorative surface layer in a large range, thus damaging the fire retardant coating and failing to achieve fire retardant effect; Regular test: the normally open fire door shall be tested regularly to check whether its self closing control system, door closer, sequencer, release switch and other aspects are easy to use, whether it can effectively perform the self closing function in case of fire, and at the same time, it is necessary to resolutely prevent the random stacking of articles near the normally open fire door.

Henan fireproof door is generally set in the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Inspection doors of vertical pipe shafts such as cable shafts, pipe shafts, smoke exhaust ducts, garbage ducts, etc. Henan fire door (3) divides the fire compartment, controls the fire wall and the door on the fire partition of the building area of the compartment. high quality Class A fireproof window When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (4) Code (such as GB50016-2014 Code for Fire Protection Design of Buildings) or partition door with special requirements for fire and smoke prevention. For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. Class A fireproof window Manufacturer There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. Fire and burglar proof doors are often used as household doors in high-rise and high-grade residential buildings. GB 12955-2008 Requirements for Fire Resistance of Fire Doors Fire doors are an important part of fire fighting equipment and an important part of social fire prevention. Fire doors should be equipped with fire door closers or door closers that allow normally open fire doors to automatically close the door leaves in case of fire (except for special parts, such as pipeline shaft doors, etc.). That is to say, except for some special parts, such as pipeline well doors, which do not need to install door closers, other parts need to install fire door closers.

The role of Henan fire doors in fire protection We often see on the ground of some large or local places that no one is allowed to stand under the fire facilities or shelves are placed. high quality Class A fireproof window Then, the primary use of assembling fire doors is that if a fire occurs in a certain place, the rolling shutter door can stop the extension of the fire when it is put down. Usually, the fire doors in such large buildings have automatic central control systems. Once a fire occurs, you can automatically implement a series of behaviors, and the fire doors will automatically lower the fire. The following is the employment process of the automatic control system of the fire door. When a fire occurs, the smoke sensor installed on the roof receives the flag of the smoke and alarms to the central control system. After identification, the control system of the fire center connects the power supply of the fire door in the fire alarm location area, so that the fire shutter in the fire area will fall to the ground at the required rate. When the roller shutter passes to a position about 1.5 meters above the ground, stop the activity, so as to facilitate the evacuation and evacuation of employees on site. After the associated employees withdraw together, the fire door will continue to go down until it is closed. The descending rate of the fire door and the time of stay during the period can be adjusted according to the number of employees. Class A fireproof window Manufacturer It is not only such places that are equipped with fire doors, but also in some staircases, corridors and other places. Since fire is rarely generated and some fire prevention settings are easy to use, the conditions must be inspected regularly by dedicated staff.

The use and maintenance of henan fire rolling shutter door henan fire rolling shutter door is a very important fire protection facility for fire compartment and fire partition in public places. high quality Class A fireproof window It is also a fire protection product with comprehensive mechanical and electrical performance, so the installed fire shutter should always be kept in normal condition. During the use of Henan fire rolling shutter door, special equipment shall be used and kept by special personnel, and have certain basic knowledge of electricians and machinery. During the operation of fire rolling shutter door, the operator shall not leave the operation site without authorization, and shall pay close attention to the opening and closing conditions and implementation conditions. No one is allowed to stand or walk under the shutter when opening and closing. To prevent travel switch failure, roller shutter stuck, motor blocked and other accidents. The steel fire shutter of fire compartment and fire partition is not frequently used at ordinary times. In case of fire in the area, the shutter should be put into use effectively. The automatic control fire shutter with linkage control and central control center control must be carried out according to a set of control command procedures. Fire rolling shutter door.jpg The basic function of Henan fire rolling shutter door is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. This product is very good at preventing ultraviolet rays. The temperature is relatively high in summer, and one of these products can prevent ultraviolet rays. The ultraviolet radiation is destructive to human skin, so it seems very important. This product has helped me. This product still has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. Class A fireproof window Manufacturer We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

What is the difference between the normally open and normally closed fire doors of Henan fire doors? The differences between the normally open and normally closed fire doors are as follows: 1. Different meanings. The normally open fire doors are usually open, and they are automatically closed by the control system only in case of fire. It is generally used in the passage or corridor of public places. high quality Class A fireproof window Normally closed fire doors are closed under normal conditions and in case of fire, and need to be pushed open when someone walks around, so as to prevent smoke and fire and prevent the spread of fire. 2. The price is different, and the price of the normally open fire door is higher, and the system is strong. The price of normally closed fire doors is relatively low. Henan fireproof doors and windows 3. The composition is different. The normally open fireproof door consists of door leaf, door frame, door closer, sealing strip, release switch and other parts. The normally closed fireproof door is equipped with sequencer in addition to the above parts. 4. The control mode is different. The normally open fire door is controlled by the fire door release switch. The normally closed fire door does not need to be set with electric automatic control. It is mainly closed by the door closer and sequencer, that is, mechanical. Precautions for Henan fire door fire door 1. The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2. The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3. No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. Henan fireproof doors and windows 4. When installing the fireproof door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted, and then it can be connected and anchored. 5. The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. Class A fireproof window Manufacturer Henan fireproof doors and windows 6. Door closers must be installed on fireproof doors, and sequencers must be installed on opposite doors. 7. The handle, fire lock and other hardware accessories on the fire door must be complete. 8. It is required that the clearance from the ground plane shall not be greater than 5mm.