Relevant requirements for fire protection of the door of Henan Refuge Room What kind of products are qualified when the door of Henan Refuge Room passes the fire protection? Here are some examples: 1. Filling materials: the filling materials must meet the requirements of combustion performance A1 specified in GB8624-2006. At the same time, it meets the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 2. Material thickness: door leaf material shall be no less than 0.8mm, door panel material shall be no less than 0.8mm, door frame plate shall be no less than 1.2mm, hinge plate shall be no less than 3.0mm, reinforcement without screw holes shall be no less than 1.2mm, and reinforcement with screw holes shall be no less than 3.00mm. high quality Rolling shutter fire door The door of Henan refuge room 3. The adhesive shall meet the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 4. Dimensional deviation: the height of the door leaf shall not exceed 2mm, the width of the door leaf shall not exceed 2mm, the thickness of the door leaf shall be between - 1mm and+2mm, the height of the clipping opening in the door frame shall not exceed 3mm, the width of the clipping opening in the door frame shall not exceed 2mm, and the width of the side wall of the door frame shall not exceed 2mm. 5. Geometric tolerance: the length difference between the two diagonals of the door leaf shall be less than or equal to 3mm, The distortion of the door leaf shall be less than or equal to 5mm, the curvature of the door leaf in the width direction shall be less than 2%, the curvature of the door leaf in the height direction shall be less than 2%, and the length difference between the two diagonals of the inner cutting opening shall be less than or equal to 3mm. 6. Fit tolerance: the overlap size between Manshan and the door frame is less than or equal to 12mm, the fit clearance between the door leaf and the door frame at the hinge side shall not be greater than the size tolerance specified in the design drawing, and the fit clearance between the door leaf and the door frame at the lock side shall not be greater than the size tolerance specified in the design drawing. Rolling shutter fire door Manufacturer The clearance between the door leaf and the upper frame shall be less than or equal to 3mm, the clearance between the double leaf and multi leaf door leaves shall be less than or equal to 3mm, the clearance between the door leaf and the lower frame or the ground shall be less than or equal to 9mm, the clearance between the binding surface of the door leaf and the side of the door frame with hinges shall be less than or equal to 3mm, the clearance between the binding surface of the door leaf and the side of the door frame with locks shall be less than or equal to 3mm, and the clearance between the binding surface of the door leaf and the upper frame of the door frame shall be less than or equal to 3mm, The plane height difference between the door frame and the door leaf is less than or equal to 1mm.

What are the requirements for the width of the door of Henan Refuge Room? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings: for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be set with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The [] of the room should adopt the Z-grade fire door, and the fire resistance integrity of the outer window should not be less than 1.00h. high quality Rolling shutter fire door The total net width of the door, emergency exit, evacuation walkway and evacuation staircase of the residential building with the door of Henan refuge room shall be determined by calculation, and the net width of the door, emergency exit and evacuation staircase shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. Rolling shutter fire door Manufacturer The relevant requirements of the Code for Fire Protection Design of Buildings stipulate that: 1. For the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 evacuation [] or emergency exits in buildings of Class I and II fire resistance rating, the straight-line distance from any indoor point to the evacuation door] or emergency exit shall not be more than 30 m.

The use and maintenance of henan fire rolling shutter door henan fire rolling shutter door is a very important fire protection facility for fire compartment and fire partition in public places. high quality Rolling shutter fire door It is also a fire protection product with comprehensive mechanical and electrical performance, so the installed fire shutter should always be kept in normal condition. During the use of Henan fire rolling shutter door, special equipment shall be used and kept by special personnel, and have certain basic knowledge of electricians and machinery. During the operation of fire rolling shutter door, the operator shall not leave the operation site without authorization, and shall pay close attention to the opening and closing conditions and implementation conditions. No one is allowed to stand or walk under the shutter when opening and closing. To prevent travel switch failure, roller shutter stuck, motor blocked and other accidents. The steel fire shutter of fire compartment and fire partition is not frequently used at ordinary times. In case of fire in the area, the shutter should be put into use effectively. The automatic control fire shutter with linkage control and central control center control must be carried out according to a set of control command procedures. Fire rolling shutter door.jpg The basic function of Henan fire rolling shutter door is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. This product is very good at preventing ultraviolet rays. The temperature is relatively high in summer, and one of these products can prevent ultraviolet rays. The ultraviolet radiation is destructive to human skin, so it seems very important. This product has helped me. This product has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. Rolling shutter fire door Manufacturer We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

What are the requirements for the opening direction of the door of Henan Refuge Room? Fire doors play an important role in life. The opening direction of fire doors is very important. The Code for Fire Protection Design of Tall Buildings has clearly stipulated that the stairwell should be opened in the direction of evacuation, such as the stairwell should be opened in the direction of the staircase lobby, so as to facilitate the evacuation of people. high quality Rolling shutter fire door In addition, the front room is generally a place of refuge and an evacuation passageway. In case of a fire, positive pressure air supply is required. If it is not installed in the above opening direction, the air pressure may open the fire door, causing fire and smoke leakage. 4. Classification 4.1 According to the number of door leaves, there are steel single fire door and steel double fire door. 4.2 According to the door leaf structure, there are steel fire door with glass lining, steel fire door without glass lining, steel fire door with bright window and steel fire door without bright window. Rolling shutter fire door Manufacturer According to the fire resistance limit, there are Class A fire doors, Class B fire doors and Class C fire doors.

Placement requirements, maintenance methods and precautions of Henan fire door at ordinary times Maintenance methods and precautions of fire door at ordinary times. high quality Rolling shutter fire door When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 2. Do not pull off the fireproof seal, or it will lose its function in case of fire. Henan fireproof doors and windows cannot be left open for a long time, which will damage the door closer and make it lose its function. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 3. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 4. Henan fireproof doors and windows shall be protected from outdoor sunshine for a long time to prevent the fireproof door from being heated. Rolling shutter fire door Manufacturer It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. After splashing with water, wipe it with dry cloth to avoid local expansion. The fire door closer must be replaced in case of oil leakage.