What are the functions of the doors of Henan Refuge Room? With the rapid progress of society, in order to improve our fire awareness in life, Henan Refuge Room doors have been used. high quality fire-proof wooden door So, what are the advantages of this product? Next, let's introduce the door manufacturer of Henan Refuge Room to you. 1、 The basic function of fire shutter is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. 2、 This product has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. fire-proof wooden door direct deal We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

The type, type, specification, size, opening direction, device position and anti-corrosion solution of Henan fire rolling shutter door shall meet the design requirements. high quality fire-proof wooden door The accessories of the roller shutter door are complete, the position is accurate, the device is stable, and the function should meet the use requirements and various performance requirements of Luoyang roller shutter door. The rolling shutter must be firmly installed, and the number, position, embedding method and connection method with the frame of the embedded parts must meet the design requirements. The appearance of the rolling shutter door shall be clean without scratches and bruises. Eight advantages of Henan fireproof rolling shutter door: energy saving: two key technologies realize energy saving. First of all, the door opening design and double door interlock greatly shorten the door opening cycle. For clean rooms, the shortening of the door opening cycle can reduce the indoor air loss and improve the insulation capacity. In addition, there are double rows of encrypted sealing brushes inside the column of the fast door, and the pvc base card design makes installation and replacement convenient. Cost saving: The fast door is equipped with a LCD display, which will prompt when the door fails to operate, and the code or Chinese display will be displayed. This can avoid costly downtime and time-consuming technical maintenance, which greatly saves costs. Complete types: fast doors include explosion-proof fast doors, wind resistant fast doors, zippered fast doors (also called anti-collision automatic reset fast doors). Rich functions: Henan explosion-proof rolling shutter door can be linked with the air shower room, goods elevator, mechanical arm, assembly line, etc. High efficiency: according to the actual situation and requirements of customers on the site, provide a variety of control switches to improve the efficiency of daily operation. There are radar induction door opening, rope pulling door opening, geomagnetic induction door opening, remote control door opening, card swiping door access control door opening and other door opening methods. Safety: The bottom of Henan fast rolling shutter door is air tight and soft, and the door curtain is soft. There are safety photoelectric devices on both sides of the track. When there are people or obstacles under the door body, the door body will not fall, to ensure that people will not be touched by the door body. fire-proof wooden door direct deal After sales guarantee: the control system of the fast door can timely identify the fault of Henan fast rolling shutter door, and then solve the problem in time. Yuou Door&Window Technology has a special after-sales maintenance department, which can respond within 12 hours if there is a fault.

The role of Henan fire doors in fire protection We often see on the ground of some large or local places that no one is allowed to stand under the fire facilities or shelves are placed. high quality fire-proof wooden door Then, the primary use of assembling fire doors is that if a fire occurs in a certain place, the rolling shutter door can stop the extension of the fire when it is put down. Usually, the fire doors in such large buildings have automatic central control systems. Once a fire occurs, you can automatically implement a series of behaviors, and the fire doors will automatically lower the fire. The following is the employment process of the automatic control system of the fire door. When a fire occurs, the smoke sensor installed on the roof receives the flag of the smoke and alarms to the central control system. After identification, the control system of the fire center connects the power supply of the fire door in the fire alarm location area, so that the fire shutter in the fire area will fall to the ground at the required rate. When the roller shutter passes to a position about 1.5 meters above the ground, stop the activity, so as to facilitate the evacuation and evacuation of employees on site. After the associated employees withdraw together, the fire door will continue to go down until it is closed. The descending rate of the fire door and the time of stay during the period can be adjusted according to the number of employees. fire-proof wooden door direct deal It is not only such places that are equipped with fire doors, but also in some staircases, corridors and other places. Since fire is rarely generated and some fire prevention settings are easy to use, the conditions must be inspected regularly by dedicated staff.

Henan fire door refers to the door that can meet the requirements of fire resistance stability, integrity and heat insulation within a certain period of time. high quality fire-proof wooden door It is a fire compartment with certain fire resistance, which is located in fire compartment, evacuation staircase, vertical shaft, etc. In addition to the function of ordinary doors, fire doors can also prevent the spread of fire and smoke, which can prevent the spread of fire within a certain period of time and ensure the evacuation of people. Henan fire doors are certified by the Ministry of Economic Affairs of the Ministry of Fire Protection. According to the new version of the standard for fire doors GB_12955-2008 implemented on January 1, 2009, those who pass the fire resistance test of fire doors and have obtained the registration certificate and authorized logo issued by the Bureau of Standards and Inspection of the Ministry of Economic Affairs are called fire doors. fire-proof wooden door direct deal The fire door defined in the American NFPA and IBC codes is "any combination of fire door leaves, door frames, hardware and other accessories that can jointly provide a certain degree of fire protection at the opening."

What is the difference between the normally open and normally closed fire doors of Henan fire doors? The differences between the normally open and normally closed fire doors are as follows: 1. Different meanings. The normally open fire doors are usually open, and they are automatically closed by the control system only in case of fire. It is generally used in the passage or corridor of public places. high quality fire-proof wooden door Normally closed fire doors are closed under normal conditions and in case of fire, and need to be pushed open when someone walks around, so as to prevent smoke and fire and prevent the spread of fire. 2. The price is different, and the price of the normally open fire door is higher, and the system is strong. The price of normally closed fire doors is relatively low. Henan fireproof doors and windows 3. The composition is different. The normally open fireproof door consists of door leaf, door frame, door closer, sealing strip, release switch and other parts. The normally closed fireproof door is equipped with sequencer in addition to the above parts. 4. The control mode is different. The normally open fire door is controlled by the fire door release switch. The normally closed fire door does not need to be set with electric automatic control. It is mainly closed by the door closer and sequencer, that is, mechanical. Precautions for Henan fire door fire door 1. The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2. The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3. No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. Henan fireproof doors and windows 4. When installing the fireproof door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted, and then it can be connected and anchored. 5. The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. fire-proof wooden door direct deal Henan fireproof doors and windows 6. Door closers must be installed on fireproof doors, and sequencers must be installed on opposite doors. 7. The handle, fire lock and other hardware accessories on the fire door must be complete. 8. It is required that the clearance from the ground plane shall not be greater than 5mm.

Henan fire door is an important part of fire fighting equipment. Fire door is an important part of fire fighting equipment and an important part of social fire prevention. Therefore, the quality and use of fire door is the key to the success of fire prevention. high quality fire-proof wooden door The fire resistance limit of Class C fireproof door is 0.6h) 1. The inspection door on the wall of equipment tube well, ventilation duct and garbage duct shall be Class C fireproof door. 2. The front door of the garbage way shall be Class C fireproof door. 3. When the cable shaft and pipe shaft are set in the front room of the smoke proof staircase and the shared front room, the inspection door on the shaft wall shall be Class C fireproof door. 4. The door connecting the substation and distribution substation should be Class C fireproof door. The door directly leading to the outdoor of the substation shall be Class C fireproof door. 5. The cable well and pipe well shall be separated from each other every 2~3 floors by incombustible materials equivalent to the fire resistance limit of the floor. The inspection door on the shaft wall shall be Class C fire door. 6. The garbage hopper shall be made of incombustible and corrosion-resistant materials and can be closed and sealed by itself; Garbage hoppers of high-rise buildings and super high-rise buildings shall be located in the front room of the garbage chute, which shall be equipped with Class C fireproof doors. 7. The telecommunication room shall adopt outward opening Class C fireproof door with a width of more than 0.7m. 8. The oxygen busbar room with the oxygen delivery capacity not exceeding 60m3/h can be set in the user's workshop with the fire resistance rating not lower than Grade III and close to the external wall. The wall with the height of 2.5m and the fire resistance rating not lower than 1.5h and the Grade C fire door should be used to separate it from other parts of the workshop. 9. The partition wall of the collection warehouse and exhibition room shall be non combustible. The compartments in the fire compartment shall be separated by partition walls with a fire resistance rating of not less than 3h and Class B fire doors. The enclosure structure of closed shaft shall be non combustible and Class C fireproof door. 10. The fire resistance limit of partition walls between production rooms with explosion risk shall not be less than 1.5h. fire-proof wooden door direct deal The door is Class C fireproof door. 11. When the oxygen generation station building or liquid oxygen gasification station building and oxygen filling station building are arranged in the same building, the noncombustible partition wall with a fire resistance rating of not less than 1.5h and Class C fire door shall be used, and they shall be connected through the walkway. 12. The doors on the partition walls between the oxygen compressor room and the bottle filling room, as well as the purification room, the oxygen storage bag room, the oxygen storage tank room, the liquid oxygen storage tank room and other rooms shall be Class C fireproof doors.