The use and maintenance of henan fire rolling shutter door henan fire rolling shutter door is a very important fire protection facility for fire compartment and fire partition in public places. major Class A fireproof door It is also a fire protection product with comprehensive mechanical and electrical performance, so the installed fire shutter should always be kept in normal condition. During the use of Henan fire rolling shutter door, special equipment shall be used and kept by special personnel, and have certain basic knowledge of electricians and machinery. During the operation of fire rolling shutter door, the operator shall not leave the operation site without authorization, and shall pay close attention to the opening and closing conditions and implementation conditions. No one is allowed to stand or walk under the shutter when opening and closing. To prevent travel switch failure, roller shutter stuck, motor blocked and other accidents. The steel fire shutter of fire compartment and fire partition is not frequently used at ordinary times. In case of fire in the area, the shutter should be put into use effectively. The automatic control fire shutter with linkage control and central control center control must be carried out according to a set of control command procedures. Fire rolling shutter door.jpg The basic function of Henan fire rolling shutter door is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. This product is very good at preventing ultraviolet rays. The temperature is relatively high in summer, and one of these products can prevent ultraviolet rays. The ultraviolet radiation is destructive to human skin, so it seems very important. This product has helped me. This product has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. Class A fireproof door Price We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

What are the functions of the doors of Henan Refuge Room? With the rapid progress of society, in order to improve our fire awareness in life, Henan Refuge Room doors have been used. major Class A fireproof door So, what are the advantages of this product? Next, let's introduce the door manufacturer of Henan Refuge Room to you. 1、 The basic function of fire shutter is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. 2、 This product has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. Class A fireproof door Price We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

Relevant requirements for fire protection of the door of Henan Refuge Room What kind of products are qualified when the door of Henan Refuge Room passes the fire protection? Here are some examples: 1. Filling materials: the filling materials must meet the requirements of combustion performance A1 specified in GB8624-2006. At the same time, it meets the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 2. Material thickness: door leaf material shall be no less than 0.8mm, door panel material shall be no less than 0.8mm, door frame plate shall be no less than 1.2mm, hinge plate shall be no less than 3.0mm, reinforcement without screw holes shall be no less than 1.2mm, and reinforcement with screw holes shall be no less than 3.00mm. major Class A fireproof door The door of Henan refuge room 3. The adhesive shall meet the requirements of smoke toxicity hazard classification ZA2 specified in GB/T20285-2006. 4. Dimensional deviation: the height of the door leaf shall not exceed 2mm, the width of the door leaf shall not exceed 2mm, the thickness of the door leaf shall be between - 1mm and+2mm, the height of the clipping opening in the door frame shall not exceed 3mm, the width of the clipping opening in the door frame shall not exceed 2mm, and the width of the side wall of the door frame shall not exceed 2mm. 5. Geometric tolerance: the length difference between the two diagonals of the door leaf shall be less than or equal to 3mm, The distortion of the door leaf shall be less than or equal to 5mm, the curvature of the door leaf in the width direction shall be less than 2%, the curvature of the door leaf in the height direction shall be less than 2%, and the length difference between the two diagonals of the inner cutting opening shall be less than or equal to 3mm. 6. Fit tolerance: the overlap size between Manshan and the door frame is less than or equal to 12mm, the fit clearance between the door leaf and the door frame at the hinge side shall not be greater than the size tolerance specified in the design drawing, and the fit clearance between the door leaf and the door frame at the lock side shall not be greater than the size tolerance specified in the design drawing. Class A fireproof door Price The clearance between the door leaf and the upper frame shall be less than or equal to 3mm, the clearance between the double leaf and multi leaf door leaves shall be less than or equal to 3mm, the clearance between the door leaf and the lower frame or the ground shall be less than or equal to 9mm, the clearance between the binding surface of the door leaf and the side of the door frame with hinges shall be less than or equal to 3mm, the clearance between the binding surface of the door leaf and the side of the door frame with locks shall be less than or equal to 3mm, and the clearance between the binding surface of the door leaf and the upper frame of the door frame shall be less than or equal to 3mm, The plane height difference between the door frame and the door leaf is less than or equal to 1mm.

A brief talk on the problems encountered in the fire acceptance of Henan fire rolling shutter door 1. The curtain plate coating falls off and rusts, and the curtain plate has obvious pressure pits, concave convex, and penetrating holes. major Class A fireproof door The rolling shutter is a complete fire protection product. If the shutter has problems, it will directly affect the fire resistance limit index of the rolling shutter. 2. The guide rail is deformed and the curtain board is stuck or falls unevenly. The fireproof rolling shutter door generally moves along the guide rail. If the guide rail is twisted or broken, the rolling shutter door will not be able to move to the specified position, which will not achieve the effect of fire separation. 3. On the roller shutter, the lower limit fails or the limit line is wrongly connected. Class A fireproof door Price This often happens on the fire roller shutter of the atrium. Because the fire roller shutter of the atrium is sometimes installed outside the walkway of the upper floor, there is no floor under the roller shutter to close it, and a large gap is leaked, so the fire separation of the upper and lower floors cannot be reached.