The installation and installation of Henan fireproof rolling shutter door requires that the fireproof rolling shutter door is widely used in shopping malls, shopping malls and underground garages, but the specific installation steps should not mention laymen. major Class A fireproof window Even the fireproof rolling shutter door can not be explained in detail. The following is a detailed description of the installation of Henan fireproof rolling shutter door step by step: step 1: install the guide rail. 1. Determine the installation position of the guide rail on both sides of the fireproof rolling shutter door, set out the guide rail reference line with hammer line, and set out the cross line of the fixing bolt of the guide rail connector. The guide rail is not less than 75cm above the ceiling. 2. Punch the holes for fixing expansion bolts of connectors on the wall column with a percussion drill. The spacing between connectors shall not be more than 600mm, and both ends shall be 100mm away from the guide rail opening. Fix several connecting pieces up and down first, stick the guide rail, correct its verticality and spot weld it, and then repeat the verticality of the guide rail after fixing the guide rail. The verticality of each meter shall not exceed 5mm, and the verticality of the whole length shall not exceed 20mm. The depth of the composite curtain embedded in the guide rail (see GBl4102-2005). 3. Install the rest of the connecting pieces. Spot welding shall be adopted between the connecting piece and the guide rail. The spot welding points between each connecting piece and a guide rail shall not be less than 5 points, and the width of the spot welding shall not be less than 5mm. The welding point shall never be penetrated. Class A fireproof window direct deal Stainless steel welding rod shall be used when stainless steel guide rail is used.

 Xinyang professional Grade A fireproof window manufacturer direct sales

The advantages and disadvantages of the products of Henan fire rolling shutter manufacturers The fire rolling shutter is usually located at the poor entrance of the building, which plays a role in fire prevention, heat insulation and smoke dispersion. The fireproof rolling shutter door is a useful time to isolate the fire source when a fire occurs and provide a useful escape for employees. major Class A fireproof window However, the inferior fire rolling shutter door will not only not intercept the fire source, but also increase the fire. Therefore, the advantages and disadvantages of the fire rolling shutter door are also quite important. Henan fire rolling shutter door The rolling shutter door will stop landing when landing to the required height, which is to avoid people who have not had time to escape being trapped inside the rolling shutter door. Class A fireproof window direct deal If the inferior rolling shutter doors were all lowered, the surviving victims would be trapped inside and become unnecessary casualties. Recommended reading: The fire hour and temperature resistance limit of some fire rolling shutter doors are strictly defined in the fire rolling shutter door specification. Therefore, excellent guaranteed fire rolling shutter doors must be used when adopting and purchasing rolling shutter doors.

 Xinyang professional Grade A fireproof window manufacturer direct sales

What are the requirements for the width of the door of Henan Refuge Room? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings: for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be set with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The [] of the room should adopt the Z-grade fire door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Class A fireproof window The total net width of the door, emergency exit, evacuation walkway and evacuation staircase of the residential building with the door of Henan refuge room shall be determined by calculation, and the net width of the door, emergency exit and evacuation staircase shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. Class A fireproof window direct deal The relevant requirements of the Code for Fire Protection Design of Buildings stipulate that: 1. For the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 evacuation [] or emergency exits in buildings of Class I and II fire resistance rating, the straight-line distance from any indoor point to the evacuation door] or emergency exit shall not be more than 30 m.

 Xinyang professional Grade A fireproof window manufacturer direct sales

Control Procedure for Internal Quality Management System of Henan Refuge Room Door Manufacturer 1. Purpose To conduct regular internal quality audits to verify the quality activities and related results. Stone composite procedure documents: CCCF-HZFH-02 (A/O) Rules for the Implementation of Compulsory Product Certification, Fire Protection Products, Fire Resistant Components of Buildings and other quality documents, and take corrective measures in a timely manner, So as to make the quality management system operate effectively and ensure that the product consistency meets the requirements of relevant approval rules. 2. The scope is applicable to the audit of our internal quality management system. 3. Responsibilities: The quality director shall lead the internal quality audit work, and the audit team leader shall organize the internal quality audit work under the centralized management of the office, with the cooperation of each department. Henan Refuge Room 4. Procedure (1) Audit frequency The internal quality management system of each department shall be audited at least once a year according to the following procedures. major Class A fireproof window In case of major quality accident or other special reasons, the quality director shall decide to conduct targeted additional audit. (2) The Audit Planning Office shall propose the "Annual Internal Quality Management System Audit Plan" every year according to the actual situation and importance of audit activities, which shall be approved and implemented by the quality director. (3) Auditors The auditors shall have the qualification of internal auditors and have no direct responsibility for the audited activities, and shall be appointed by the General Manager. For the temporary additional audit, the quality director shall specify the audit team leader and auditors. (4) Before each audit, the office shall prepare the "audit schedule plan", which shall be approved by the person in charge of quality. The audit team leader reviews the documents and assigns tasks to the auditors, who prepare the audit checklist. (5) Audited department and audit schedule; Purpose, scope and basis of audit; Audit content and specific time arrangement; Division of auditors, etc. Class A fireproof window direct deal The audit schedule shall be sent by the audit team leader to the audited department one week in advance. After receiving the audit schedule, the audited department can notify the audit team leader in advance if there is any objection. After negotiation, it can make appropriate adjustments.

 Xinyang professional Grade A fireproof window manufacturer direct sales

What are the requirements for the opening direction of the door of Henan Refuge Room? Fire doors play an important role in life. The opening direction of fire doors is very important. The Code for Fire Protection Design of Tall Buildings has clearly stipulated that the stairwell should be opened in the direction of evacuation, such as the stairwell should be opened in the direction of the staircase lobby, so as to facilitate the evacuation of people. major Class A fireproof window In addition, the front room is generally a place of refuge and an evacuation passageway. In case of a fire, positive pressure air supply is required. If it is not installed in the above opening direction, the air pressure may open the fire door, causing fire and smoke leakage. 4. Classification 4.1 According to the number of door leaves, there are steel single fire door and steel double fire door. 4.2 According to the door leaf structure, there are steel fire door with glass lining, steel fire door without glass lining, steel fire door with bright window and steel fire door without bright window. Class A fireproof window direct deal According to the fire resistance limit, there are Class A fire doors, Class B fire doors and Class C fire doors.