Can the door of Henan Refuge Room be removed? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings, for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be equipped with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The door of the room should be Class B fireproof door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Steel Grade A fireproof door The total net width of each door, emergency exit, evacuation walkway and evacuation staircase of the residential building shall be determined by calculation, and the net width of the door and emergency exit shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation outer door shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. The relevant requirements of the Code for Fire Protection Design of Henan Refuge Room Door Buildings stipulate that: 1. Evacuation in buildings with Class I and II fire resistance rating] or the linear distance from any point in the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 emergency exits to the nearest evacuation] or the emergency exit shall not be more than 30m. 2. When the evacuation door] cannot directly connect to the outdoor ground or the evacuation staircase, an evacuation corridor with a length of no more than 10m shall be used to connect to the nearest emergency exit. Steel Grade A fireproof door Manufacturer When the place is equipped with automatic sprinkler system, the safe evacuation distance from any indoor point to the near emergency exit can be increased by 25%.

Henan fireproof rolling shutter door maintenance common faults and treatment methods The fireproof rolling shutter door is constantly applied to large supermarkets, shopping malls, underground garages, workshops and other crowded places. It is inevitable that there will be some small problems that need to be solved. I summarize a few points for your reference. 1、 The fire shutter door does not act: first, check the power supply to see if the power supply air switch of the fire shutter door has power. If there is no power, check the power supply. If there is power, the power indicator of the roller shutter control box should be green at this time. major Steel Grade A fireproof door If the indicator light is not on, then we should check whether the transformer in the control box (the resistance of the transformer is 270 ohms) is burned out. If the power indicator flashes green, it indicates that the power supply may be out of phase. If the power supply is not out of phase, it may be that the standby power board of the control box is burned out; It is also possible that both the power board and the standby power board are burned out. 2、 Henan fire shutter door power supply air switch cannot be pushed up: when delivering the gate, the air switch cannot be pushed up, first check whether there is a problem with the standby board, and the resistance of the output line of the standby board is about 300 ohms. In case of open circuit or short circuit, check whether the motor brake is burnt or whether the spare board is burnt. 3、 The operation button does not work properly: you should first press the Stop key, then press the Reset key, and then press the Up and Down keys. 4、 The indicator lights of the power control box or button panel are all on: at this time, first check whether there is a short circuit in the button line or a button may be pressed to death. If the above phenomenon does not exist, it may be that the chip on the power main board is broken, and then replace the chip. Steel Grade A fireproof door Manufacturer Pay attention to wearing the clothes in reverse (that is, the opening faces the opening).

Henan fire rolling shutter door is generally installed in the place determined by the process. In addition to the firewall, the fire rolling shutter door should be installed in the two fire compartments where there is no firewall. It is generally located at the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Divide the fire compartment and control the fire wall and the door on the fire partition in the building area of the compartment. When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (3) Code (such as GB50045-95 Code for Fire Protection Design of High rise Civil Buildings) or partition door with special requirements for fire and smoke prevention. major Steel Grade A fireproof door For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. Steel Grade A fireproof door Manufacturer The limited area of Henan fire shutter door special grade fire shutter In the use of special grade fire shutter, because it is mainly used in the rapid formation of fire separation areas, and is mostly set in applications with large space, as a visible fire separation device, generally in the production of fire shutter, fire shutter will be painted with a more striking color, It can not only make the fireproof rolling shutter have a better decorative effect after being folded, but also can remind people of the escape route in fire accidents through eye-catching and penetrating colors in the fire compartment, so as to buy time for effective escape.

The advantages and disadvantages of the products of Henan fire rolling shutter manufacturers The fire rolling shutter is usually located at the poor entrance of the building, which plays a role in fire prevention, heat insulation and smoke dispersion. The fireproof rolling shutter door is a useful time to isolate the fire source when a fire occurs and provide a useful escape for employees. major Steel Grade A fireproof door However, the inferior fire rolling shutter door will not only not intercept the fire source, but also increase the fire. Therefore, the advantages and disadvantages of the fire rolling shutter door are also quite important. Henan fire rolling shutter door The rolling shutter door will stop landing when landing to the required height, which is to avoid people who have not had time to escape being trapped inside the rolling shutter door. Steel Grade A fireproof door Manufacturer If the inferior rolling shutter doors were all lowered, the surviving victims would be trapped inside and become unnecessary casualties. Recommended reading: The fire hour and temperature resistance limit of some fire rolling shutter doors are strictly defined in the fire rolling shutter door specification. Therefore, excellent guaranteed fire rolling shutter doors must be used when adopting and purchasing rolling shutter doors.

How to choose Henan fire doors with good quality and low price as ordinary home decoration users, how to use fire doors with fire prevention characteristics and anti-theft talents, and perhaps in line with the decoration style of the hall, and to reach higher quality, through the appropriate price, may be won in the estimation. They are all manufacturers that need to use and meet the national quality standards. Only when the brand quality is excellent, can the material of the fire door body reach a high strength and durable scale, or reach a high strength and airtight condition while having fire prevention characteristics, or reach a difficult deformation quality under tropical burns, so as to eliminate the need for fire prevention. major Steel Grade A fireproof door In terms of materials, it is also advisable to use wood materials and steel materials, and fire doors made of pure materials. The price of different materials is different, and it is possible to reach the national standard with both fire prevention talents. Therefore, only manufacturers with strong brands can reach a comfortable level in terms of quality conditions of fire doors, and may use fire doors with good quality and low price. Steel Grade A fireproof door Manufacturer The fire door should be protected regularly. In addition to handling the dust to send some bearing parts for oiling, it should also be opened at regular intervals to ensure its normal use.

Whether Henan fireproof door should be made of wood or steel? I think that many people's understanding of wooden fireproof door is still in the process of questioning whether wooden fireproof door can be safe against fire. There is no need to talk about whether steel fireproof door or wooden fireproof door is better. Usually people subconsciously think that steel fireproof door is better than wooden fireproof door. major Steel Grade A fireproof door According to the Code for Construction Quality Acceptance of Decoration Engineering? GB50210-2001? As far as wood fire doors are concerned, they belong to special doors. Therefore, wood fire doors can not only provide fire safety, but also are widely used in various industrial buildings and some public buildings because of their elegant appearance design, convenient installation and good decorative arts. But it is also beautiful and generous. In the final analysis, what about the wooden fire door with fire safety characteristics? Which is better, steel fire door or wood fire door? Let's have a look at their advantages and differences: wooden fireproof doors refer to those doors whose fire resistance rating exceeds the requirements of GB50045-95? Code for Fire Protection Design of High rise Residential Industrial Buildings with wood or wood handicrafts as door frames, door frame framework drawings, door frame control panels. Steel Grade A fireproof door Manufacturer Wooden fireproof doors are divided into full panel and half glass series products, as well as specifications and models of single and double leaves.