Why is Henan fire rolling shutter an indispensable facility? Why is fire rolling shutter an indispensable facility. major Rolling shutter fire door The types of fire rolling shutter doors in Henan mainly include composite steel fire rolling shutter (fire and smoke prevention), inorganic super grade fire rolling shutter (double track double shutter), steel composite water spray steam fog fire rolling shutter, steel composite lateral fire rolling shutter, steel composite horizontal fire rolling shutter, inorganic super grade folding fire rolling shutter and fire rolling shutter with various doors. The fireproof rolling shutter door, as well as the firewall, functions as a horizontal fireproof partition. It is composed of 13 parts, such as shutter, base plate, guide rail, support, reel, box, control box, door rolling machine, limiter, door header, manual quick release switch device, button switch and safety device, and is generally installed at the position that is not convenient for firewall separation. For example, open elevator halls, escalators, wide business halls of department stores, exhibition halls of exhibition buildings, and parts of buildings with large openings that cannot use fireproof doors and windows. Fire resisting rolling shutter door has been widely used in building engineering to make fire separation. Rolling shutter fire door direct deal Henan fireproof rolling shutter door is an indispensable fire prevention facility in modern high-rise buildings. In addition to the function of ordinary door, the fireproof door has the special functions of fire prevention, smoke separation, suppression of fire spread, and protection of personnel evacuation. It is widely used in high-rise buildings, large shopping malls and other crowded places.

Maintenance methods and precautions of Henan fireproof door Maintenance methods and precautions of Henan fireproof door: 1. Door leaf and door frame shall be placed horizontally and stacked indoors with backing plates, and the frame and door leaf shall be stacked separately. 2. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 3. It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 4. Try to avoid outdoor sunshine for a long time to prevent the fire door from being heated. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. major Rolling shutter fire door After splashing with water, wipe it with dry cloth to avoid local expansion. 6. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. 7. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. 8. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 9. Do not support the door for a long time without closing it, which will damage the door closer and make it lose its function. 10. Do not pull off the fireproof seal, or it will lose its function in case of fire. 11. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 12. When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. 13. The fire door closer must be replaced in case of oil leakage. Rolling shutter fire door direct deal Then, the Henan Fireproof Doors and Windows Editor summarized the above contents into the following points, and you must remember! Do not always open: it is prohibited to manually keep the normally closed fire doors set on the evacuation walkway, the front room of the smoke proof staircase or the shared front room open during the use process to become "normally open" fire doors. In case of a fire, such "normally open" fire doors can not prevent smoke and fire; Regular inspection: frequently check the integrity of the fire door, check whether the door closer and sequencer are in good use, whether the fire door can be closed automatically in order, and whether the screws on the hinge and hinge are loose. If damaged, immediately organize maintenance; Decoration: one-sided pursuit of decoration effect, canceling the fire door frame and setting only the door pocket made of ordinary wood, replacing the original frame of the door leaf with other materials, and adding decorative surface layer in a large range, thus damaging the fire retardant coating and failing to achieve fire retardant effect; Regular test: the normally open fire door shall be tested regularly to check whether its self closing control system, door closer, sequencer, release switch and other aspects are easy to use, whether it can effectively perform the self closing function in case of fire, and at the same time, it is necessary to resolutely prevent the random stacking of articles near the normally open fire door.

The type, type, specification, size, opening direction, device position and anti-corrosion solution of Henan fire rolling shutter door shall meet the design requirements. major Rolling shutter fire door The accessories of the roller shutter door are complete, the position is accurate, the device is stable, and the function should meet the use requirements and various performance requirements of Luoyang roller shutter door. The rolling shutter must be firmly installed, and the number, position, embedding method and connection method with the frame of the embedded parts must meet the design requirements. The appearance of the rolling shutter door shall be clean without scratches and bruises. Eight advantages of Henan fireproof rolling shutter door: energy saving: two key technologies realize energy saving. First of all, the door opening design and double door interlock greatly shorten the door opening cycle. For clean rooms, the shortening of the door opening cycle can reduce the indoor air loss and improve the insulation capacity. In addition, there are double rows of encrypted sealing brushes inside the column of the fast door, and the pvc base card design makes installation and replacement convenient. Cost saving: The fast door is equipped with a LCD display, which will prompt when the door fails to operate, and the code or Chinese display will be displayed. This can avoid costly downtime and time-consuming technical maintenance, which greatly saves costs. Complete types: fast doors include explosion-proof fast doors, wind resistant fast doors, zippered fast doors (also called anti-collision automatic reset fast doors). Rich functions: Henan explosion-proof rolling shutter door can be linked with the air shower room, goods elevator, mechanical arm, assembly line, etc. High efficiency: according to the actual situation and requirements of customers on the site, provide a variety of control switches to improve the efficiency of daily operation. There are radar induction door opening, rope pulling door opening, geomagnetic induction door opening, remote control door opening, card swiping door access control door opening and other door opening methods. Safety: The bottom of Henan fast rolling shutter door is air tight and soft, and the door curtain is soft. There are safety photoelectric devices on both sides of the track. When there are people or obstacles under the door body, the door body will not fall, to ensure that people will not be touched by the door body. Rolling shutter fire door direct deal After sales guarantee: the control system of the fast door can timely identify the fault of Henan fast rolling shutter door, and then solve the problem in time. Yuou Door&Window Technology has a special after-sales maintenance department, which can respond within 12 hours if there is a fault.

What is the standard of Henan refuge door? Requirements for fire protection structure: 1) The floor of the evacuation floor must be cast-in-place reinforced concrete floor, and the fire resistance must be 2.00h or higher. major Rolling shutter fire door It is necessary to provide insulation on the floor. The fire resistance of the walls around the evacuation floor and the bulkheads in the evacuation floor shall not be less than 3.00h, and the bulkhead doors must be fire doors. Henan refuge bay door 2. As the equipment floor: 1) Gather various equipment and pipeline shafts into compartments. The flammable and combustible liquid or gas pipeline shall be located in the center, and the equipment pipeline area shall be separated from the fire prevention area and evacuation area. The fire prevention limit of the firewall is 3.00h or more. 2) The pipe shaft and machine room must be separated from the evacuation area, and the fire partition with a fire limit of 2.00h or more shall be used. Pipeline wells and equipment doors shall not be opened directly to the evacuation area. Rolling shutter fire door direct deal If you really need to enter the evacuation place, the distance from the entrance to the evacuation place must be at least 5m, and fire doors must be used in the evacuation room.

What is the difference between the normally open and normally closed fire doors of Henan fire doors? The differences between the normally open and normally closed fire doors are as follows: 1. Different meanings. The normally open fire doors are usually open, and they are automatically closed by the control system only in case of fire. It is generally used in the passage or corridor of public places. major Rolling shutter fire door Normally closed fire doors are closed under normal conditions and in case of fire, and need to be pushed open when someone walks around, so as to prevent smoke and fire and prevent the spread of fire. 2. The price is different, and the price of the normally open fire door is higher, and the system is strong. The price of normally closed fire doors is relatively low. Henan fireproof doors and windows 3. The composition is different. The normally open fireproof door consists of door leaf, door frame, door closer, sealing strip, release switch and other parts. The normally closed fireproof door is equipped with sequencer in addition to the above parts. 4. The control mode is different. The normally open fire door is controlled by the fire door release switch. The normally closed fire door does not need to be set with electric automatic control. It is mainly closed by the door closer and sequencer, that is, mechanical. Precautions for Henan fire door fire door 1. The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2. The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3. No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. Henan fireproof doors and windows 4. When installing the fireproof door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted, and then it can be connected and anchored. 5. The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. Rolling shutter fire door direct deal Henan fireproof doors and windows 6. Door closers must be installed on fireproof doors, and sequencers must be installed on opposite doors. 7. The handle, fire lock and other hardware accessories on the fire door must be complete. 8. It is required that the clearance from the ground plane shall not be greater than 5mm.