上海龙凤shlf1314足浴

Hello! Welcome to the website of Henan Rui'andun Door Industry Co., Ltd!

 Henan fireproof door

contact us

Tel.: 0371-85127888

Fax: 0371-62495556

Mobile: 17788121396

Email: [email protected]

website: www.00151.cn

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City

Chongqing professional refuge door manufacturer

Your current location: home page > Hot information

Chongqing professional refuge door manufacturer

2023-09-07
 Chongqing professional refuge door manufacturer

Maintenance and cultivation of Henan fire rolling shutter All fire rolling shutters should be checked and tested once a week. The test content includes: fire rolling shutter escape function test. major Refuge bay door After the fire roller shutter is in the linkage state and drops to the bottom, press any manual button on both sides of the fire roller shutter, and the fire roller shutter shall be able to rise to the limit position (or drop to the bottom again after a delay). The lifting, lowering and stopping test of the manual buttons on both sides of the fire shutter. The fire rolling shutter shall be able to operate according to the instructions, and the operation shall be stable without blocking, not to mention uneven running speed of the shutter, stacking of the shutter or derailment. Test of manual emergency device. The manual zipper is used to lift the fire shutter, and the manual quick release device is used to lower the fire shutter. The fire shutter shall be able to run smoothly. Simulate the fire signal for linkage test. It is required that the fire shutter should be able to descend according to the normal procedure, and the contents and parts displayed in the fire control room should be consistent with the actual situation. Check whether the sealing of fire shutter is intact and damaged. The inspection above Henan fire rolling shutter door shall be carefully recorded, and the problems found shall be solved in a timely manner without leaving hidden dangers. Check whether the appearance of the fire shutter is intact and whether the curtain surface is damaged. Henan fire shutter door The door leaf of Henan fire shutter door cannot move: sensor failure is the major cause of the fire shutter door leaf cannot move. When such a situation occurs, be sure to check whether the sensor signal light is normal. If it is not the fault of the sensor, it may be that the wire connector is loose, the belt falls off, the controller is burned, the foreign matter is stuck, the voltage is abnormal, and so on. Pay attention to check and eliminate them one by one. Refuge bay door Manufacturer The door leaf of the fire rolling shutter jumps when opening and closing: the reason for this fault is very simple. If the track of the fire rolling shutter is jammed by foreign matters, it is necessary to check the tracks on both sides of the door leaf, remove the foreign matters, and the fault can be solved. The opening and closing speed of the fire shutter door leaf is too slow: customers often hear this situation. It may be that the speed adjustment of the national controller is too slow, or the belt is too loose, resulting in friction between the fire shutter door leaf and the guide rail. When handling, check these two parts. If the speed is too slow, adjust them faster. If the belt is too loose, tighten it in time.

 Chongqing professional refuge door manufacturer

A brief talk on the problems encountered in the fire acceptance of Henan fire rolling shutter door 1. The curtain plate coating falls off and rusts, and the curtain plate has obvious pressure pits, concave convex, and penetrating holes. major Refuge bay door The rolling shutter is a complete fire protection product. If the shutter has problems, it will directly affect the fire resistance limit index of the rolling shutter. 2. The guide rail is deformed and the curtain board is stuck or falls unevenly. The fireproof rolling shutter door generally moves along the guide rail. If the guide rail is twisted or broken, the rolling shutter door will not be able to move to the specified position, which will not achieve the effect of fire separation. 3. On the roller shutter, the lower limit fails or the limit line is wrongly connected. Refuge bay door Manufacturer This often happens on the fire roller shutter of the atrium. Because the fire roller shutter of the atrium is sometimes installed outside the walkway of the upper floor, there is no floor under the roller shutter to close it, and a large gap is leaked, so the fire separation of the upper and lower floors cannot be reached.

 Chongqing professional refuge door manufacturer

The function effect of Henan fireproof rolling shutter door The fireproof rolling shutter door is based on the steel rolling shutter, the transmission parts are modified, equipped with fireproof electrical appliances and other equipment, so as to achieve the fireproof function: the fireproof motor is controlled by the fireproof electric cabinet, and the roller is driven by the speed change device to make the rolling shutter door open and close. In case of power failure, the manual handle on the fireproof motor can also be used to achieve manual operation. major Refuge bay door At the relative movement of the machinery, the coupling is used to replace the sprocket drive, and the friction in the track is inlaid with copper plate or nylon. Refuge bay door Manufacturer It is suitable for the use or storage of combustible gases, volatile chemicals and other high ignition materials in factories and warehouses where there is or may be an explosion of fire hazards. 1. The integrated bus is used internally, and the data transmission is reliable and fast. 2. It has the functions of phase sequence automatic detection, correction and phase loss protection. The standby power of main power supply can be switched automatically (with standby power). 3. With rich reserved interfaces, it can be linked with the fire control center. 4. All electronic learning and memory limit, no matter the upper limit or lower limit positioning will never change. 5. It adopts advanced microcomputer processor technology, which is stable and reliable, without upper limit height range 6. It has smoke and temperature sensing signal synchronization and step by step detection function. 7. The setting of operating parameters is simple, convenient and accurate. 8. It has the function of manual priority escape. In case of three-phase power or main power failure, the controller can automatically lower the roller shutter through the quick release device to close the roller shutter.

 Chongqing professional refuge door manufacturer

The advantages and problems in the development of fire doors in Henan Province Fire doors are more popular in recent years, so how much do you know about the maintenance, advantages and development of fire doors? The following section will provide you with a comprehensive knowledge of fire doors, so that you can better understand fire doors. major Refuge bay door Fireproof door is a kind of movable fireproof partition. In addition to the function of ordinary door, it, together with the frame, can meet the requirements of fire resistance stability and integrity within a certain period of time. It has special functions of fire prevention, smoke separation and high temperature blocking. In case of fire, it should have self closing and signal feedback functions. (1) Advantages of fire doors In case of fire, Henan fire doors and windows can be automatically closed through the linkage control system when they are in the open shoulder state, effectively ensuring the reliable closing of fire door maintenance in the fire, so as to achieve its due role in smoke separation and fire resistance. There is no big difference between the maintenance of fire doors and the maintenance of normally closed fire doors in terms of production and basic configuration, but the door closers for the maintenance of normally closed fire doors are replaced with automatic fire release devices that are linked with the automatic fire alarm. At the same time, they can be installed with the control box produced by the manufacturer. Linkage is achieved by installing smoke detectors and smoke detectors on the left and right sides of the maintenance of fire doors, When the smoke detector detects the smoke signal and sends it to the host computer of the automatic fire alarm linkage control system, the linkage control system transmits 24v power to the fire door maintenance releaser to automatically close the fire door for maintenance. The closing or opening status of the fire door maintenance has signals fed back to the alarm host computer or control box. Refuge bay door Manufacturer The automatic release device for fire door maintenance developed by Dong Shicong of Chengdu Huili University Research Institute can open the fire door maintenance for 0-180 degrees freely and close it smoothly, completely changing the disadvantage of inconvenient use of the normally closed fire door maintenance closer due to its large opening angle of 90 degrees, and once the fire door is closed for maintenance, the release device will not be reset, It has become a movable fire door maintenance that automatically opens, closes, opens and closes, overcoming the contradiction that normally closed fire doors must be manually closed or cannot be closed after being pushed to a certain limit (greater than 90 degrees) for maintenance; The lesson of blood proves that people who escape from a fire simply cannot close the opened fire door for maintenance due to panic and eagerness to escape.

24H

free hotline

0371-85127888 

 Henan Refuge Room Gate

Tel.: 0371-63206926

Email: [email protected]

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City