上海龙凤shlf1314足浴

Hello! Welcome to the website of Henan Rui'andun Door Industry Co., Ltd!

 Henan fireproof door

contact us

Tel.: 0371-85127888

Fax: 0371-62495556

Mobile: 17788121396

Email: [email protected]

website: www.00151.cn

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City

Shangqiu professional steel fireproof rolling shutter door manufacturer

Your current location: home page > Hot information

Shangqiu professional steel fireproof rolling shutter door manufacturer

2023-09-20
 Shangqiu professional steel fireproof rolling shutter door manufacturer

Placement requirements, maintenance methods and precautions of Henan fire door at ordinary times Maintenance methods and precautions of fire door at ordinary times. major Steel fire resistance rolling shutter door When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 2. Do not pull off the fireproof seal, or it will lose its function in case of fire. Henan fireproof doors and windows cannot be left open for a long time, which will damage the door closer and make it lose its function. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 3. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 4. Henan fireproof doors and windows shall be protected from outdoor sunshine for a long time to prevent the fireproof door from being heated. Steel fire resistance rolling shutter door Manufacturer It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. After splashing with water, wipe it with dry cloth to avoid local expansion. The fire door closer must be replaced in case of oil leakage.

 Shangqiu professional steel fireproof rolling shutter door manufacturer

Henan fireproof door is generally set in the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Inspection doors of vertical pipe shafts such as cable shafts, pipe shafts, smoke exhaust ducts, garbage ducts, etc. Henan fire door (3) divides the fire compartment, controls the fire wall and the door on the fire partition of the building area of the compartment. major Steel fire resistance rolling shutter door When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (4) Code (such as GB50016-2014 Code for Fire Protection Design of Buildings) or partition door with special requirements for fire and smoke prevention. For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. Steel fire resistance rolling shutter door Manufacturer There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. Fire and burglar proof doors are often used as household doors in high-rise and high-grade residential buildings. GB 12955-2008 Requirements for Fire Resistance of Fire Doors Fire doors are an important part of fire fighting equipment and an important part of social fire prevention. Fire doors should be equipped with fire door closers or door closers that allow normally open fire doors to automatically close the door leaves in case of fire (except for special parts, such as pipeline shaft doors, etc.). That is to say, except for some special parts, such as pipeline well doors, which do not need to install door closers, other parts need to install fire door closers.

 Shangqiu professional steel fireproof rolling shutter door manufacturer

Can the door of Henan Refuge Room be removed? According to Article 5.5.32 of the Code for Fire Protection Design of Buildings, for residential buildings with a building height of more than 54m, there should be a room that meets the following requirements: it should be set close to the external wall and should be equipped with an openable external window; The fire resistance limit of the inner and outer walls should not be less than 1.00h. The door of the room should be Class B fireproof door, and the fire resistance integrity of the outer window should not be less than 1.00h. major Steel fire resistance rolling shutter door The total net width of each door, emergency exit, evacuation walkway and evacuation staircase of the residential building shall be determined by calculation, and the net width of the door and emergency exit shall not be less than 0.90m, and the net width of the evacuation walkway, evacuation staircase and the first floor evacuation outer door shall not be less than 1.10m. The clear width of the evacuation staircase with railings on one side of the residence with a building height of no more than 18m shall not be less than 1.0m. The relevant requirements of the Code for Fire Protection Design of Henan Refuge Room Door Buildings stipulate that: 1. Evacuation in buildings with Class I and II fire resistance rating] or the linear distance from any point in the auditorium, exhibition hall, multi-function hall, restaurant, business hall, etc. with no less than 2 emergency exits to the nearest evacuation] or the emergency exit shall not be more than 30m. 2. When the evacuation door] cannot directly connect to the outdoor ground or the evacuation staircase, an evacuation corridor with a length of no more than 10m shall be used to connect to the nearest emergency exit. Steel fire resistance rolling shutter door Manufacturer When the place is equipped with automatic sprinkler system, the safe evacuation distance from any indoor point to the near emergency exit can be increased by 25%.

 Shangqiu professional steel fireproof rolling shutter door manufacturer

Henan fire door is an important part of fire fighting equipment. Fire door is an important part of fire fighting equipment and an important part of social fire prevention. Therefore, the quality and use of fire door is the key to the success of fire prevention. major Steel fire resistance rolling shutter door The fire resistance limit of Class C fireproof door is 0.6h) 1. The inspection door on the wall of equipment tube well, ventilation duct and garbage duct shall be Class C fireproof door. 2. The front door of the garbage way shall be Class C fireproof door. 3. When the cable shaft and pipe shaft are set in the front room of the smoke proof staircase and the shared front room, the inspection door on the shaft wall shall be Class C fireproof door. 4. The door connecting the substation and distribution substation should be Class C fireproof door. The door directly leading to the outdoor of the substation shall be Class C fireproof door. 5. The cable well and pipe well shall be separated from each other every 2~3 floors by incombustible materials equivalent to the fire resistance limit of the floor. The inspection door on the shaft wall shall be Class C fire door. 6. The garbage hopper shall be made of incombustible and corrosion-resistant materials and can be closed and sealed by itself; Garbage hoppers of high-rise buildings and super high-rise buildings shall be located in the front room of the garbage chute, which shall be equipped with Class C fireproof doors. 7. The telecommunication room shall adopt outward opening Class C fireproof door with a width of more than 0.7m. 8. The oxygen busbar room with the oxygen delivery capacity not exceeding 60m3/h can be set in the user's workshop with the fire resistance rating not lower than Grade III and close to the external wall. The wall with the height of 2.5m and the fire resistance rating not lower than 1.5h and the Grade C fire door should be used to separate it from other parts of the workshop. 9. The partition wall of the collection warehouse and exhibition room shall be non combustible. The compartments in the fire compartment shall be separated by partition walls with a fire resistance rating of not less than 3h and Class B fire doors. The enclosure structure of closed shaft shall be non combustible and Class C fireproof door. 10. The fire resistance limit of partition walls between production rooms with explosion risk shall not be less than 1.5h. Steel fire resistance rolling shutter door Manufacturer The door is Class C fireproof door. 11. When the oxygen generation station building or liquid oxygen gasification station building and oxygen filling station building are arranged in the same building, the noncombustible partition wall with a fire resistance rating of not less than 1.5h and Class C fire door shall be used, and they shall be connected through the walkway. 12. The doors on the partition walls between the oxygen compressor room and the bottle filling room, as well as the purification room, the oxygen storage bag room, the oxygen storage tank room, the liquid oxygen storage tank room and other rooms shall be Class C fireproof doors.

 Shangqiu professional steel fireproof rolling shutter door manufacturer

Maintenance and cultivation of Henan fire rolling shutter All fire rolling shutters should be checked and tested once a week. The test content includes: fire rolling shutter escape function test. major Steel fire resistance rolling shutter door After the fire roller shutter is in the linkage state and drops to the bottom, press any manual button on both sides of the fire roller shutter, and the fire roller shutter shall be able to rise to the limit position (or drop to the bottom again after a delay). The lifting, lowering and stopping test of the manual buttons on both sides of the fire shutter. The fire rolling shutter shall be able to operate according to the instructions, and the operation shall be stable without blocking, not to mention uneven running speed of the shutter, stacking of the shutter or derailment. Test of manual emergency device. The manual zipper is used to lift the fire shutter, and the manual quick release device is used to lower the fire shutter. The fire shutter shall be able to run smoothly. Simulate the fire signal for linkage test. It is required that the fire shutter should be able to descend according to the normal procedure, and the contents and parts displayed in the fire control room should be consistent with the actual situation. Check whether the sealing of fire shutter is intact and damaged. The inspection above Henan fire rolling shutter door shall be carefully recorded, and the problems found shall be solved in a timely manner without leaving hidden dangers. Check whether the appearance of the fire shutter is intact and whether the curtain surface is damaged. Henan fire shutter door The door leaf of Henan fire shutter door cannot move: sensor failure is the major cause of the fire shutter door leaf cannot move. When such a situation occurs, be sure to check whether the sensor signal light is normal. If it is not the fault of the sensor, it may be that the wire connector is loose, the belt falls off, the controller is burned, the foreign matter is stuck, the voltage is abnormal, and so on. Pay attention to check and eliminate them one by one. Steel fire resistance rolling shutter door Manufacturer The door leaf of the fire rolling shutter jumps when opening and closing: the reason for this fault is very simple. If the track of the fire rolling shutter is jammed by foreign matters, it is necessary to check the tracks on both sides of the door leaf, remove the foreign matters, and the fault can be solved. The opening and closing speed of the fire shutter door leaf is too slow: customers often hear this situation. It may be that the speed adjustment of the national controller is too slow, or the belt is too loose, resulting in friction between the fire shutter door leaf and the guide rail. When handling, check these two parts. If the speed is too slow, adjust them faster. If the belt is too loose, tighten it in time.

 Shangqiu professional steel fireproof rolling shutter door manufacturer

What problems should be paid attention to during the installation of Henan fire door? Henan fire door manufacturers should know that the use performance of fire doors comes from the quality problems of the fire doors themselves on the one hand, and the installation of fire doors on the other hand. If the fire doors are not installed according to the relevant standards, then their fire performance may be affected in the use process. major Steel fire resistance rolling shutter door Here are some precautions for installation. 1. When installing door frames and leaves, attention shall be paid to the opening direction of the door, which must be opened in the direction of evacuation. 2. Stealing work and materials is strictly prohibited. Some construction units speed up construction. There are serious problems of cutting work and materials when installing fire doors. Some do not install door closers or sequencers; Some fire doors should be equipped with 3 hinges, and they only have 2 or 1 hinge; Some fireproof door hinges with 4 screw holes are only installed with 2 screws, reducing the fixing strength; Some even install non fireproof hardware fittings and door locks; Some do not install fireproof sealing strips; Some fireproof doors are equipped with ordinary glass or fireproof glass that exceeds the specified area, etc. It is important to know that these jerry building will be reflected in the use of fireproof doors later. Steel fire resistance rolling shutter door Manufacturer Fire doors have special functions of fire prevention, smoke separation, fire spread suppression and evacuation protection, so they should have good airtightness. Therefore, attention should be paid to some details or sealing problems during installation.

24H

free hotline

0371-85127888 

 Henan Refuge Room Gate

Tel.: 0371-63206926

Email: [email protected]

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City