
What are the functions of the doors of Henan Refuge Room? With the rapid progress of society, in order to improve our fire awareness in life, Henan Refuge Room doors have been used. major Steel fire resistance rolling shutter door So, what are the advantages of this product? Next, let's introduce the door manufacturer of Henan Refuge Room to you. 1、 The basic function of fire shutter is to prevent fire. This is a new type of material. This material has a very high ignition point, so it is not easy to catch fire. It is also very good in use. We can use it with confidence. Such a product can be liked if it performs so well in terms of fire resistance, and its sales volume has also increased greatly. 2、 This product has some effect on thermal insulation, because this material is relatively thick, so there is no problem in thermal insulation. Steel fire resistance rolling shutter door Manufacturer We all know that heat preservation is important in winter, and the heat preservation effect of this product can just meet the needs of winter use.

Henan fire door technical requirements Wooden fire door is a door with certain fire resistance performance, which is made of fire-resistant wood or fire-resistant wood products as door frame, door leaf framework, door leaf panel. If the door leaf is filled with materials, it is filled with fire insulation materials that are non-toxic and harmless to human body, and equipped with fire hardware accessories. major Steel fire resistance rolling shutter door The overlapping size of door leaf and door frame shall not be less than 12mm; The fit clearance between the door leaf and the hinge side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The fit clearance between the door leaf and the locked side of the door frame shall not be greater than the dimensional tolerance specified in the design drawings; The clearance between the door leaf and the upper frame shall not be greater than 3mm; The gap between two or more door leaves shall not be greater than 3mm; The movable clearance between the door leaf and the lower frame or ground shall not be greater than 9mm; The gap between the door leaf and the door frame binding surface: the gap between the door leaf and the binding surface of the door frame on the hinge side, the lock side and the upper frame shall not be greater than 3mm; The plane height difference between the door leaf and the door frame: On the opening surface of the fire door, the plane height difference between the door frame and the door leaf of Tianjin Telescopic Barcode Reader should not be greater than 1mm. Wooden fireproof door refers to the door frame, door leaf framework and door leaf panel made of wood or wood products, and the fire resistance limit of the door reaches the specified value. Some small deviations between wooden fireproof doors cannot be wrong. Maybe it is a small detail problem that may fail to meet the standard. Steel fire resistance rolling shutter door Manufacturer The materials used for Henan fire door are compared first. The fire door has a simple structure and is mainly composed of four parts: door closer, door panel materials (including 06 and 08), door frame materials, and fire panels. Grade A fireproof door is generally made of 08 material with good quality. Its normal service life is 5-8 years. The iron material of the door panel is thick. For the fireproof door with the same thickness, the weight of Grade A fireproof door is greater than that of Grade B.

Henan fireproof door installation method The fireproof door is divided into steel fireproof door and wooden fireproof door according to the material. There are some differences in the installation method of the two fireproof doors. major Steel fire resistance rolling shutter door The fire rating is slightly different. You must pay attention to the details when installing. First of all, when installing the wooden fireproof door, the size of the door frame should be 20mm smaller than the opening, and the lower foot of the door frame should be buried 20mm below the ground. The door frame should be firmly fixed with the wall, and perpendicular to the corner. The vertical frame and bracing frame shall be straight and at the same angle to avoid planing and sawing. There shall be no less than 3 fixed points on both sides of the door frame, and the spacing shall not be greater than 800mm. Secondly, during the installation of the steel fire door, considering the bending deformation of the door frame, it is necessary to support the door frame with wooden braces in the width direction of the door frame. The lower foot of the door frame is buried 20 mm below the ground, and then the door frame is welded with the embedded parts on the wall. Then make a hole in the wall at the upper corner of the door frame, and pour concrete of cement, sand and expanded perlite (1:2:5), which can be used after the concrete has set. Steel fire resistance rolling shutter door Manufacturer Requirements for airtightness of fire doors: there are clear requirements for the size of the gap at each overlap of fire doors: for steel fire doors, the overlap between the leaf and the door frame shall not be less than 10mm, and the gap between the leaf and the door frame on both sides shall not be more than 4mm. The gap after the installation of the fire door cannot be too large, otherwise the airtightness of the fire door is difficult to guarantee, and it is difficult to reflect its role in restraining fire and smoke spread under fire conditions.

Henan fire door selection method Fire door is particularly important as a family fire protection, but when you buy low-quality fire door, the fire door is no longer fireproof, what should you do? The fire department of our city investigated and destroyed a batch of inferior fire doors with honeycomb paper instead of fireproof filler materials. Here, the firefighters introduced some tips on how to select and purchase high-quality fire doors. According to the regulations, steel and wood fire doors can be divided into Class A, Class B and Class C according to the fire resistance limit. The fire resistance limit requirements are 90 minutes, 60 minutes and 30 minutes respectively. In addition, the wood used to make wood fire doors needs drying and flame retardant treatment, and the hardware used must also be fire hardware. major Steel fire resistance rolling shutter door There are five ways to choose high-quality fire doors: one is to check the appearance, high-quality steel fire doors are firmly welded, and the welding spots are evenly distributed; The external surface shall be sprayed flat and smooth; There shall be product mark, quality inspection mark and quality certification (approval) mark at the specified position. Steel fire resistance rolling shutter door Manufacturer The qualified wooden fireproof door shall be intact without damage, and the surface shall be clean without plane marks, burrs and hammer marks; Corner cutting and butt joint shall be tight and flat. The second way is to check the figures. The overall dimensions of qualified products should be less than or equal to the overall dimensions in the sample description, the door leaf thickness should be greater than or equal to the door leaf thickness in the sample description, the door frame sidewall width should be greater than or equal to the door frame sidewall width in the sample description, and the overall dimensions of fire-resistant glass should be less than or equal to the overall dimensions of fire-resistant glass in the sample description, The thickness of fireproof glass shall be equal to or greater than the thickness of fireproof glass in the sample description.

What is the difference between the normally open and normally closed fire doors of Henan fire doors? The differences between the normally open and normally closed fire doors are as follows: 1. Different meanings. The normally open fire doors are usually open, and they are automatically closed by the control system only in case of fire. It is generally used in the passage or corridor of public places. major Steel fire resistance rolling shutter door Normally closed fire doors are closed under normal conditions and in case of fire, and need to be pushed open when someone walks around, so as to prevent smoke and fire and prevent the spread of fire. 2. The price is different, and the price of the normally open fire door is higher, and the system is strong. The price of normally closed fire doors is relatively low. Henan fireproof doors and windows 3. The composition is different. The normally open fireproof door consists of door leaf, door frame, door closer, sealing strip, release switch and other parts. The normally closed fireproof door is equipped with sequencer in addition to the above parts. 4. The control mode is different. The normally open fire door is controlled by the fire door release switch. The normally closed fire door does not need to be set with electric automatic control. It is mainly closed by the door closer and sequencer, that is, mechanical. Precautions for Henan fire door fire door 1. The fire door shall be installed according to the type of fire door used, and the appropriate installation method shall be adopted. 2. The door frame of the fire door can be fixed with the wall by expansion bolts, or iron parts can be embedded at the opening when building the wall, and welded firmly with the door frame connector during installation. 3. No matter what kind of connection mode is used between the door frame and the wall, there should be no less than 3 anchor points on each side, and they should be firmly connected. Henan fireproof doors and windows 4. When installing the fireproof door, it should be aligned and hoisted. After the size is appropriate, it should be temporarily fixed, corrected and adjusted, and then it can be connected and anchored. 5. The sliding door shall be flexible after installation; The side hung door is easy to open and tight and firm to close. Steel fire resistance rolling shutter door Manufacturer Henan fireproof doors and windows 6. Door closers must be installed on fireproof doors, and sequencers must be installed on opposite doors. 7. The handle, fire lock and other hardware accessories on the fire door must be complete. 8. It is required that the clearance from the ground plane shall not be greater than 5mm.