Henan fireproof rolling shutter door maintenance common faults and treatment methods The fireproof rolling shutter door is constantly applied to large supermarkets, shopping malls, underground garages, workshops and other crowded places. It is inevitable that there will be some small problems that need to be solved. I summarize a few points for your reference. 1、 The fire shutter door does not act: first, check the power supply to see if the power supply air switch of the fire shutter door has power. If there is no power, check the power supply. If there is power, the power indicator of the roller shutter control box should be green at this time. major fire-proof anti-theft door If the indicator light is not on, then we should check whether the transformer in the control box (the resistance of the transformer is 270 ohms) is burned out. If the power indicator flashes green, it indicates that the power supply may be out of phase. If the power supply is not out of phase, it may be that the standby power board of the control box is burned out; It is also possible that both the power board and the standby power board are burned out. 2、 Henan fire shutter door power supply air switch cannot be pushed up: when delivering the gate, the air switch cannot be pushed up, first check whether there is a problem with the standby board, and the resistance of the output line of the standby board is about 300 ohms. In case of open circuit or short circuit, check whether the motor brake is burnt or whether the spare board is burnt. 3、 The operation button does not work properly: you should first press the Stop key, then press the Reset key, and then press the Up and Down keys. 4、 The indicator lights of the power control box or button panel are all on: at this time, first check whether there is a short circuit in the button line or a button may be pressed to death. If the above phenomenon does not exist, it may be that the chip on the power main board is broken, and then replace the chip. fire-proof anti-theft door direct deal Pay attention to wearing the clothes in reverse (that is, the opening faces the opening).

Henan fire rolling shutter door is generally installed in the place determined by the process. In addition to the firewall, the fire rolling shutter door should be installed in the two fire compartments where there is no firewall. It is generally located at the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Divide the fire compartment and control the fire wall and the door on the fire partition in the building area of the compartment. When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (3) Code (such as GB50045-95 Code for Fire Protection Design of High rise Civil Buildings) or partition door with special requirements for fire and smoke prevention. major fire-proof anti-theft door For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. fire-proof anti-theft door direct deal The limited area of Henan fire shutter door special grade fire shutter In the use of special grade fire shutter, because it is mainly used in the rapid formation of fire separation areas, and is mostly set in applications with large space, as a visible fire separation device, generally in the production of fire shutter, fire shutter will be painted with a more striking color, It can not only make the fireproof rolling shutter have a better decorative effect after being folded, but also can remind people of the escape route in fire accidents through eye-catching and penetrating colors in the fire compartment, so as to buy time for effective escape.

The conditions for the developer of the Henan Refuge Room Door to deliver the house must be met when delivering the house in the new fire prevention code: legal conditions: 1. The developer should provide the Construction Project Completion Filing Form, household acceptance form, area report measurement report and indoor environment inspection report; the real estate development enterprise should obtain the Construction Project Completion Acceptance Filing Form when delivering the pre-sale commercial house; Obtain the technical report on the actual measurement of commercial housing area; Meet other delivery conditions agreed in the pre-sale contract. 2. The developer shall provide the Housing Quality Assurance Certificate and the Housing Operation Manual: the developer must provide the above two books when delivering the new commercial residential buildings for sale. major fire-proof anti-theft door If the developer cannot provide any of the above materials, the owner has the right to refuse to accept the house. fire-proof anti-theft door direct deal Agreed conditions: 1. According to the house purchase contract, the developer shall fulfill the delivery commitment for water supply, power supply, heat supply, gas, communication, roads, greening and other supporting facilities when delivering the house, otherwise, the owner has the right to refuse to accept the house. 2. Other conditions agreed in the housing contract

Placement requirements, maintenance methods and precautions of Henan fire door at ordinary times Maintenance methods and precautions of fire door at ordinary times. major fire-proof anti-theft door When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated. 2. Do not pull off the fireproof seal, or it will lose its function in case of fire. Henan fireproof doors and windows cannot be left open for a long time, which will damage the door closer and make it lose its function. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose. 3. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function. 4. Henan fireproof doors and windows shall be protected from outdoor sunshine for a long time to prevent the fireproof door from being heated. fire-proof anti-theft door direct deal It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation. 5. Keep the indoor air circulation and prevent the fire door from frequent damp. After splashing with water, wipe it with dry cloth to avoid local expansion. The fire door closer must be replaced in case of oil leakage.

The advantages and disadvantages of the products of Henan fire rolling shutter manufacturers The fire rolling shutter is usually located at the poor entrance of the building, which plays a role in fire prevention, heat insulation and smoke dispersion. The fireproof rolling shutter door is a useful time to isolate the fire source when a fire occurs and provide a useful escape for employees. major fire-proof anti-theft door However, the inferior fire rolling shutter door will not only not intercept the fire source, but also increase the fire. Therefore, the advantages and disadvantages of the fire rolling shutter door are also quite important. Henan fire rolling shutter door The rolling shutter door will stop landing when landing to the required height, which is to avoid people who have not had time to escape being trapped inside the rolling shutter door. fire-proof anti-theft door direct deal If the inferior rolling shutter doors were all lowered, the surviving victims would be trapped inside and become unnecessary casualties. Recommended reading: The fire hour and temperature resistance limit of some fire rolling shutter doors are strictly defined in the fire rolling shutter door specification. Therefore, excellent guaranteed fire rolling shutter doors must be used when adopting and purchasing rolling shutter doors.

The installation and installation of Henan fireproof rolling shutter door requires that the fireproof rolling shutter door is widely used in shopping malls, shopping malls and underground garages, but the specific installation steps should not mention laymen. major fire-proof anti-theft door Even the fireproof rolling shutter door can not be explained in detail. The following is a detailed description of the installation of Henan fireproof rolling shutter door step by step: step 1: install the guide rail. 1. Determine the installation position of the guide rail on both sides of the fireproof rolling shutter door, set out the guide rail reference line with hammer line, and set out the cross line of the fixing bolt of the guide rail connector. The guide rail is not less than 75cm above the ceiling. 2. Punch the holes for fixing expansion bolts of connectors on the wall column with a percussion drill. The spacing between connectors shall not be more than 600mm, and both ends shall be 100mm away from the guide rail opening. Fix several connecting pieces up and down first, stick the guide rail, correct its verticality and spot weld it, and then repeat the verticality of the guide rail after fixing the guide rail. The verticality of each meter shall not exceed 5mm, and the verticality of the whole length shall not exceed 20mm. The depth of the composite curtain embedded in the guide rail (see GBl4102-2005). 3. Install the rest of the connecting pieces. Spot welding shall be adopted between the connecting piece and the guide rail. The spot welding points between each connecting piece and a guide rail shall not be less than 5 points, and the width of the spot welding shall not be less than 5mm. The welding point shall never be penetrated. fire-proof anti-theft door direct deal Stainless steel welding rod shall be used when stainless steel guide rail is used.