Henan fire rolling shutter door is generally installed in the place determined by the process. In addition to the firewall, the fire rolling shutter door should be installed in the two fire compartments where there is no firewall. It is generally located at the following parts. (1) Close the evacuation staircase to the walkway; Enclose the elevator hall, the door leading to the front room and the front room leading to the walkway. (2) Divide the fire compartment and control the fire wall and the door on the fire partition in the building area of the compartment. When it is difficult to set firewall or fire door in the building, fire rolling shutter door shall be used instead, and water curtain shall be used for protection. (3) Code (such as GB50045-95 Code for Fire Protection Design of High rise Civil Buildings) or partition door with special requirements for fire and smoke prevention. supply fire resistance steel door For example, the partition doors of equipment rooms (cylinder rooms, foam stations, etc.) attached with fixed fire extinguishing devices in high-rise civil buildings, ventilation, air conditioning rooms, etc. should be Class A fireproof doors; The door on the partition wall of the basement room where people often stay or there are many combustibles shall be Class A fireproof door; Due to limited conditions, it is necessary to arrange oil fired and gas-fired boilers, oil immersed power transformers, high voltage capacitors and switches filled with oil, etc. in high-rise buildings. The doors on the partition walls of special rooms should be Class A fireproof doors. There are also household doors with special requirements that must be fireproof, such as fire control command center, archives room, valuables warehouse, etc., which usually use Class A or Class B fireproof doors. fire resistance steel door Manufacturer The limited area of Henan fire shutter door special grade fire shutter In the use of special grade fire shutter, because it is mainly used in the rapid formation of fire separation areas, and is mostly set in applications with large space, as a visible fire separation device, generally in the production of fire shutter, fire shutter will be painted with a more striking color, It can not only make the fireproof rolling shutter have a better decorative effect after being folded, but also can remind people of the escape route in fire accidents through eye-catching and penetrating colors in the fire compartment, so as to buy time for effective escape.

Henan fireproof rolling shutter door is developing rapidly. Henan fireproof rolling shutter door style and measurement design considerations. The fireproof rolling shutter door is widely used in commercial buildings, workshops and underground garages. The specific installation standards are as follows: measurement design: step one: general classification of roller shutter installation. Self inspection of fire shutter: manual operation mode: whether a circular iron chain set in the storage box at one side of the shutter can be found to operate the lowering and rolling. supply fire resistance steel door When the installation form is wall side installation: when there are embedded parts (steel plates) in the building, after cleaning the installation datum plane, check and verify whether the size and external position of the embedded parts are suitable for the installation drawing design. If the design requirements are appropriate, this is the datum plane for the installation of large and small supports. fire resistance steel door Manufacturer The facing bricks around the wall projections shall be cut and matched with the whole brick, and the edges shall be clean. (Check the date of delivery and the date of maintenance; carbon dioxide, dry powder and clean gas extinguishers are outdated if they have been delivered for 5 years or maintained for 2 years; foam extinguishers are outdated if they have been delivered for 3 years or maintained for 1 year, and they need to be sent to the fire extinguisher factory or professional maintenance unit for maintenance). Henan fireproof rolling shutter door After the Henan fireproof rolling shutter door is installed, the ceiling edge should be 50mm away from the curtain plate to avoid friction; c. The foundation dimensions of rolling shutter doors and parts shall be measured, which shall be consistent with the requirements of the design institute.

Henan fire door is an important part of fire fighting equipment. Fire door is an important part of fire fighting equipment and an important part of social fire prevention. Therefore, the quality and use of fire door is the key to the success of fire prevention. supply fire resistance steel door The fire resistance limit of Class C fireproof door is 0.6h) 1. The inspection door on the wall of equipment tube well, ventilation duct and garbage duct shall be Class C fireproof door. 2. The front door of the garbage way shall be Class C fireproof door. 3. When the cable shaft and pipe shaft are set in the front room of the smoke proof staircase and the shared front room, the inspection door on the shaft wall shall be Class C fireproof door. 4. The door connecting the substation and distribution substation should be Class C fireproof door. The door directly leading to the outdoor of the substation shall be Class C fireproof door. 5. The cable well and pipe well shall be separated from each other every 2~3 floors by incombustible materials equivalent to the fire resistance limit of the floor. The inspection door on the shaft wall shall be Class C fire door. 6. The garbage hopper shall be made of incombustible and corrosion-resistant materials and can be closed and sealed by itself; Garbage hoppers of high-rise buildings and super high-rise buildings shall be located in the front room of the garbage chute, which shall be equipped with Class C fireproof doors. 7. The telecommunication room shall adopt outward opening Class C fireproof door with a width of more than 0.7m. 8. The oxygen busbar room with the oxygen delivery capacity not exceeding 60m3/h can be set in the user's workshop with the fire resistance rating not lower than Grade III and close to the external wall. The wall with the height of 2.5m and the fire resistance rating not lower than 1.5h and the Grade C fire door should be used to separate it from other parts of the workshop. 9. The partition wall of the collection warehouse and exhibition room shall be non combustible. The compartments in the fire compartment shall be separated by partition walls with a fire resistance rating of not less than 3h and Class B fire doors. The enclosure structure of closed shaft shall be non combustible and Class C fireproof door. 10. The fire resistance limit of partition walls between production rooms with explosion risk shall not be less than 1.5h. fire resistance steel door Manufacturer The door is Class C fireproof door. 11. When the oxygen generation station building or liquid oxygen gasification station building and oxygen filling station building are arranged in the same building, the noncombustible partition wall with a fire resistance rating of not less than 1.5h and Class C fire door shall be used, and they shall be connected through the walkway. 12. The doors on the partition walls between the oxygen compressor room and the bottle filling room, as well as the purification room, the oxygen storage bag room, the oxygen storage tank room, the liquid oxygen storage tank room and other rooms shall be Class C fireproof doors.

The introduction of Henan fire rolling shutter door is a kind of fire prevention and heat insulation facilities suitable for large openings of buildings. The product has played a certain role in the design and installation of technology. supply fire resistance steel door Fire resistant rolling shutter doors are widely used in the fire partition area of industrial and civil buildings, which can effectively prevent the spread of fire and ensure the safety of life and property. They are indispensable fire prevention facilities in modern buildings. Installation requirements and instructions for fire shutter door 1. The upper part of the opening where the shutter door is installed shall not be equipped with ventilation pipes, water pipes, etc; 2. After the roller shutter door is installed, install the suspended ceiling. The edge of the suspended ceiling should be 50mm away from the curtain plate to avoid friction; 3. During commissioning and use, it is strictly prohibited to stand at the bottom. fire resistance steel door Manufacturer Electrical facilities shall not be removed without authorization; 4. According to the fire management regulations, the chain lubricating oil of the starting motor must not be missed during the routine fire safety inspection every quarter, which is also an important part of the omission of many property management units or fire protection units during the inspection.

What problems should be paid attention to during the installation of Henan fire door? Henan fire door manufacturers should know that the use performance of fire doors comes from the quality problems of the fire doors themselves on the one hand, and the installation of fire doors on the other hand. If the fire doors are not installed according to the relevant standards, then their fire performance may be affected in the use process. supply fire resistance steel door Here are some precautions for installation. 1. When installing door frames and leaves, attention shall be paid to the opening direction of the door, which must be opened in the direction of evacuation. 2. Stealing work and materials is strictly prohibited. Some construction units speed up construction. There are serious problems of cutting work and materials when installing fire doors. Some do not install door closers or sequencers; Some fire doors should be equipped with 3 hinges, and they only have 2 or 1 hinge; Some fireproof door hinges with 4 screw holes are only installed with 2 screws, reducing the fixing strength; Some even install non fireproof hardware fittings and door locks; Some do not install fireproof sealing strips; Some fireproof doors are equipped with ordinary glass or fireproof glass that exceeds the specified area, etc. It is important to know that these jerry building will be reflected in the use of fireproof doors later. fire resistance steel door Manufacturer Fire doors have special functions of fire prevention, smoke separation, fire spread suppression and evacuation protection, so they should have good airtightness. Therefore, attention should be paid to some details or sealing problems during installation.