上海龙凤shlf1314足浴

Hello! Welcome to the website of Henan Rui'andun Door Industry Co., Ltd!

 Henan fireproof door

contact us

Tel.: 0371-85127888

Fax: 0371-62495556

Mobile: 17788121396

Email: [email protected]

website: www.00151.cn

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City

Maintenance methods and precautions of fire door

Your current location: home page > News Center > Industry News

Maintenance methods and precautions of fire door

2020-01-08 15:04:53
second

Maintenance methods and precautions of fire door




Maintenance methods and precautions of fire door:



 Henan fireproof door

1. The door leaf and door frame shall be laid flat and stacked with a backing plate indoors, and the frame and door leaf shall be stacked separately.


2. It is strictly prohibited to store together with acid-base substances. The room should be clean, dry and ventilated.


3. It shall be stored in the room with backup frame and separated from the heat source to avoid thermal deformation.


4. Try to avoid outdoor sunshine for a long time to prevent the fire door from being heated.


5. Keep the indoor air circulation and prevent the fire door from frequent damp. After splashing with water, wipe it with dry cloth to avoid local expansion.


6. To prevent the fire door from being hit abnormally, it is not advisable to use excessive force or open the door at an excessive angle.


7. It is not allowed to hit the door body with sharp tools and heavy objects to prevent the door body from being sunken, scratched and peeling off the paint film.


8. The concealed bolt of the upper and lower fire door shall not protrude when the door is open, so as not to collide with the door frame, deform or fall off and lose its function.


9. Do not support the door for a long time without closing it, which will damage the door closer and make it lose its function.


10. Do not pull off the fireproof seal, or it will lose its function in case of fire.


11. Check every three months to ensure that the fixing screws of hinges, door locks and door closers are not loose.


12. When the hinge makes abnormal noise, add a few drops of lubricating oil to the hinge shaft.


13. The fire door closer must be replaced in case of oil leakage.



Then, the Henan Fireproof Doors and Windows Editor summarized the above contents into the following points, and you must remember!




Do not always open: it is prohibited to manually keep the normally closed fire doors set on the evacuation walkway, the front room of the smoke proof staircase or the shared front room open during the use process to become "normally open" fire doors. In case of a fire, such "normally open" fire doors can not prevent smoke and fire;


Regular inspection: frequently check the integrity of the fire door, check whether the door closer and sequencer are in good use, whether the fire door can be closed automatically in order, and whether the screws on the hinge and hinge are loose. If damaged, immediately organize maintenance;


Decoration: one-sided pursuit of decoration effect, canceling the fire door frame and setting only the door pocket made of ordinary wood, replacing the original frame of the door leaf with other materials, and adding decorative surface layer in a large range, thus damaging the fire retardant coating and failing to achieve fire retardant effect;


Regular test: the normally open fire door shall be tested regularly to check whether its self closing control system, door closer, sequencer, release switch and other aspects are easy to use, whether it can effectively perform the self closing function in case of fire, and at the same time, it is necessary to resolutely prevent the random stacking of articles near the normally open fire door.


Recent browsing:

24H

free hotline

0371-85127888 

 Henan Refuge Room Gate

Tel.: 0371-63206926

Email: [email protected]

Address: West side of South Road, Beida Fuzhong, Baqian Township, Xinzheng City